• 제목/요약/키워드: Power-Bus

검색결과 1,397건 처리시간 0.035초

Redundant Operation of a Parallel AC to DC Converter via a Serial Communication Bus

  • Kanthaphayao, Yutthana;Kamnarn, Uthen;Chunkag, Viboon
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.533-541
    • /
    • 2011
  • The redundant operation of a parallel AC to DC converter via a serial communication bus is presented. The proposed system consists of three isolated CUK power factor correction modules. The controller for each converter is a dsPIC30F6010 microcontroller while a RS485 communication bus and the clock signal are used for synchronizing the data communication. The control strategy of the redundant operation relies on the communication of information among each of the modules, which communicate via a RS485 serial bus. This information is received from the communication checks of the converter module connected to the system to share the load current. Performance evaluations were conducted through experimentation on a three-module parallel-connected prototype, with a 578W load and a -48V dc output voltage. The proposed system has achieved the following: the current sharing is quite good, both the transient response and the steady state. The converter modules can perform the current sharing immediately, when a fault is found in another converter module. In addition, the transient response occurs in the system, and the output voltages are at their minimum overshoot and undershoot. Finally, the proposed system has a relatively simple implementation for the redundant operation.

전압붕괴 임계점 계산을 위한 효율적 통합법 (An Efficient Unified Method to Compute Voltage Collapse Point)

  • 남해곤;김동준;송충기;문영환;김태균;이효상
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권8호
    • /
    • pp.951-957
    • /
    • 1999
  • The saddle node bifurcation (SNB) and the distance voltage instability are valuable information in power system planning and operation. This paper presents a new efficient, robust and unified strategy to compute the SNB by the combined use of the continuation power flow (CPF), Point of Collapse (PoC) method, and the method of a pair of multiple load flow solutions (PMLFS) with Lagrange interpolation utilizing only their advantages: the approximate nose curves and critical loading are determined fast by Lagrange-interpolating two stable and two unstable solutions obtained by using the robust CPF and PMLFS; the exact SNB is computed by the quadratically converging PoC method. The proposed method has been tested on Klos-Kerner 11-bus, New England 30-bus, IEEE 118-bus and KEPCO 791-bus systems. The method is found to be so efficient that computation time for determining the SNB of the KEPCO 791-bus system is 17.82 sec by a notebook PC with 300 MHz Pentium processor.

  • PDF

전력계통의 사고전류 저감 설비별 특성 비교 (Comparison of Fault Current Limiting Characteristics According to Facility in Power System)

  • 박형민;최효상;조용선;임성훈;황종선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.127-129
    • /
    • 2005
  • We investigated the fault current limiting characteristics according to the various facilities in power system. Power systems are becoming larger and larger for meeting electric power demand. Therefore, the over-currents resulting from contingencies such as short circuits are increasing higher, which causes the ratings of circuit breakers(CBs) to increase. Upgrading or replacement of CBs is not difficult from the technical and economical point of view. Bus split is being adopted into a part of 154 kV power systems, but it has adverse effects such as overload to neighboring power systems, increased voltage fluctuation, and decreased power system stability. For 345 kV power systems, the bus split measure is not feasible and dc reactors are being suggested. The superconducting fault current limiter is a protection gear of new concept that limits fault current automatically in a few milliseconds. It can also provide the effect of CB capacity increase, relaxation of power machine criteria, enhancement in power system reliability, and flexible power system operation.

  • PDF

무효전력 흐름 추적을 이용한 무효전력 취약지역 판단 (Reactive Power Traceable System based Vulnerable Areas Detection for Reactive Power)

  • 최윤혁;배문성;이병준
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1145-1153
    • /
    • 2015
  • The paper analyzes reactive power flow characteristic in power system by reactive power tracing. In addition, virtual buses are inserted in the algorithm to consider losses of transmission lines, and shunt capacitor treated as a reactive power generator. The results of simulation are analyzed by two points of view. The one is load’s point of view and another is generator’s point of view. Classic purpose of the reactive power tracing consists in the reactive power pricing. However, it is significantly used to select vulnerable area about line outage in this paper. To find the vulnerable area, reactive power tracing variations between pre-contingency and post-contingency are calculated at all load buses. In heavily load area, buses which has highest variation become the most vulnerable bus. This method is applied to the IEEE 39-bus system. It is compared with voltage variation result and VQ-margin to verify its effect.

터치스크린 컨트롤러용 저면적, 저전력, 고속 128Kb EEPROMIP 설계 (Design of a Small-Area, Low-Power, and High-Speed 128-KBit EEPROM IP for Touch-Screen Controllers)

  • 조규삼;김두휘;장지혜;이정환;하판봉;김영희
    • 한국정보통신학회논문지
    • /
    • 제13권12호
    • /
    • pp.2633-2640
    • /
    • 2009
  • 본 논문에서는 터치스크린 컨트롤러용 IC를 위한 저면적, 저전력, 고속 EEPROM 회로 설계기술을 제안하였다. 저면적 EEPROM 기술로는 SSTC (Side-wall Selective Transistor Cell) 셀을 제안하였고 EEPROM 코어회로에서 반복되는고전압 스위칭 회로를 최적화하였다. 저전력 기술은 디지털 Data Bus 감지 증폭기 회로를 제안하였다. 그리고 고속 EEPROM 기술로는 Distributed DB 방식이 적용되었으며, Dual Power Supply를 사용하여 EEPROM 셀과 고전압 스위칭 회로의 구동전압은 로직전압 VDD(=1.8V)보다 높은 전압인 VDDP(=3.3V)를 사용하였다. 설계된 128Kb EEPROMIP(Intellectual Property)의 레이아웃 면적은 $662.31{\mu}m{\times}1314.89{\mu}m$이다.

다목적 실용위성 전력조절기 모듈화 구현을 위한 새로운 전원단 설계 및 해석 (A new power-stage design and analysis to modularize power regulator of the KOrea Multi-Purpose SATellite)

  • 박성우;이재승;이종인;윤정오
    • 한국산업정보학회논문지
    • /
    • 제8권2호
    • /
    • pp.84-91
    • /
    • 2003
  • 다목적 실용위성(KOMPSAT) 시리즈는 버스전압이 배터리 전압과 동일하며, 전력조절기(power regulator)의 스위칭 듀티 값(duty-ratio)이 위성탑재 소프트웨어에 의해서 제어되는 소프트웨어 제어방식의 비 조절형 버스 시스템(unregulated bus system)을 사용한다. 본 논문에서는 이와 같은 소프트웨어 제어방식의 비 조절형 버스 시스템의 전력조절기 모듈화에 적용 가능한 새로운 전원단 회로를 제안하며, 제안된 전원단의 모드별 동작 특성을 해석한다. 다음으로 컨버터 병렬동작에서 발생할 수 있는 모듈간 전류 불균형(current unbalance)에 대한 제안된 전원단의 타당성을 검증하기 위해 제안된 전원단을 적용한 병렬모듈 컨버터의 prototype제작하여 모듈별 전류 분배(current sharing) 특성을 시뮬레이션 결과와 비교 검토한다.

  • PDF

Power Islands의 공진에 의한 잡음 전달 개선 방법 (The Improvement Method of Transfer Noise by Power Islands Resonace)

  • 이신영;권덕규;이해영
    • 마이크로전자및패키징학회지
    • /
    • 제10권1호
    • /
    • pp.13-18
    • /
    • 2003
  • 본 논문에서는 파워 아일랜드(power island)에서 발생되는 잡음 전달을 개선하는 방법에 대해서 연구하였다. 일반적으로 파워 아일랜드는 각 파워 버스(power bus)의 구조적 공진에 의해 잡음 전달이 증가하는 단점이 있다. 따라서 본 논문에서는 두 가지의 잡음 전달 개선 방법을 제시하였다. 첫 번째로 잡음원의 위치를 변화시킴으로서 구조적 공진을 억제하였다. 두 번째로 공진이 발생할 경우 잡음 전달을 감소시키기 위해서 EGI(Elevated Ground Island)를 제안하였다. 해석결과, 잡음원의 위치에 따라 파워 버스의 공진을 최소로 감소시켰으며, EGI를 이용하여 잡음 전달을 효과적으로 감소할 수 있었다.

  • PDF

전력계통과부하 자동예방법에 관한 연구 (Automatic Suppression of Power System Overload)

  • 박영문;양흥석;문영현
    • 전기의세계
    • /
    • 제27권1호
    • /
    • pp.56-63
    • /
    • 1978
  • A new method is suggested for the bus active power vs. line power flow sensibility bector, applying the Optimally-Ordered Triangular Factorization Technique, and new algorithms are derived for the optimum measures against overloaded lines and transformers resulting from contingency analysis. According to the algorithms an online-purpose FORTRAN computer program package is developed and tested or the actual 48-bus, 91-line power system with good results.

  • PDF

상정사고를 고려한 최적조류계산 연구 (Study on the Security-Constrained Optimal Power Flow)

  • 최길;원종률
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.381-383
    • /
    • 2002
  • This paper proposes a MATLAB program for solving security-constrained optimal power flow using linear programming. Security-constrained optimal power flow can find an optimal generation satisfying bus voltage limits, line flow limits, reactive generation limits, even if contingency occurs. Sensitivity matrixes are obtained based on power flow solutions with and without single line contingency. This program is tested for an IEEE 14bus system with 5 generators Results shows good ability of finding optimal solution in case of a single line contingency.

  • PDF

Active/Reactive Compound Compensation in Distribution System

  • Sul, Yong-Tae
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권4호
    • /
    • pp.46-52
    • /
    • 1997
  • In this paper th use of compensation based on a combination of active plus reactive power at distribution model system is proposed. The basic voltage-power relationships for the linearized case on an infinite bus are used and the compensation angle is defined based on the voltage magnitude response to small power injection. Compensation is supplied at several locations, and the system is subjected to varying fault scenarios, with its response observed under different system conditions. As number of control issues for a storage-based active/reactive power compensator as a bus voltage regulator are explored to compare the effectiveness of active/reactive again reactive-only compensation.

  • PDF