• 제목/요약/키워드: Power system analysis

검색결과 9,420건 처리시간 0.036초

전력계통 안정화장치(PSS)의 성능향상을 위한 입력신호 영향 (The Effect of input signals for improving Power System Stabilizer(PSS) efficiency)

  • 허진;김동준;김태균;신정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.144-146
    • /
    • 1999
  • This paper provides an analysis of the effect of input signals, such as acceleration power and generator shaft speed for improving Power System Stabilizer(PSS) efficiency. We consider a single machine and infinite bus system which is modeled by PSCAD/EMTDC. We choose an optimum stabilizer gain with respect to eigenvalue analysis and transient stability analysis to each input signal.

  • PDF

Protection Assessment using Reduced Power System Fault Data

  • Littler, T.B.
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권2호
    • /
    • pp.172-177
    • /
    • 2007
  • Wavelet transforms provide basis functions for time-frequency analysis and have properties that are particularly useful for the compression of analogue point on wave transient and disturbance power system signals. This paper evaluates the compression properties of the discrete wavelet transform using actual power system data. The results presented in the paper indicate that reduction ratios up to 10:1 with acceptable distortion are achievable. The paper discusses the application of the reduction method for expedient fault analysis and protection assessment.

제주계통 풍력발전단지의 무효전력 특성 분석 (Analysis of Reactive Power Characteristic for Wind Farms in Jeju System)

  • 최영도;박영신;전동훈;윤기갑;박상호
    • 신재생에너지
    • /
    • 제6권2호
    • /
    • pp.19-26
    • /
    • 2010
  • Experiences in wind farm operation are very limited in Korea, and the foundation for setting standards in power system connection is weak. Therefore, connection and operation standards for wind farms in other countries must be reviewed and power system operation criteria need to be established in order to set up connection standards and optimal operation plans according to the Jeju power system. In this study, reactive power control characteristics of a wind farm were analyzed using a wind farm model of the Jeju power system to propose power system connection operation standards for wind generation within the Jeju power system. Also, change in characteristics of the power system for the application of each reactive power control standard was confirmed, and the results were verified through trial tests arm was analyzed.

하이브리드 동력시스템을 적용한 트랙터의 동적 거동 및 내구해석 (Behavior and Durability Analysis of Tractor applying a hybrid power system)

  • 김병삼;임광규
    • 자동차안전학회지
    • /
    • 제6권2호
    • /
    • pp.61-66
    • /
    • 2014
  • This paper described on the motion of hybrid tractor trajectory for powertrain system. The dynamics behavior used to the tractor according to the characteristics of the road surface using $Daful^@$ analysis. The tractor industry is facing to a big problem about rising gas price and exhaust gas environment. Because it was possible overcoming the past drawback, hybrid vehicle had been decided as the best technical way since it has started operating the internal combustion engine with the electric power as the motive power. The vehicle structures have designed the model of a major power transmission factor. The simulation realized in this paper that motion of tractor being turned by torque and force of each joints. Driving characteristics, especially in recent years, IVHS (Intelligent Vehicle Tractor / System) technology, while receiving a lot of attention because of the tractor and the need to pursue high function is emerging as a more and more.

발전용 증기밸브 누설량 평가에 관한 연구 (Study on Evaluation of the Leak Rate for Steam Valve in Power Plant)

  • 이상국;박종혁;유근배
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.45-50
    • /
    • 2007
  • Acoustic emission technology is applied to diagnosis the internal leak and operating conditions of the major valves at nuclear power plants. The purpose of this study is to verify availability of the acoustic emission as in-situ diagnosis method. In this study, acoustic emission tests are performed when the pressurized high temperature steam flowed through gate valve(1st stage reheater valve) and glove valve(main steam dump valve) on the normal size of 4 and 8". The valve internal leak diagnosis system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, signal level analysis and RMS(root mean square) analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

온라인 웹기반 원전 터빈 사이클 열성능 분석 시스템 (Web-Based On-Line Thermal Performance Analysis System for Turbine Cycle of Nuclear Power Plant)

  • 최기상;최광희;지문학;홍승열;김성근
    • 대한기계학회논문집B
    • /
    • 제29권3호
    • /
    • pp.409-416
    • /
    • 2005
  • We need to develop a on-line thermal performance analysis system for nuclear power plant to determine performance status and heat rate of turbine cycle. We have developed PERUPS(PERformance Upgrade System) to aid the effective performance analysis of turbine cycle. Procedures of performance calculation are improved using several adaptations from standard calculation algorithms based on PTC(Performance Test Code). Robustness in the on-line performance analysis is increased by verification & validation scheme for measured input data. The system also provides useful web interfaces for performance analysis such as graphic heat balance of turbine cycle and components, turbine expansion lines, automatic generation of analysis report. The system was successfully applied for YongGwang nuclear plant unit #3,4.

원전사고 평가를 위한 원전 사건유형분석 시스템(ETAS) 개발 (Development of the Event Type Analysis System (ETAS) for the Accident Evaluation in Nuclear Power Plants)

  • 최영환;김영미
    • 한국압력기기공학회 논문집
    • /
    • 제5권2호
    • /
    • pp.35-39
    • /
    • 2009
  • In this study, Event Type Analysis System (ETAS) is developed for the accident evaluation in nuclear power plant. The ETAS system can be used in supporting regulator and/or operator under event situation in nuclear power plants. The ETAS system can categorize the all transient events to 3 categories such as Down-2000, Down-2173, and Slow Fluctuation. We develop the program structure for ETAS system and web-based ETAS system. The ETAS system will be used as sub module of Knowledge-Based Event Evaluation Network (K-EvENT) which is developing for the against the accident in nuclear power plants.

  • PDF

발전기 탈락에 따른 주파수의 전파속도 해석에 관한 연구 (A Study on Analysis of Propagation Speed of Power Frequency by Generation Drop)

  • 김학만;박철원
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.295-300
    • /
    • 2014
  • The frequency is an important operating parameter of a power system. There is an increasing importance of constant monitoring of frequency to achieve stable power supply by WAMS(wide area monitoring system) and FNET(Frequency Monitoring Network). This paper is part of development of a network-based frequency monitoring and failure prediction system for wide-area intelligent protection relaying. In this paper, analysis of propagation speed of power frequency by generation drop using the PSS/E was carried out. For dynamic analysis, the 11 metropolitan areas offices of KEPCO divided into five groups of Seoul, Gangwon, Chungcheong, Honam, and Yeongnam group, study was performed.

소형 열병합 발전소의 계통연계시 방향성 과전류 및 지락과전류 계전기의 적용 검증 연구 (A Study of Verification on Application of Directional OCR and OCGR for Power System with Small Scale Cogeneration)

  • 이희태;조만영;김재철
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.944-950
    • /
    • 2008
  • When small cogenerators are operated in connected with power system, there are many positive aspects such as the reduction of power plant construction, making a improvement of power security etc. At the same time, there are some negative effects or difficulties such as we should make sure of protective coordination, especially, Actually these are not fault, but it is likely to consider the current as the fault. This is one of major causes of malfunctions for protective relays in power distribution system which is including interconnection point. Thus, in this paper, We showed that the directional protection is necessary to the dispersed generation system which is including connection point. We also executed contingency analysis to find out the magnitude of fault current and direction which are classified by fault points, length of line and kinds of faults using ETAP power system analysis program.

동북아 전력계통 연계로 인한 환경성 분석 및 국내 전원구성에의 영향 평가 (Environmental Analysis and Evaluation on Fuel Mix by Electric Power System Interconnection in Northeast Asia)

  • 정구형;김홍근;김발호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.769-771
    • /
    • 2005
  • Interconnection of electric power systems, as an alternative for energy cooperation under regional economic bloc, has been under extensive debate before progressing the restructure in electric power industry and rapidly expanded in many regions after 1990s. Especially, since northeast asia has strong supplementation in resource, load shape, fuel mix etc., electric power system interconnection in this region may bring considerable economic benefits. In this paper, we evaluate economic benefits from CO2 emission abatement and effectiveness on the fuel mix in Korea by the interconnection in northeast asia. For this analysis, we evaluate effects of CO2 emission abatement under various system interconnection scenarios and compare the results of fuel mix in Korean electric power system with and without transacted electricity via interstate electric power system in northeast asia.

  • PDF