• Title/Summary/Keyword: Power unbalance

Search Result 389, Processing Time 0.028 seconds

Study on the Fracture of Automotive Clutch Disk due to Abnormal Vibration (자동차 클러치 디스크의 불규칙 진동에 의한 디스크 파손 연구)

  • Cho, Chong-Du;Lee, Heung-Shik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.556-561
    • /
    • 2006
  • In this study, the failure of the automotive clutch disk was investigated. During the process of power transmission, clutch disk plates did repeated work of releasing and engaging the pressure plate. The effects of unbalance rotation in the abnormal vibration and torque amplitude under engaged state were measured from this experiment. In order to reduce the unbalance, a modified clutch disk shape was developed. With a three-dimensional model of the stopper pin, to predict fatigue fracture, finite element analysis was carried out and evaluated the improvement of the new clutch disk.

  • PDF

A case Study for Protection Relay System of small Cogeneration intertie (단순병렬 자가발전 설비 보호방식 검토 사례)

  • Lee, S.J.;Kim, K.S.;Yoon, K.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.234-236
    • /
    • 2002
  • The Co-Gen System which maximize energy efficiency was installed at the industrial plants at the initial stage. However Small Scale Co-Gen System was expanded even to the general end-users such as housing and building owing to ESCO business recently. For this SSC, inter-connected operation to the utility is desirable due to voltage and frequency fluctuation following to unbalance between power output and load. Then voltage unbalance with utility system, frequency, increase of short circuit capacity, reclosing, and ALTS etc. should be fully considered for the inter-connected operation. Voltage variation, protection coordination, Co-Generators single running, and short circuit capacity should also be solved. To research the method and solve the problems through the field test and application, we study individual customers Co-Gen System as a case study.

  • PDF

Dynamic Analysis of Rotor Eccentricity in Switched Reluctance Motor with Parallel Winding

  • Li, Jian;Choi, Da-Woon;Cho, Yun-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.85-87
    • /
    • 2008
  • This paper presents dynamic characteristics in Switched Reluctance Motor (SRM) with rotor eccentricity and proposes the reduction method of rotor eccentricity effects by the different winding connections. These characteristics investigations are computed by 2D transient magnetic FEM analysis coupled with external circuits. The radial and unbalance magnetic force in the stator, which is the main exciting force of the vibration, is calculated using Maxwell stress method and compared with the performance characteristics according to the serial and parallel connections of windings. The influence of winding method counteracting unbalance forces on the rotor vibration behavior is estimated by the current waveforms of the paralleled paths under rotor eccentricity.

  • PDF

Detection of Input Voltage Unbalance in Induction Motors Using Frequency-Domain Discrete Wavelet Transform

  • Ghods, Amirhossein;Lee, Hong-Hee;Chun, Tae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.522-523
    • /
    • 2014
  • Analysis of faults in induction motors has become a major field of research due to importance of loss and damage reduction and maximum online performance of motors. There are several methods to analyze the faults in an induction motor from conventional Fourier transform to modern decision-making neural networks. Considering detectability of fault among all methods, a new fault detection solution has been proposed; it is called as frequency-domain Discrete Wavelet Transform (FD-DWT). In this method, the stator current is decomposed through series of low- and high-pass filters and consequently, the fault characteristics are more visible, because additional components have been reduced. The objective of this paper is early detection of input voltage unbalance in induction motor using wavelet transform in frequency domain. Experimental results show the effectiveness of the proposed method in early detection of faults.

  • PDF

Comparison of VUF using Resistor & Inductive Load (저항성 및 유도성 부하의 운전시 전압불평형율의 비교)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong;Lee, Jong-Han;Lee, Dong-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1062-1064
    • /
    • 2005
  • 3 phase 4-wire system has been widely used in the customer's application due to merit of 1 bank construction of loads such as 1-phase lighting, heat and 3-phase motor. But if the load distribution is not uniformed by the operation conditions, voltage unbalance is highly appeared by the difference of each phase current value. Especially, if the linear load such as resistance or inductive load has different power factor value, voltage unbalance factor is not the same due to the phase angle and magnitude of each phase voltage. In this paper, we composed the measurement device and analyzed by varying of load pattern.

  • PDF

An Islanding Detection Method for Distributed Generations Using the Voltage Unbalance (전압 불평형율을 이용한 분산전원의 고립운전 검출 기법)

  • Jang S. I.;Park J. K.;Kim K. H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.42-44
    • /
    • 2004
  • This paper introduced and proposed the voltage unbalance of DC terminal output as new monitoring parameter for power islanding detection. This paper also presented a simple and novel detection algorithm, which effectively combines the detection results of the conventional parameter, voltage magnitude, and a newly proposed parameter. We tested the proposed method using several distribution network conditions including not only islanding operation conditions, but also non-islanding conditions of normal network load variations. The test results showed that the proposed parameters and algorithm are capable of correctly detecting the islanding operation not affected by variation of DG loading and also have a good selectivity for islanding conditions and non-islanding conditions.

  • PDF

Operation Analysis of Novel UPQC(Unified Power Quality Conditioner) without Series Injection Transformers (직렬주입변압기가 없는 새로운 UPQC(Unified Power Quality Conditioner)의 성능분석)

  • Kim H.J.;Bae B.Y.;Jon Y.S.;Han B.M.;Kim H.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.251-255
    • /
    • 2003
  • This paper proposes a novel UPQC(unified power quality conditioner) based on H-bridge modules, isolated through single-phase multi-winding transformers. The dynamic performance of proposed system was analyzed by simulation with EMTDC/PSCAD, assuming that the UPQC is connected with the 22.9kV distribution line. The proposed system can be directly connected to the transmission line without series injection transformers. It has flexibility in expanding the operation voltage by increasing the number of H-bridge modules and can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance. The control strategy for the proposing UPQC was derived using the instantaneous power method. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems and can be utilized for the future distribution system.

  • PDF

A Grid Current-Controlling Shunt Active Power Filter

  • Tumbelaka, Hanny H.;Borle, Lawrence J.;Nayar, Chemmangot V.;Lee, Seong-Ryong
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.365-376
    • /
    • 2009
  • In this paper, the implementation of a three-phase shunt active power filter is presented. The filter is essentially three independent single-phase current-controlled voltage source inverters (CC-VSI) with a common DC bus. The CC- VSI is operated to directly control the AC grid current to be sinusoidal and in phase with the grid voltage without detecting the load currents. The APF consists of a current control loop, which shapes the grid currents to be sinusoidal and a voltage control loop, which regulates the active power balance of the system. The experimental results indicate that the active filter is able to handle predominantly the harmonics, as well as the unbalance and reactive power, so that the grid currents are sinusoidal, in phase with the grid voltages and symmetrical.

Adaline-Based Control of Capacitor Supported DVR for Distribution System

  • Singh, Bhim;Jayaprakash, P.;Kothari, D.P.
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.386-395
    • /
    • 2009
  • In this paper, a new control algorithm for the dynamic voltage restorer (DVR) is proposed to regulate the load terminal voltage during various power quality problems that include sag, swell, harmonics and unbalance in the voltage at the point of common coupling (PCC). The proposed control strategy is an Adaline (Adaptive linear element) Artificial Neural Network (ANN) and is used to control a capacitor supported DVR for power quality improvement. A capacitor supported DVR does not need any active power during steady state because the voltage injected is in quadrature with the feeder current. The control of the DVR is implemented through derived reference load terminal voltages. The proposed control strategy is validated through extensive simulation studies using the MATLAB software with its Simulink and SimPower System (SPS) toolboxes. The DVR is found suitable to support its dc bus voltage through the control under various disturbances.

A Study on the Unbalanced Current Distribution of HTS Power Cable (초전도 전력케이블의 전류 불평형에 관한 연구)

  • Kim, Jae-Ho;Park, Chung-Hwa
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.43-47
    • /
    • 2012
  • The unbalance currents flow the High Temperature Superconducting (HTS) power cable caused by asymmetrical fault, harmonic distortion and unbalanced load. That problem causes additional loss and leakage field in the HTS power cable, and deteriorates the electric power quality and stability. In addition, large amounts of unbalanced current can cause negative sequence and ground relays to operate. This paper presents an analysis unbalanced three-phase current distribution in HTS power cable caused by unbalanced load condition and grounding methods using PSCAD/EMTDC. The results obtained through the analysis would provide important data for the design of HTS power cables and valid information for their installation in power system.