• 제목/요약/키워드: Power to gas

검색결과 4,311건 처리시간 0.045초

친환경 하이브리드 동력 시스템 개발 및 농기계 응용 (Development of an Environmental Friendly Hybrid Power System and its Application to Agricultural Machines)

  • 김상철;홍영기;김국환
    • 제어로봇시스템학회논문지
    • /
    • 제21권5호
    • /
    • pp.447-452
    • /
    • 2015
  • A hybrid power system was developed for agricultural machines with a 20kW output capacity, and it was attached to a multi-purpose cultivator to improve the performance of the cultivator. The hybrid system combined heterogeneous sources: an internal-combustion engine and an electric power motor. In addition, a power splitter was developed to simplify the power transmission structure. The cultivator using a hybrid system was designed to have increased fuel efficiency and output power and reduced exhaust gas emissions, while maintaining the functions of existing cultivators. The fuel consumption for driving the cultivator in the hybrid engine vehicle (HEV) mode was 341g/kWh, which was 36% less than the consumption in the engine (ENG) mode for the same load. The maximum power take off output of the hybrid power system was 12.7kW, which was 38% more than the output of the internal-combustion engine. In the HEV mode, harmful exhaust gas emissions were reduced; i.e., CO emissions were reduced by 36~41% and NOx emissions were reduced by 27~51% compared to the corresponding emissions in the ENG mode. The hybrid power system improved the fuel efficiency and reduced exhaust gas emissions in agricultural machinery. The hybrid system's lower exhaust gas emissions have considerable advantages in closed work environments such as crop production facilities. Therefore, agricultural machinery with less exhaust gas emissions should be commercialized.

Coal Bed Methane을 사용한 다양한 응용 기술에 대한 고찰 (A Study on Various Application Technologies Using Coal Bed Methane)

  • 조원준;이제설;유혜진;이현찬;주우성;임옥택
    • 한국수소및신에너지학회논문집
    • /
    • 제29권1호
    • /
    • pp.130-137
    • /
    • 2018
  • Now discusses the potential use and applications of coal bed methane (CBM) in various industries. One of the options for gas monetization is gas to power (GTP), sometimes called gas to wire (GTW). Electric power can be an intermediate product, such as in the case of mineral refining in which electricity is used to refine bauxite into aluminum; or it can be an end product that is distributed into a large utility power grid. For stranded gas, away from the regional markets, the integration of the ammonia and urea plants makes commercial sense. These new applications, if established, could lead to a surge in demand for methanol plants.

건식 저 NOx 가스터빈의 연소동압 측정용 소프트웨어 시스템 개발 (Development of a Software System for Measurements of Combustion Dynamics of a Dry Low NOx Gas Turbine)

  • 장욱;서석빈;정재화;안달홍;김종진;차동진
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.931-938
    • /
    • 2002
  • Combustion dynamics of a dry low NOx gas turbine have been measured by utilizing a dynamic pressure measurement system. The software part of the measurement system, implemented with a commercial general-purpose DASYLab version 5.6 code, basically acquires combustion dynamics signals, performs the FFT analysis, and displays the results. The gas turbine often experiences momentary combustion instability, especially when its combustion mode changes. It is found that the measurement system developed in the study may outperform the other commercial dynamic pressure measurement system. The developed system currently serves to monitor the combustion dynamics of the gas turbine.

Stack Performances of Proton Exchange Membrane Fuel Cell

  • Kho, Young-Tai;Cho, Won-Ihl;Park, Yong-Woo-
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1994년도 추계학술발표회 초록집
    • /
    • pp.14-16
    • /
    • 1994
  • The development of proton exchange membrane fuel cells(PEMFCs) with high energy efficiencies and high power densities is gaining momentum because their performance characteristics are attractive for terrestrial(power sources for electrical vehicles, stand-by power), space and underwater application[1]. Fuel cells are capable of running on non-petroleum fuels such as methanol, natural gas or hydrogen and also have major impact on improving air quality. They virtually eliminate particulates, NO$_{x}$, SO$_{x}$, and significant reduce hydrocarbons and carbon monoxide. Especially, fuel cell-battery hybrid power sources appear to be well suited to overcome both the so-called battery problem(low energy density) and the fuel cell problem(low power density)[2].[2].

  • PDF

Environmental Assessment of Smart Grid Station Project Centered on Pilot Project of Korea Electric Power Corporation Building

  • Park, Sun-Kyoung;Son, Sung-Yong;Kim, Dongwook;Kim, Buhm-Kyu
    • 한국기후변화학회지
    • /
    • 제7권3호
    • /
    • pp.217-229
    • /
    • 2016
  • Increased evidences reveal that the global climate change adversely affect on the environment. Smart grid system is one of the ways to reduce greenhouse gas emissions in the electricity generation sector. Since 2013, Korea Electric Power Corporation (KEPCO) has installed smart grid station in KEPCO office buildings. The goal of this paper is two folds. One is to quantify the reduction in greenhouse gas emissions through smart grid stations installed in KEPCO office buildings as a part of pilot project. Among components of smart grid stations, this research focused on the photovoltaic power system (PV) and energy storage system (ESS). The other is to estimate the reduction in greenhouse gas emissions when PV is applied on individual houses. Results show that greenhouse gas emissions reduce 5.8~11.3% of the emissions generated through the electricity usage after PV is applied in KEPCO office buildings. The greenhouse gas emissions reduction from ESS is not apparent. When PV of 200~500 W is installed in individual houses, annual greenhouse gas emission reduction in 2016 is expected to be approximately $2.2{\sim}5.4million\;tCO_2-eq$, equivalent to 6~15% of greenhouse gas emissions through the electricity usage in the house hold sector. The saving of annual electricity cost in the individual house through PV of 200 W and 500 W is expected to be 47~179 thous and KRW and 123~451 thousand KRW, respectively. Results analyzed in this study show the environmental effect of the smart grid station. In addition, the results can be further used as guidance in implementing similar projects.

4기통 디젤기관에 적용한 천연가스 예혼합 압축착화 기관의 연소특성 (Combustion Characteristics of Pre-mixed Charge Compression Ignition Engines with Natural Gas Applied to 4-Cylinders Diesel Engine)

  • 정석호
    • 동력기계공학회지
    • /
    • 제13권2호
    • /
    • pp.5-10
    • /
    • 2009
  • In recently, studies concerned to the diesel engine uses a natural gas as a fuel oil whose infra has been built already was approached to PCCI or HCCI with keeping a high thermal efficiency and reducing NOx and PM have been researching actively in normally single cylinder. An ignition source is required to bum the natural gas by a spark plug in gasoline engines, due to a higher auto-ignition temperature of natural gas. Then gas oil and DME were introduced as the ignition source. In this study as basic data for practical use of natural gas PCCI and HCCI engines, combustion characteristics and emission characteristics on 4-cylinders natural gas PCCI and HCCI engines with gas oil and DME as ignition sources were analyzed and the engine load range that is main object for practical use of PCCI and HCCI engines was made clearly by empirical experiment.

  • PDF

가스터빈 동기기 통합형 기동 및 여자시스템 개발 (Development of Integrated Start-up and Excitation System for Gas Turbine Synchronous Generator)

  • 류호선;차한주
    • 전기학회논문지P
    • /
    • 제63권3호
    • /
    • pp.183-188
    • /
    • 2014
  • Power conversion systems used in large gas turbine power plant can be divided into two main part. Because of the initial start-up characteristic of the gas turbine combustor, the gas turbine must be accelerated by starting device(LCI : Load Commutated Inverter) up to 10%~20% of rated speed to ignite it. In addition, the ECS(Excitation Control system) is used to control the rotor field current and reactive power in grid-connected synchronous generator. These two large power conversion systems are located in the same space(container) because of coordination control. Recently, many manufactures develop high speed controller based on function block available in the LCI and ECS with the newest power semiconductor. We also developed high speed controller based on function block to be using these two system and it meets the international standard IEC61131 as using real-time OS(VxWorks) and ISaGRAF. In order to install easily these systems at power plant, main controller, special module and IO module are used with high speed communication line other than electric wire line. Before initial product is installed on the site, prototype is produced and tests are conducted for it. The performance results of Integrated controller and application program(SFC, ECS) were described in this paper. The test results will be considered as the important resources for the application in future.

가스배관과 철탑접지의 이격거리 관련 기준 (Standards of Distance between Gas Pipeline and Tower Ground)

  • 이현구;하태현;하윤철;배정효;김대경
    • 한국가스학회지
    • /
    • 제11권1호
    • /
    • pp.18-22
    • /
    • 2007
  • 전력선에 지락고장이 발생할 경우 대지로 유입된 고장전류에 의하여 인접한 배관에 아크 용융이 발생하면 가스폭발이나 기름유출과 같은 대형사고를 발생시킬 수 있으며, 배관의 유지 및 보수를 담당하는 작업자의 안전에도 위험을 초래할 수 있다. 본 논문에서는 대지를 통한 철탑과 배관 사이의 아크 발생에 대하여 알아보고, 국내외에서 사용되고 있는 철탑 인근에 매설된 배관의 이격거리 기준을 조사하였다.

  • PDF

전력기기 이상 진단을 위한 가스 센싱 기술 검토 (Gas Sensing Technologies for Power System Diagnosis)

  • 이재덕;류회석;최상봉;남기영;정성환;김대경;최돈수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.622-624
    • /
    • 2004
  • To reduce the effect of fault on power systems, like GIS and transformers, power system authorities are using various technologies to monitor and diagnose there facilities. Developing On-Line monitoring systems by using IT technology is main issue of nowadays for power system authorities. Among various monitoring and diagnosis technologies, gas sensing technologies can be most useful candidate because large power systems are using gas and oils for there insulation and analyzing density of gases that are included in the gas and oils for insulation purpose tell us what kind of reaction were arisen. In this paper, we describe on the gas sensing technology that are used for power systems monitoring and diagnosis.

  • PDF

전력수급기본계획의 불확실성과 CO2 배출 목표를 고려한 발전용 천연가스 장기전망과 대책 (Scenario Analysis of Natural Gas Demand for Electricity Generation in Korea)

  • 박종배;노재형
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1503-1510
    • /
    • 2014
  • This study organizes scenarios on the power supply plans and electricity load forecasts considering their uncertainties and estimates natural gas quantity for electricity generation, total electricity supply cost and air pollutant emission of each scenario. Also the analysis is performed to check the properness of government's natural gas demand forecast and the possibility of achieving the government's CO2 emission target with the current plan and other scenarios. In result, no scenario satisfies the government's CO2 emission target and the natural gas demand could be doubled to the government's forecast. As under-forecast of natural gas demand has caused the increased natural gas procurement cost, it is required to consider uncertainties of power plant construction plan and electricity demand forecast in forecasting the natural gas demand. In addition, it is found that CO2 emission target could be achieved by enlarging natural gas use and demand-side management without big increase of total costs.