• Title/Summary/Keyword: Power sharing control

Search Result 259, Processing Time 0.027 seconds

Characteristics Analysis According to Switching of Switched Reluctance Generator (스위치드 릴럭턴스 발전기의 스위칭에 따른 특성)

  • Oh, Jae-Seok;Oh, Ju-Hwan;Kwon, Byung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1356-1361
    • /
    • 2008
  • A switched reluctance generator(SRG) has simple magnetic structure, and needs simple power electronic driving circuit. But, a SRG are no windings or permanent magnets on the rotor, and there are concentrated windings placed around each salient pole on the stator. Because of the characteristics of time-sharing excitation, the control of SRG is very flexible. And there are several parameters for controlling SRG, such as switch turn-on angle, switch turn-off angle, and exciting voltage and controlling mode, all these will affect the generation greatly. A SRG has positive torque at increasing inductance region and negative torque at decreasing inductance region. In this paper, we studied characteristics about the switch turn-on and off angles according to switch method for constant output voltage of the fixed speed SRG. It is the acoustic noise and torque ripple characteristics. Characteristics for a switch angle and method are presented by experiment using a 50W SRG with 12/8 poles.

Sensor-less Direct Torque Control using Inductance Peak Detection for Switched Reluctance Motor (SRM의 상 인덕턴스를 이용한 센서리스 직접토크 제어)

  • Kim, Sang-Yub;Kim, Jae-Hoon;Kim, Rae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.209-210
    • /
    • 2015
  • 본 논문은 스위치드 릴럭턴스 전동기(Switched Reluctance Motor, 이하 SRM)의 상 인덕턴스를 추정하여 최고점과 최저점을 검출하는 방식으로 위치 센서를 이용하지 않는 직접토크 제어를 제안한다. 최고점으로부터 최저점의 위치 정보를 계산하여 이를 기준으로 회전 중인 회전자의 위치정보를 얻는다. 또한, 회전자의 위치정보를 필요로 하는 토크 계산 및 토크분배함수(Torque Sharing Function, 이하 TSF)는 상 인덕턴스 최저점 검출과 연관하여 계산하였다. 제안한 알고리즘은 시뮬레이션을 통하여 가능성을 입증하였다.

  • PDF

Power Control of a Hoist System Using Supercapacitor (수퍼캐패시터를 이용한 권상부하 시스템의 전력 제어)

  • Kim, Sang-Min;Sul, Seung-Ki;Yoo, Hyun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1486-1488
    • /
    • 2005
  • 본 논문에서는 수퍼캐패시터(Supercapacitor 이하 수퍼�L)를 이용하여 엔진 발전기를 전원으로 하는 권상부하 시스템의 부하전력 분배와 회생에너지의 저장 기법을 제안한다. 대표적인 권상부하 시스템인 크레인의 경우, 크게 두가지 운전모드로 동작한다. 첫번째 운전모드는 부하를 들어올리는 동작(Hoist-Up)으로서 가속 종료시점에서 최대전력을 소모한다. 두번째 운전모드는 부하를 내리는 동작(Hoist-Down)으로서 이때 희생되는 전력은 일반적으로 저항을 통하여 소모된다. 본 논문에서는 에너지 저장장치의 하나인 수퍼�L을 이용하여 Hoist-Down 운전에서 희생되는 에너지를 저장하고 Hoist-Up 운전에서 필요한 전력을 보조하도록 하였다. 수퍼�L의 충방전을 위하여 상용 3상 인버터와 동일한 구조를 가지는 DC-DC 컨버터를 제안하였다. 또한 발전기와 수퍼캐패시터의 Load Sharing을 최적화하기 위한 알고리즘을 제안하였다. 제안한 방법을 이용하면 디젤엔진 발전기의 크기를 대폭 줄일 수 있고 따라서 연비의 개선, 소음 및 공해의 감소를 기대할 수 있다. 제안한 방법의 타당성을 검증하기 위하여 시뮬레이션과 실험을 수행하였다.

  • PDF

Droop control considering harmonic reduction in the nonlinear load sharing of parallel operation inverter (병렬 운전 인버터의 비선형 부하 분담 시 고조파 저감을 고려한 드룹제어 연구)

  • Ko, Seungwoo;Lim, Kyungbae;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.169-170
    • /
    • 2016
  • 여러 분산 발전 시스템으로 구성된 마이크로그리드는 계통 연계 모드에서 부하의 수요에 담당하게 되고, 계통 사고가 발생할 시 독립 운전 모드로 동작을 해야 한다. 본 논문에서는 독립운전 모드 동작 시 제어 방식 중에서 유, 무효 전력제어를 통한 적절한 전력 분담을 실현하기 위한 드룹제어 방식을 다룬다. 이 방식은 선로 임피던스가 복합 성분으로 구성되어 있거나 불 평형 일 경우 여러 문제로 유,무효 전력 분담의 오차를 발생 시킨다. 이에 대하여 가상임피던스를 추가함으로써, 복합적 불 평형 임피던스에 기인한 유,무효 전력 분담의 오차를 해결 하여, 시스템의 유,무효 전력 분담을 개선 하고자 하였다. 또한, 비선형 부하 시 고조파의 문제를 비례-공진 제어기를 이용하여 고조파를 저감 할 수 있도록 하였다. 이에 PSIM 시뮬레이션과 실험을 통하여 검증하였다.

  • PDF

Droop Control for Parallel Inverters Using Virtual Inductor with load sharing and voltage regulation (병렬형 인버터의 부하 분담과 부하 전압 레귤레이션을 고려한 가상 인덕터 기반의 드룹 제어)

  • Kim, Dong Hwan;Jeon, Jaeryang;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.173-174
    • /
    • 2015
  • 복합 성분으로 구성 되어 있는 선로임피던스 하에서 인버터 병렬 운전을 위한 드룹 제어 방식을 다루고 있다. 드룹 제어 방식은 선로 임피던스가 복합 성분으로 구성되어 있는 경우 유무효 전력의 분담에 있어서 여러 가지 이유로 오차를 발생시킨다. 이러한 오차에 대한 대책으로 가상 임피던스의 적용은 전력 간섭성분 제어로 전력 분담의 오차는 해결되었다. 하지만 대전류가 흐르는 대용량 시스템에서는 가상 임피던스로 인한 전압 강하가 커지게 되므로 설정한 유효전력을 추종하지 못하게 된다. 본 논문에서는 위의 사항을 고려하여 복합 성분으로 구성 되고 불평형인 선로임피던스와 하에서 유무효전력 분담을 개선하고자 하였으며 제안한 드룹 제어 방식을 기존의 방식과 비교 하였다. 제안한 드룹 제어 방식의 전력 분담은 PSIM과 실험을 통해 검증되었다.

  • PDF

An Application of Driver's Critical Gap on a Changing Lane Assistance System for an Unprotected Left-turn (비보호 좌회전 보조를 목적으로 하는 차선 변경 보조 시스템에서의 임계간격 적용)

  • Jeong, Hwang Hun;Shin, Hee Young;Seo, Myoung Kook
    • Journal of Drive and Control
    • /
    • v.19 no.3
    • /
    • pp.47-52
    • /
    • 2022
  • The C-ITS (Cooperative-intelligent Transport System) is a driver assistance system that prevents car accidents and enhances traffic conditions, via sharing traffic information between vehicles and roadway infrastructures. A CLAS (changing lane assistance system) for unprotected left-turn, is a C-ITS that assists a driver with safely changing lanes. This system addresses a driver's critical gap, that enables the system to express a driver's uncertainty. A driver's critical gap is a time that can be used in a threshold, to change a lane or not. Unfortunately, a driver's critical gap is difficult to use in a CLAS directly. This paper addresses a driver's critical gap, and how it can be applied in a CLAS for an unprotected left-turn.

An Inherent Zero-Voltage and Zero-Current-Switching Full-Bridge Converter with No Additional Auxiliary Circuits

  • Wang, Jianhua;Ji, Baojian;Wang, Hongbo;Chen, Naifu;You, Jun
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.610-620
    • /
    • 2015
  • An inherent zero-voltage and zero-current-switching phase-shifted full-bridge converter with reverse-blocking insulated-gate bipolar transistor (IGBT) or non-punch-through IGBT is proposed in this paper. This converter not only ensures that the switches in the lagging leg works at zero-current switching, but also minimizes circulating conduction loss without any additional auxiliary circuits. A 1.2 kW hardware prototype is designed, fabricated, and tested to verify the proposed topology. The control loop design procedures with small-signal models are also presented. A simple, low-cost, and robust democratic current-sharing circuit is also introduced and verified in this study. The proposed converter is a suitable alternative for compact, cost-effective applications with high-voltage input.

Radio Resource Management Algorithm for Uplink Coordinated Cooperative Spatial Multiplexing (셀 간 협동 CSM에서 상향 링크 용량 개선을 위한 자원 할당 알고리즘)

  • Mun, Cheol;Jo, Han-Shin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.11
    • /
    • pp.1311-1317
    • /
    • 2010
  • In this paper, for a uplink space division multiple access system named cooperative spatial multiplexing(CSM), radio resource management(RRM) algorithms are proposed based on sharing uplink channel information among a serving base station(BS) and interfering BSs in a uplink coordinated wireless communication system. A constrained maximum transmit power algorithm is proposed for mobile station(MS) to limit uplink inter-cell interference(ICI). And joint scheduling algorithm among coordinated BSs is proposed to enhance uplink capacity through ICI mitigation by using channel information from interfering BSs. It is shown that the proposed RRM algorithm provides a considerable uplink capacity enhancement by effective ICI mitigation only with moderate complexity.

Quality of Service Tradeoff in Device to Device Communication Underlaid Cellular Infrastructure

  • Boabang, Francis;Hwang, Won-Joo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.591-593
    • /
    • 2016
  • Device-to-device (D2D) communications underlaid cellular infrastructure is an competitive local area services technology to promote spectrum usage for next generation cellular networks. These potential can only be tap through efficient interference coordination. Previous works only concentrated on interference from D2D pairs whiles interference from CUs to D2D pairs were neglected. This work focus on solving uplink interference problem emanating from multiple CUs sharing its resource with multiple D2D pairs. The base station (BS) acting as a supervisor selfishly institute a pricing scheme to manage the interference it experience from D2D pairs based on its Quality of service (QoS) requirement. D2D pairs following the supervisor make power allocation decisions considering the price from the BS in a non-cooperative game fashion. In order for the D2D pairs to also meet their QoS requirement, they suggest a price to the BS called discount price which reflects the interference they receive from the CUs. Finally, we analyze the proposed approach.

  • PDF

Interference Cancellation Scheme for Three-hop Cooperative Relay Networks

  • Zhang, Yinghua;Wang, Lei;Liu, Jian;Peng, Yunfeng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.9
    • /
    • pp.4446-4462
    • /
    • 2019
  • In this paper, we focus on interference cancellation for three-hop cognitive radio networks (CRNs) over Rayleigh fading channels. In CRNs, secondary users (SUs) are allowed to opportunistically utilize the licensed spectrum during the idle time of primary users (PUs) to achieve spectrum sharing. However, the SUs maybe power constrained to avoid interference and cover a very short transmission range. We here propose an interference cancellation scheme (ICS) for three-hop CRNs to prolong the transmission range of SUs and improve their transmission efficiency. In the proposed scheme, a flexible transmission protocol is adopted to cancel the interference at both secondary relays and destinations at the same time. And a closed-form expression for the secondary outage probability over Rayleigh fading channels is derived to measure the system performance. Simulation results show that the proposed scheme can significantly reduce the secondary outage probability and increase the secondary diversity in comparison with the traditional cases.