• Title/Summary/Keyword: Power system dynamic stability

Search Result 353, Processing Time 0.026 seconds

Fast-Transient Repetitive Control Strategy for a Three-phase LCL Filter-based Shunt Active Power Filter

  • Zeng, Zheng;Yang, Jia-Qiang;Chen, Shi-Lan;Huang, Jin
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.392-401
    • /
    • 2014
  • A fast-transient repetitive control strategy for a three-phase shunt active power filter is presented in this study to improve dynamic performance without sacrificing steady-state accuracy. The proposed approach requires one-sixth of the fundamental period required by conventional repetitive control methods as the repetitive control time delay in the synchronous reference frames. Therefore, the proposed method allows the system to achieve a fast dynamic response, and the program occupies minimal storage space. A proportional-integral regulator is also added to the current control loop to eliminate arbitrary-order harmonics and ensure system stability under severe harmonic distortion conditions. The design process of the corrector in the fast-transient repetitive controller is also presented in detail. The LCL filter resonance problem is avoided by the appropriately designed corrector, which increases the margin of system stability and maintains the original compensation current tracking accuracy. Finally, experimental results are presented to verify the feasibility of the proposed strategy.

Probabilistic Security Analysis in Composite Power System Reliability (복합전력계통 신뢰도평가에 있어서 확률론적 안전도연구)

  • Kim, H.;Cha, J.;Kim, J.O.;Kwon, S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.46-48
    • /
    • 2005
  • This paper discusses a probabilistic method for power system security assessment. The security analysis relates to the ability of the electric power systems to survive sudden disturbances such as electric short circuits or unanticipated loss of system elements. It consists of both steady state and dynamic security analyses, which are not two separate issues but should be considered together. In steady state security analysis including voltage security analysis, the analysis checks that the system is operated within security limits by OPF (optimal power flow) after the transition to a new operating point. Until now, many utilities have difficulty in including dynamic aspects due to computational capabilities. On the other hand. dynamic security analysis is required to ensure that the transition may lead to an acceptable operating condition. Transient stability, which is the ability of power systems to maintain synchronism when subjected to a large disturbance. is a principal component in dynamic security analysis. Usually any loss of synchronism may cause additional outages and make the present steady state analysis of the post-contingency condition inadequate for unstable cases. This is the reason for the need of dynamic studies in power systems. Probabilistic criterion can be used to recognize the probabilistic nature of system components while considering system security. In this approach. we do not have to assign any predetermined margin of safety. A comprehensive conceptual framework for probabilistic static and dynamic assessment is presented in this paper. The simulation results of the Western System Coordinating Council (WSCC) system compare an analytical method with Monte-Carlo simulation (MCS).

  • PDF

A Study for Dynamic Equivalent Models in Large Power System (대규모 전력계통의 동적등가 축약모형 연구)

  • Chang, Byung-Hoon;Choo, Jin-Boo;Kwon, Sea-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1305-1307
    • /
    • 1999
  • dynamic analysis of power systems is required the information for building a transfer function of has the heavy calculation of high order matrices. Since generally the order of the state matrix is over the limit of commercial analysis programs such as MASS(Multi-Area Small Signal Stability) Program, it is necessary to develop dynamic equivalent systems with preserving essential properties of the original system. In this work, a procedurd to find an optimal location of FACTS controllers is presented. The procedure was applied to KEPCO system in the year of 2000. The results on a test system demonstrate the accuracy of dynamic equivalencing and verify the effect of FACTS controllers.

  • PDF

Dynamic stability and structural improvement of vibrating electrically curved composite screen subjected to spherical impactor: Finite element and analytical methods

  • Xiao, Caiyuan;Zhang, Guiju
    • Steel and Composite Structures
    • /
    • v.43 no.5
    • /
    • pp.533-552
    • /
    • 2022
  • The current article deals with the dynamic stability, and structural improvement of vibrating electrically curved screen on the viscoelastic substrate. By considering optimum value for radius curvature of the electrically curved screen, the structure improvement of the system occurs. For modeling the electrically system, the Maxwell's' equation is developed. Hertz contact model in employed to obtain contact forces between impactor and structure. Moreover, variational methods and nonlinear von Kármán model are used to derive boundary conditions (BCs) and nonlinear governing equations of the vibrating electrically curved screen. Galerkin and Multiple scales solution approach are coupled to solve the nonlinear set of governing equations of the vibrating electrically curved screen. Along with the analytical solution, 3D finite element simulation via ABAQUS package is provided with the aid of a FE package for simulating the current system's response. The results are categorized in 3 different sections. First, effects of geometrical and material parameters on the vibrational performance and stability of the curves panel. Second, physical properties of the impactor are taken in to account and their effect on the absorbed energy and velocity profile of the impactor are presented. Finally, effect of the radius and initial velocity on the mode shapes of the current structure is demonstrated.

Transient Stability Enhancement of Power System Connected to a Wind Farm Using STATCOM (STATCOM을 이용한 풍력단지가 연계된 전력계통의 과도안정도 향상)

  • Seo, Gyu-Seok;Park, Ji-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4115-4120
    • /
    • 2015
  • To ensure the transient stability of power system connected to a wind farm, wind power plant must be able to supply reactive power at the point of the common coupling(PCC). The reactive power capability of each individual wind turbine may not sufficient to maintain stability. Also, there are large reactive power losses in connection cables between wind farm and PCC. The static synchronous compensator(STATCOM) is considered for transient stability enhancement, because it provides many advantages such as the fast response time and superior reactive power support capability. In this paper, the effectiveness of a STATCOM in enhancing transient stability of power system connected to a wind farm is presented. The results of dynamic simulations show that STATCOM installed at the PCC can enhance transient stability.

New Technology of Static Excitation System Considering Dynamic Stability (과도 안정도를 고려한 정지형 여자기의 새로운 설계기술)

  • Rhew, Hong-Woo;Kim, Chan-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.47-55
    • /
    • 1996
  • A new generator excitation system using a boost-buck chopper as a kind of static exciters is proposed to overcome the lack of field forcing capability of the bus fed exciter under the input line fault condition. It increases or maintains the generator field current by boosting the field voltage in the case of the input AC line voltage drop during and immediately after a fault. The validity of the proposed excitation system is verified with the computer simulation. The generator stability according to the each difference exciter is tested using a commercial software package-CYME. The simulation results of the stability analysis on the generator with the proposed exciter is better than that of the bus fed exciter. This boost-buck chopper exciter can be simply implemented and controlled by the modern power electronics technology.

  • PDF

Reduced Order Identification and Stability Analysis of DC-DC Converters

  • Ali, Husan;Zheng, Xiancheng;Wu, Xiaohua;Zaman, Haider;Khan, Shahbaz
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.453-463
    • /
    • 2017
  • This paper discusses the measurement of frequency response functions for various dc-dc converters. The frequency domain identification procedure is applied to the measured frequency responses. The identified transfer functions are primarily used in developing behavioral models for dc-dc converters. Distributed power systems are based upon such converters in cascade, parallel and several other configurations. The system level analysis of a complete system becomes complex when the identified transfer functions are of high order. Therefore, a certain technique needs to be applied for order reduction of the identified transfer functions. During the process of order reduction, it has to be ensured that the system retains the dynamics of the full order system. The technique used here is based on the Hankel singular values of a system. A systematic procedure is given to retain the maximum energy states for the reduced order model. A dynamic analysis is performed for behavioral models based on full and reduced order frequency responses. The close agreement of results validates the effectiveness of the model order reduction. Stability is the key design objective for any system designer. Therefore, the measured frequency responses at the interface of the source and load are also used to predict stability of the system.

Transient Stability assessment in the real power system using Energy Function. (에너지함수를 이용한 실계통에의 과도 안정도 평가 적용)

  • Kwon, Tae-Won;Lee, Kyung-Jae;Lee, Byung-Ha;Ham, Wan-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.153-156
    • /
    • 1992
  • Transient stability analysis of Korea Electric power Corporation(KEPCO) system is conducted by time simulation method, and the method is robust and reliable. But, time simulation consumes enormous computing resources and engineering time, and it does not provide a measure of the degree of stability of the system. Therefore, this method does not apply to every changed condition appropriately and quickly in planning and operating. And Transient Energy Function (TEF) method whis can assess quickly and quantatively the degree of stability of the system and which judges the stability and the instability to analyse transient dynamic charater of the system by mutual changing kinetic energy and potential energy, is developed. TEF method analyses the first Swing transient stability of the system by using the thought that if after disturbance happening, the increase of all the rotator kinetic energy changes into the potential energy after diturbance clearing, the system is stable, otherwise the system is unstable. This paper represents the availabiIity of the TEF method by comparing with time simulation method on the two cases.

  • PDF

Dynamic Characteristics of Proportional Flow Control Valve with Large Capacity (대용량 비례 유량제어밸브 동특성 분석)

  • Jung, G.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.1
    • /
    • pp.20-27
    • /
    • 2010
  • Electromagnetic control valves have been used for almost 20 years. As the solenoid modulating technology advances, its applications are extending to various industrial fields such as nuclear and fossil fuel power plants, chemical plants and refineries. Proportional solenoid valve for large flow control is designed with two-stage configuration to meet the required actuating force on the main disc and its position is stabilized by the self-controlled system. In this research, main disc dynamics is analyzed with linearized system model which is derived from the mathematical equations describing its nonlinear behavior. Major design parameters of the valve control system that affect the response and stability are also studied with root locus method. The linear dynamic analysis results are verified with simulations in time-domain.

  • PDF

The Analysis and Evaluation of the Disturbances and Controller Effects to Power System Dynamic Voltage Stability (동적전압붕괴에 대한 외란의 영향평가 및 제어기기 적용효과 분석)

  • Lee, Geun-Joon;Choo, Jin-Bu;Kim, Kern-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.886-890
    • /
    • 1997
  • This paper presents shows various process of dynamic voltage collapses which were initiated by power system disturbances, and the impacts of dynamic voltage controllers. According to the analysis results, the composition of induction motors with short time constant strongly affect the voltage collapse. To escape the voltage collapse, adding fast acting reactive compensation device, such as SVC, at high reactive loss sensitivity(${\partia}Qloss/{\partia}PL$) point could be one of a good countermeasure.

  • PDF