• Title/Summary/Keyword: Power quality measurement

Search Result 349, Processing Time 0.043 seconds

Analysis on the Characteristics of Voltage Unbalance Factor by Load Variations (부하 변동에 의한 전압불평형율의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.1
    • /
    • pp.47-53
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Voltage unbalance factor is mainly affected by load system rather than stable power system. Unbalanced voltage will draw a highly unbalanced current. As a result, the three-phase currents may differ considerably, thus resulting in an increased temperature rise in the machine. This paper presents a scheme on the characteristics of voltage and current unbalance factor under the load variation at the three phase 4-wire system. Load unbalance factor is measured by the power quality measurement apparatus and compared by the current unbalance factor. Two methods are indicated similar results. The voltage unbalance factor of the three-phase 4-wire system is approved by the field measurement. Each phase has an impedance each other by the unbalanced operation pattern and give rise to voltage unbalance.

New Techniques for Impedance Characteristics Measurement of Islanded Microgrid based on Stability Analysis

  • Hou, Lixiang;Zhuo, Fang;Shi, Hongtao
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1163-1175
    • /
    • 2016
  • In recent years, microgrids have been the focus of considerable attention in distributed energy distribution. Microgrids contain a large number of power electronic devices that can potentially cause negative impedance instability. Harmonic impedance is an important tool to analyze stability and power quality of microgrids. Harmonic impedance can also be used in harmonic source localization. Precise measurement of microgrid impedance and analysis of system stability with impedances are essential to increase stability. In this study, we introduce a new square wave current injection method for impedance measurement and stability analysis. First, three stability criteria based on impedance parameters are presented. Then, we present a new impedance measurement method for microgrids based on square wave current injection. By injecting an unbalanced line-to-line current between two lines of the AC system, the method determines all impedance information in the traditional synchronous reference frame d-q model. Finally, the microgrid impedances of each part and the overall microgrid are calculated to verify the measurement results. In the experiments, a simulation model of a three-phase AC microgrid is developed using PSCAD, and the AC system harmonic impedance measuring device is developed.

A Power Quality Analysis of a Photovoltaic System (태양광 발전설비 전력품질 분석)

  • Jung, Jong-Wook;Kim, Sun-Gu;Choi, Myeong-Il
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.579-584
    • /
    • 2009
  • This paper describes a power quality analysis of a photovoltaic generating systems. Prior to the power measurement, domestic and foreign codes related to the photovoltaic generating systems were briefly summarized. After constructing about 5 kW photovoltaic systems, input/output voltages and currents were measured to compare and analyze the power quality by the module type. Based on the measured values, a couple of factors such as active power, power factor, total harmonic distortion(THD) was calculated and analyzed.

Design and performance evaluation of portable electronic nose systems for freshness evaluation of meats (육류 신선도 판별을 위한 휴대용 전자코 시스템 설계 및 성능 평가)

  • Kim, Jae-Gone;Cho, Byoung-Kwan
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.525-532
    • /
    • 2011
  • The aim of this study was to develop a portable electronic nose system for freshness measurement of meats, which could be an alterative of subjective measurements of human nose and time-consuming measurements of conventional gas chromatograph methods. The portable electronic system was o optimized by comparing the measurement sensitivity and hardware efficiency, such as power consumption and dimension reduction throughout two stages of the prototypes. The electronic nose systems were constructed using an array of four different metal oxide semiconductor sensors. Two different configurations of sensor array with dimension were designed and compared the performance respectively. The final prototype of the system showed much improved performance on saving power consumption and dimension reduction without decrease of measurement sensitivity of pork freshness. The results show the potential of constructing a portable electronic system for the measurement of meat quality with high sensitivity and energy efficiency.

A DSP based Three Phase Power Quality Analyzer for Motor Drives (모터 구동장치를 위한 DSP기반 3상 전력품질분석 시스템)

  • 정영국
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.661-664
    • /
    • 2000
  • This paper presents a digital instrument for the power quality analysis in three phase power system where current waveform is non-sinusoidal. It is based on C31 DSP and on a special high-speed data acquisition system. Voltage and current waveforms are acquired and processed by using a simple average power algorithm, The paper also goes on to discuss the performance of an instrument prototype both in terms of accuracy and speed of measurement.

  • PDF

The study on the EIRP measurement methods considering Antenna Gain (안테나 이득을 고려한 EIRP 측정 방법에 관한 연구)

  • Kim, Dong-Ho;Choi, Dong-Geun;Shin, Chan-Soo;Sin, Ho-Seop;Kim, Nam
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.555-559
    • /
    • 2003
  • Recently, in accordance with the commercialization of novel radio frequency utilization technologies, the radiated power must be rigorously limited for the purpose of protection of wireless facilities against frequency jamming or interference and for maintaining the quality of communication service. At present, the output power is measured from the conducted power for the domestic measurement criterion but is not a real radiated power and inaccurate. So, it is peformed to survey the more precisely accurate measurement scheme and analyze its criterion and methodology in comparison with foreign one. As a result of surveying and analyzing, it is concluded that the U.S. and E.U. is actually using the measurement method in consideration of terms of the Equivalent Isotropic Radiated Power(EIRP) and Effective Radiated power(ERP). In case of the frequency below 1 GHz, the half wave-length dipole antenna is used to measure the ERP and above 1 GHz the horn antenna as a reference antenna is used to measure the EIRP. Therefore, for the domestic purpose it is also necessary to take EIRP and ERP into consideration as a measurement criterion in order to make an accurate measurement and regulation.

  • PDF

A Study on the Data Aquisition System for Power Quality Analysis of Load Equipment (부하설비의 전력품질 분석을 위한 데이터 획득시스템에 관한 연구)

  • Yu, Jae-Geun;Lee, Sang-Ik;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.92-94
    • /
    • 2007
  • In order to analyze voltage, current, electrical power, harmonics and so on of electrical load equipments, electrical power analysis by real measurement rather than mathematical modeling is necessary, and plan of countermeasure for efficient management, energy frugality and accident prevention of electrical equipments using it is possible. Especially, electrical power analysis by real measurement is indispensable in order to consider countermove of harmonic occurred by nonlinear load. So, in this paper, we developed DSP(Digital Signal Processor) based low price date aquisition system, and verified it's ability by performing measurement and analysis of electrical power and harmonic in the real power system.

  • PDF

Measures to Improve the Efficiency of the Portable Air Quality Measurement System

  • CHOI, Jong-Sun;CHO, Dong-Myung;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.5 no.3
    • /
    • pp.27-41
    • /
    • 2022
  • Purpose: In this study, pollutants generated in industrial areas were measured using a Portable Air Quality Measurement System(PAQMS). This study intends to examine in detail improvement measures and operational capabilities to operate a more efficient PAQMS. Research design, data and methodology: This study compares and analyzes the measurement values of the PAQMS and the measurement values of the national air quality measurement network. It is intended to develop a PAQMS corresponding to the data of the national measurement network by minimizing the errors that occur during comparative measurement and analysis and supplementing and improving the problems that occur during the current equipment calibration. Results: A PAQMS is an essential equipment for faster and more accurate measurement and analysis of pollutants in case of untimely measurement and civil complaints due to Micro Climate(local weather and environmental influences). Currently, there are many atmospheric measurement equipment in Korea, but only equipment for each item is produced and sold. Currently, these devices on the market must satisfy various conditions such as stable power, temperature, and humidity to calculate accurate measurement values. Conclusions: Therefore, there is no equipment that satisfies the conditions for performing detailed measurement in the field where accurate measurement is required. In this study, these field work conditions and contents for stable measurement were mentioned in the text.

Power Quality Measurement System of using PLC (전력선통신을 이용한 전력품질 측정시스템)

  • Hong, Duc-Pyo;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.90-92
    • /
    • 2005
  • As the developing of industry, the nonlinear equipments as inverter, converter, SMPS(Switching Mode Power Supply) and motor have been increased. But the sensitive electronic loads to the power quality, such as computer's and other electronic equipments, have been spreaded out very fast. Thus, the power quality (PQ) problems and the real time power quality monitoring (PQM) are one of the important issues industry and building area for the intelligent control of the systems. One of them, PQM using PLC(Power Line Communication) have good merits that can send and receive the PQ information without any new network line. This paper presents the PQM hardware and software to monitor the PQ information by using PLC that meets the categories of IEEE Std. 1159.

  • PDF

Quality Measurement of Data Processing by a Protocol Change of Power SCADA System (전력감시제어설비의 프로토콜 변경에 따른 데이터처리 품질측정)

  • Lee Yong-Doo;Choi Seong-Man;Yoo Cheol-Jung;Chang Ok-Bae
    • The KIPS Transactions:PartD
    • /
    • v.12D no.7 s.103
    • /
    • pp.1031-1038
    • /
    • 2005
  • In this paper, the maximum traffic quantity and actual traffic quantify of the data which are needed to grasp the statement of a system will be measured more accurately. A concrete quality measurement will be conducted by analysing a change of traffic quantity according to a protocol change and traffic under an overload condition when there is an accident. As a result can make an opportunity to maximize safety of power SCADA. Furthermore, future traffic quantity can be prospected by knowing current traffic quantity and grasping the rate of increase by the analysis and the information can be used as data to secure the band width in advance. It can make stable operation of power SCADA by arranging the limited network resources efficiently by information analysis of a network and expects more confidence.