• Title/Summary/Keyword: Power stability

Search Result 3,560, Processing Time 0.032 seconds

The Study of Compensation Strategy for FACTS Application in Power System (전력계통의 FACTS적용을 위한 직병렬 보상방안 연구)

  • Lee, Geun-Joon;Chang, Byung-Hoon;Kim, Yeng-Han
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.112-116
    • /
    • 1996
  • This paper presents the study results of FACTS application plan for transmission capability Enhancement. Power transfer across the KEPCO system resulting from a concentration of load in the Kyung-In area are subject to thermal, voltage and stability constrains. In the analysis study of the KEPCO system in 2000 and 2006 year. voltage stability analysis. modal analysis and dynamic stability were simulated by the power system analysis tools(VSTAB, PSS/E).

  • PDF

Response Characteristics Effectiveness of Power Converter According to Using of Error Compensator for PV Power System (태양광 전력설비를 위한 오차 보상기 사용의 전력변환기기에 대한 응답특성의 효과 검증)

  • Kim, Dong-Eun;Lee, Hyun-Jae;Shon, Jin-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.10
    • /
    • pp.1388-1394
    • /
    • 2018
  • In this paper, the improvement of the control response by using the error compensator to improve the stability of the control in the power conversion system is verified. Typically a closed loop control method is used to improve the control response characteristics in a traditional power conversion system and this is accomplished by generating a PWM waveform. In this paper, the newly constructed Type3 compensator to overcome the existing such as PI controller or Type2 compensator has been developed to improve the control stability of these closed loop control systems and the effectiveness of the use of error compensation devices was verified by presenting technique to improve stability and select its parameters by expanding the range of phase gains. Stability improvements are shown by the extension of the phase gain range and parameter selection techniques and the effects of using the error compensation device are verified accordingly.

A Modeling and Optimal Site of SMES for Power System Stabilization (계통안정화를 위한 SMES의 모델링과 적정위치 선정)

  • Kim, Jeong-Hun;Im, Jae-Yun;Lee, Jong-Pil
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.494-501
    • /
    • 1999
  • In this research, ANN modeling method of SMES unit is developed for stability analysis, and the optimal site is selected to maximize stabilization effect of SMES unit. The ANN is trained by learning data which is obtained through the application of complex test function into the traditional mathematical mode. In order to verify the validity of proposed modeling method, fault data of sample power system is applied to both the traditional and the ANN models. When the response of traditional and proposed models are compared, the average error for the active and reactive power are 2.51[%], and 0.24[%], respectively. From the comparison, the relevance of proposed method is validated. For the transient stability analysis, an application method of the proposed model is presented, and the transient stability performance index, which describes system stabilization effect of SMES at disturbance, is also suggested, and optimal site selection method of SMES is presented. In the viewpoint of the voltage stability, system stabilization criterion of local bus is presented from P­V curve, and then optimal site which can maximize the voltage stabilization of the whole power system, is decided from the proposed voltage stability performance index.

  • PDF

Impact of Dynamic Load Model on Short-Term Voltage Stability of Korea Power System and Estimation of Dynamic Load Model Parameters (국내 계통의 단기 전압 안정도에 대한 부하 모델의 영향성 검토 및 부하 모델 파라미터 선정)

  • Moon, Jaemin;Kim, Jae-Kyeong;Hur, Kyeon;Nam, Suchul;Kim, YongHak
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.1
    • /
    • pp.17-24
    • /
    • 2019
  • In this paper, we analyzed the effect of power system load model on the short-term voltage stability analysis results. First, we introduced common load models. We also confirmed that some load models can not represent actual system phenomena even if the model parameters are optimized. Also, we studied about the influences of load parameters and regional characteristics of load model on the sort-term voltage stability of KEPCO power system considering the contingency. The results showed that the importance of selecting a load model was confirmed again. And we recognized about it can be understood that it should reflect the load characteristics of the area near the assumed contingency more accurately.

Power System Stability Analysis Considering Motor Loads (모터부하를 고려한 ON-LINE 안정도 해석)

  • Park, Ji-Ho;Baek, Young-Sik;Lee, Hee-Choon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.316-318
    • /
    • 2000
  • In this paper. we have simulated the transient stability of power system with motor loads. In study of power system stability, modelling of motors is required for the system with large concentrations of motors. Therefore the dynamics attributable to motors are usually the most significant aspects of dynamics characteristics of system loads. A synchronous motor is modelled as a dynamic load. We investigate the effect of synchronous motors of Kwang Yang network with three phase fault.

  • PDF

A Study on the Analysis and Control of Voltage Stability (전압안정성 분석 및 제어에 관한 연구)

  • 장수형;김규호;유석구
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.869-876
    • /
    • 1994
  • This paper presents an efficient method to calculate voltage collapse point and to avoid voltage instability. To evaluate voltage stability in power systems, it is necessary to get critical loading points. For this purpose, this paper uses linear programming to calculate efficiently voltage collapse point. Also, if index value becomes larger than given threshold value, voltage stability is improved by compensation of reactive power at selected bus. This algorithm is verified by simulation on the IEEE 14-bus sample system.

  • PDF

Frequency Stability Enhancement of Power System using BESS (BESS를 활용한 전력계통 주파수 안정도 향상)

  • Yoo, Seong-Soo;Kwak, Eun-Sup;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.595-606
    • /
    • 2022
  • Korea has the characteristics of traditional power system such as large-scale power generation and large-scale power transmission systems, including 20 GW large-scale power generation complexes in several regions with unit generator capacity exceeding 1.4 GW, 2-3 ultra-high-voltage transmission lines that transport power from large-scale power generation complexes, and 6 ultra-high-voltage transmission lines that transport power from non-metropolitan areas to the metropolitan area. Due to the characteristics of the power system, the penetration level for renewable energy is low, but due to frequency stability issue, some generators are reducing the output of generators. In the future, the issue of maintaining the stability of the power system is expected to emerge as the most important issue in accordance with the policy of expanding renewable energy. When non-inertial inverter-based renewable energy, such as solar and wind power, surges rapidly, the means to improve the power system stability in an independent system is to install a natural inertial resource synchronous condenser (SC) and a virtual inertial resource BESS in the system. In this study, we analyzed the effect of renewable energy on power system stability and the BESS effect to maintain the minimum frequency through a power system simulation. It was confirmed that the BESS effect according to the power generation constraint capacity reached a maximum of 122.81 %.

Universal SSR Small Signal Stability Analysis Program of Power Systems and its Applications to IEEE Benchmark Systems

  • Kim, Dong-Joon;Nam, Hae-Kon;Moon, Young-Hwan
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.3
    • /
    • pp.139-147
    • /
    • 2003
  • The paper presents a novel approach of constructing the state matrix of the multi-machine power system for SSR (subsynchronous resonance) analysis using the linearized equations of individual devices including electrical transmission network dynamics. The machine models in the local d-q reference frame are integrated with the network models in the common R-I reference frame by simply transforming their output equations into the R-I frame where the transformed output is used as the input to the network dynamics or vice versa. The salient feature of the formulation is that it allows for modular construction of various component models without rearranging the overall state space formulation. This universal SSR small signal stability program provides a flexible tool for systematic analyses of SSR small-signal stability impacts of both conventional devices such as generation systems and novel devices such as power electronic apparatus and their controllers. The paper also presents its application results to IEEE benchmark models.

Step-One in Pre-regulator Boost Power-Factor-Correction Converter Design

  • Orabi, Mohamed;Ninomiya, Tamotsu
    • Journal of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.18-27
    • /
    • 2004
  • The output storage capacitor of the PFC converters is commonly designed for the selected hold-up time or the allowed output ripple voltage percentage. Nevertheless, this output capacitor is a main contribution factor to the PFC system stability. Moreover, seeking for a minimum output storage capacitor that assures the PFC desired operation under all condition, and providing the advantage of a small size and low cost is the main interesting target for engineering. Therefore, in this issue the design steps of the PFC converter have been discussed depending on three choices, output ripple, hold-up time, and stability. It is cleared that any design must take the minimum required storage capacitor for stability prospective as step-l in deign, then apply for any other specification like hold-up time or ripple percentage.

Stability Analysis of Jeiu Power System added with HVDC (HVDC 추가도입에 대한 제주도 계통의 정태 안정도 분석)

  • Shin, Seong-Su;Kim, Do-Hyung;Kim, Jae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.491-493
    • /
    • 2008
  • This paper presents results of comparing CSC HVDC with VSC HVDC on the stability in case of connecting Haenam to Jeju electrical power system, the steady-state stability in the case of Jeju electrical power system with CSC HYDC or VSC HVDC, is validated through PV curve, QV curve of Jeju electrical power system. And in the case of CSC HVDC, it is considered that synchronous condenser is connected or not. The results are compared each other. PSS/E simulation tool is used for the steady-state stability analysis.

  • PDF