• Title/Summary/Keyword: Power signals

Search Result 2,326, Processing Time 0.029 seconds

Diagnosis of Insulation Deterioration in Cast-Resin Power Transformer using Acoustic Emission Techniques (음향방출법에 의한 몰드형 전력변압기의 절연열화 진단)

  • 이상우;김인식;이동인;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.35-42
    • /
    • 2000
  • In this paper, AE(Acoustic Emission) signals detected from the growth of the electrical tree in an epoxy resin under ac high-voltage application were analysed to diagnose the insulation deterioration of cast-resin power transformer. Frequency spectra of AE signals generated from the magnetizing and the load currents in the actual operating cast-resin power transformer of 500[kVA] under distribution system of 22.9[kV] were also analysed to distinguish the AE signals due to void discharges from the magnetic circuit noises in the core of the transformer. As the experimental results, we could distinguish the AE signals whether those signals were caused due to the void discharges or due to the magnetic circuit noises by analyzing the frequency spectrum of AE signals. The frequency spectra of AE signals generated from the cast-resin power transformer in operation due to both the magnetizing and the load currents appeared in the range of 40-120[kHz], but the frequency band of AE signals emitted from the void discharges in an epoxy resin sample was about 50[kHz] to 230[kHz].

  • PDF

A Design of Predistortion Linearizer Controlling Modified Individual Order IM Signal (변형된 혼변조 신호 개별 차수 조정 전치왜곡 선형화기 설계)

  • 김영
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.10
    • /
    • pp.97-102
    • /
    • 2004
  • In this paper, a new predistorter controlling modified individual order jntermodulation distortion signals is proposed. The proposed predistorter generates and controls predistorted third and high order IM signals independently. Using predistorted signals, jntermodulation distortion signals of power amplifier are suppressed effectively. The predistortion linearizer has been implemented to operate in Korean PCS basestation transmitting band (1840~1870MHz). The test results show that IMD3 and IMD5 (C/I) of power amplifier are improved more than 40dB and 23dB for CW two tone signals, respectively. The predistorter improves the adjacent channel power ratio (ACPR) more than 10dB at 885KHz offset point for CDMA (IS-95) signals.

Simplified Control Scheme of Unified Power Quality Conditioner based on Three-phase Three-level (NPC) inverter to Mitigate Current Source Harmonics and Compensate All Voltage Disturbances

  • Salim, Chennai;Toufik, Benchouia Mohamed
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.544-558
    • /
    • 2013
  • This paper proposes a simplified and efficient control scheme for Unified Power Quality Conditioner (UPQC) based on three-level (NPC) inverter capable to mitigate source current harmonics and compensate all voltage disturbances perturbations such us, voltage sags, swells, unbalances and harmonics. The UPQC is designed by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The dc voltage is maintained constant using proportional integral voltage controller. The shunt and series AF are designed using a three-phase three-level (NPC) inverter. The synchronous reference frame (SRF) theory is used to get the reference signals for shunt and the power reactive theory (PQ) for a series APFs. The reference signals for the shunt and series APF are derived from the control algorithm and sensed signals are injected in tow controllers to generate switching signals for series and shunt APFs. The performance of proposed UPQC system is evaluated in terms of power factor correction and mitigation of voltage, current harmonics and all voltage disturbances compensation in three-phase, three-wire power system using MATLAB-Simulink software and SimPowerSystem Toolbox. The simulation results demonstrate that the proposed UPQC system can improve the power quality at the common connection point of the non-linear load.

Fault Discrimination of Power Transformers using Vibration Signal Analysis (진동 신호 분석을 이용한 전력용 변압기의 고장 판별)

  • Yoon, Yong-Han;You, Chi-Hyoung;Kim, Jae-Chul;Chung, Chan-Soo;Lee, Jung-Jin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In power transformers, vibration signals can occur at winding and core due to the change of current, voltage, and temperature and the deformation of winding and core. The deformation of winding and core occurs electromagnetic force induced by fault current in power systems. There firem the changes of vibration signals can be very different in normal or fault states of power transformers. We edtect and analyze the changes of vibration signals and use them as a tool for fault diagnosis of power transformers. This paper presents fault discriminating polliblility using the changes of fundamental waves and higher harmonics in power transformers. We showed the fault discriminating functions that are made at each case ; normal state and fault state. These functions are tested by the detected vibration signals, and we showed that the proposed method can discriminate the state of power transformers.

  • PDF

Analysis of Global Oscillation via Sync Search in Power Systems (전력계통에서 동조탐색과 광역진동해석)

  • Shim, Kwan-Shik;Nam, Hae-Kon;Kim, Yong-Gu;Moon, Young-Hoan;Kim, Sang-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1255-1262
    • /
    • 2009
  • The present study explained the phenomenon that low frequency oscillation is synchronized with discrete data obtained from a wide area system, and a sync search method. When a disturbance occurs in an power system, various controllers operate in order to maintain synchronization. If the system's damping is poor, low frequency oscillations continue for a long time and the oscillations are synchronized with one another at specific frequency. The present study estimated dominant modes, magnitude and phase of signals by applying parameter estimation methods to discrete signals obtained from an power system, and performed sync search among wide area signals by comparing the estimated data. Sync search was performed by selecting those with the same frequency and damping constant from dominant oscillation modes included in a large number of signals, and comparing their magnitude and phase. In addition, we defined sync indexes in order to indicate the degree of sync between areas in a wide area system. Furthermore, we proposed a wide area sync search method by normalizing mode magnitude in discrete data obtained from critical generator of the wide area. By applying the sync search method and sync indexes proposed in this study to two area systems, we demonstrated that sync scanning can be performed for discrete signals obtained from power systems.

UHF signals produced by motion of aluminium particles in GIS (GIS 내 알루미늄 파티클의 거동에 따른 UHF 신호발생 특성)

  • Yoon, Jin-Yeol;Park, Ki-Jun;Goo, Sun-Geun;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.525-527
    • /
    • 2000
  • Ultra high frequency (UHF) signals caused by the bouncing motion of aluminium particles in the 352 kV gas-insulated switchgear (GIS) test chamber were measured in order to investigate the signal pattern against the applied voltage phase and ultra sonic signals.

  • PDF

Characteristics of Elastic Waves Generated by Fatigue Crack Penetration and Growth in an Aluminum Plate

  • Ahn, Seok-Hwan;Nam, Ki-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.11
    • /
    • pp.1599-1607
    • /
    • 2003
  • The characteristics of elastic waves emanated from crack initiation in 6061 aluminum alloy subjected to fatigue loading are investigated through experiments. The objective of the study is to determine the differences in the properties of the signals generated from fatigue test and also to examine if the sources of the waves could be identified from the temporal and spectral characteristics of the acoustic emission (AE) waveforms. The signals are recorded using nonresonant, flat, broadband transducers attached to the surface of the alloy specimens. The time dependence and power spectra of the signals recorded during the tests were examined and classified according to their special features. Six distinct types of signals were observed. The waveforms and their power spectra were found to be dependent on the crack propagation stage and the type of fracture associated with the signals. The potential application of the approach in health monitoring of structural components using a network of surface mounted broadband sensors is discussed.

Propagation Characteristics of GIS PD Signals by Dual UHF Band Method (2)

  • Choi, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.136-139
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the propagation characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD detecting system in which PD signals are detected into the dual UHF band. The UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, propagation characteristics of GIS PD signals were measured in the mock-up GIS bus and it was found that the propagation characteristics of the high band showed a better result in accordance with the infernal configuration of the GIS bus than those of the full band.

  • PDF

Frequency Bin Alignment Using Covariance of Power Ratio of Separated Signals in Multi-channel FD-ICA (다채널 주파수영역 독립성분분석에서 분리된 신호 전력비의 공분산을 이용한 주파수 빈 정렬)

  • Quan, Xingri;Bae, Keunsung
    • Phonetics and Speech Sciences
    • /
    • v.6 no.3
    • /
    • pp.149-153
    • /
    • 2014
  • In frequency domain ICA, the frequency bin permutation problem falls off the quality of separated signals. In this paper, we propose a new algorithm to solve the frequency bin permutation problem using the covariance of power ratio of separated signals in multi-channel FD-ICA. It makes use of the continuity of the spectrum of speech signals to check if frequency bin permutation occurs in the separated signal using the power ratio of adjacent frequency bins. Experimental results have shown that the proposed method could fix the frequency bin permutation problem in the multi-channel FD-ICA.

Model Developments for Quantitative Estimates of the Benefits of the Signals on Nuclear Power Plant Availability and Economics (원자력발전소의 가용도와 경제성에 신호가 주는 이득의 정량적 산출을 위한 모델개발)

  • Seong, Poong-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.394-402
    • /
    • 1993
  • A novel framework for quantitative estimates of the benefits of signals on nuclear power plant availability and economics has been developed in this work. The models developed in this work quantify how the perfect signals affect the human operator's success in restoring the power plant to the desired state when it enters undesirable transients. Also, the models quantify the economic benefits of these perfect signals. The models have been applied to the condensate feedwater system of the nuclear power plant for demonstration.

  • PDF