• Title/Summary/Keyword: Power quality disturbance

Search Result 87, Processing Time 0.028 seconds

A Voltage Disturbance Detection Method for Computer Application Lods (컴퓨터 응용 부하들을 위한 전압 외란 검출 방법)

  • 이상훈;최재호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.6
    • /
    • pp.584-591
    • /
    • 2000
  • Power Quality Compensator(PQC) has been installed to protect the sensitive loads against the voltage disturbances, such as voltage sag and interruption. In general, static switch is used for the purpose of link between utility and PQC. So transfer operation of the static switch play a important part in the PQC. Many studies on the structure and control of PQC have been progressed in active, but these researches have been rarely mentioned about any voltage-disturbances-detection method to start the PQC operation. In this paper, a new voltage-disturbances-detection algorithm for computer application loads using the CBEMA/ITIC curve is proposed for transfer operation of the static switch. The proposed detection algorithm is implemented to get fast detecting time through the comparison of instantaneous 3-phase voltage values transferred to DC values in the synchronous reference frame with the operating reference values. To get the robust characteristics against the noise, a first order digital filter is designed. The magnitude falling and phase delay caused by the filter are compensated through the error normalizing and numerical analysis using transfer function, respectively. Finally, the validity of the proposed algorithm is proved by ACSL simulation and experimental results.

  • PDF

Line-Interactive DVR Using Multi-Level H-Bridge Inverter (멀티-레벨 H-Bridge 인버터를 이용한 Line-Interactive DVR)

  • Kang Dae-Wook;Woo Sung-Min;Kim Tae-Jin;Choi Chang-Ho;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.139-143
    • /
    • 2001
  • Recently, the interest on power quality has been hot issue. The equipments cause voltage disturbance and has become more sensitive to the voltage disturbance. This paper deals with 5-Level H-Bridge Line-Inter active Dynamic Voltage Restorer(LIDVR) system. The LIDVR has following advantages in comparison with the DVR with series injection transformer It has the power factor near to unity under normal source voltage, can compensate the harmonic current of the load and the instant interruption, and has the fast response. First, the construction, the operation mode and algebraic modeling of LIDVR are reviewed. And then a voltage controller is proposed to get sinusoidal load voltage with constant amplitude. To find PWM method suitable for H-Bridge converter, two PWM methods are compared and analyzed. Finally, simulation results verify the proposed 5-level H-Bridge LIDVR system.

  • PDF

The SMPS with a Bulit-in UPS for Computer (UPS를 내장한 컴퓨터용 SMPS)

  • 이성룡;전칠환;이수원;고성훈;권혁대
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.8
    • /
    • pp.495-499
    • /
    • 2004
  • UPS(Uninterruptible Power Supply) have been used to improve power source quality as well as to protect critical loads such as computer, industrial system, medical equipment, etc, by providing clean and uninterrupted power under power supply disturbance or interruptions. But UPS is bulky because batteries. So, a UPS size issue has received the attention in the power electronics industry. This paper proposed an implementation of the computer power supply with a bulit-in UPS controlled by the one-chip microprocessor to minimize UPS size. The experimental results verified the proposed SMPS with a bulit-in UPS for computer.

Power disturbance measurement system using discrete wavelet transform (이산웨이블릿을 이용한 전력외란 측정 시스템)

  • 이진목;김홍균;최재호;이상훈
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.527-533
    • /
    • 2003
  • Recently, need of power stability and reliability has been increased as the spread of the sensitive electronic loads. Therefore, the power quality(PQ) problems become the hot Issue of public interest in these days. Many kinds of algorithms have been studied for the monitoring of PQ problems using the monitoring algorithms with RMS or FFT scheme, but it is still not enough to measure all of the PQ problems. This paper proposed the application of discrete wavelet transform(WT) for the PQ problems monitoring with the Introduction of WT theory, and the design of PQ monitoring data acquisition system Is described with some experimental results to verify the validity of the proposed PQ monitoring algorithm.

Comparison of Three Active-Frequency-Drift Islanding Detection Methods for Single-Phase Grid-Connected Inverters

  • Kan, Jia-rong;Jiang, Hui;Tang, Yu;Wu, Dong-chun;Wu, Yun-ya;Wu, Jiang
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.509-518
    • /
    • 2019
  • A novel islanding detection method is proposed in this paper. It is based on a frequency drooping PLL, which was presented in a previous work. The cause of errors in the non-detection zone (NDZ) of conventional frequency disturbance islanding detection methods (IDM) is analyzed. A frequency drooping phase-locked-loop (FD-PLL) is introduced into a single-phase grid-connected inverter (SPGCI), which can guarantee that grid current is in phase with the grid voltage. A novel FD-PLL IDM is proposed by improving this PLL. In order to verify the performance of the proposed FD-PLL IDM, a full performance comparison between the proposed IDM and typical existing active frequency drift IDMs is carried out, which includes both dynamic performance and steady performance. With the same NDZ, the total harmonic distortion of the grid-current in the dynamic process and steady state is analyzed. The proposed FD-PLL IDM, regardless of the dynamic or steady process, has the best power quality. Experimental and simulation results verify that the proposed FD-PLL IDM has excellent performance.

The Influence of Cancer Fatigue, Quality of Sleep, and Environmental Sleep Disturbance on Comfort in Hospitalized Cancer Patients (입원한 암환자의 암피로, 수면의 질 및 환경적 수면장애가 안위에 미치는 영향)

  • Kim, Hee-Jin;Chang, Hee-Kyung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.643-653
    • /
    • 2020
  • This study is a descriptive research study to identify the relationship between cancer fatigue, quality of sleep, environmental sleep disturbance, and comfort perceived by hospitalized cancer patients. Data were collected with structured questionnaires from 113 cancer patients from a university hospital in J city, Gyengnam, from September 17 to November 5, 2019, and analyzed using SPSS 21.0, using independent t-test, one-way ANOVA, Scheffé test, Pearson's correlation coefficient, and stepwise multiple regression. The subjects' Comfort is significantly different depending on education level, Cancerous type, Radiation treatment status, Usual exercise status. The result showed that comfort was negatively correlated with cancer fatigue(r=-.609, p<.001), quality of sleep(r=-.478, p<.001), and environmental sleep disturbance(r=-.297, p=.001). The variables that had a significant effect on comfort were cancer fatigue(β=-.42, p<.001), subjective quality of sleep(β=-.30, p=.001), and cancer type(β=-.18, p<.015), and the explanatory power was 46.1%(F=27.24, p<.001). Based on these results, it is necessary to develop a program to improve the quality of sleep and to reduce the cancer fatigue by cooperating with medical and nursing staff in multidisciplinary ways to enhance the comfort of hospitalized cancer patients.

Calculation of the Harmonic Emission Limit for low-Voltage Electrical Equipment (국내 저압 전기기기의 고조파 유출 제한값 산정)

  • Kang, Moon-Ho;Song, Yang-Hoi;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.56-61
    • /
    • 2008
  • Because the harmonic disturbance characteristic which makes voltage drop and the deterioration of instantaneous power quality in electrical power system overheats the NGR and the customer capacitor and malfunctions the OCGR and AMR, it is necessary for electric power company to take active measures to reduce this disturbance. International Electrotechnical Commission(IEC) 61000-3-2 specifies limits for harmonic current emissions generated by low voltage(LV) electrical equipment whose input current $\leq$ 16(A) per phase. Analysis shows that limits for Class A equipment in IEC are calculated using the reference impedance of LV system and maximum permissible voltage and limits for other Classes are also calculated based on limits for Class A. Therefore we have calculated four(4) internal limits for LV electrical equipment using the korea reference impedance and maximum permissible voltage in this paper.

Sag-Swell Generator for Power Quality Disturbance of Dynamic UPS System (전력품질을 고려한 다이나믹 UPS 시스템의 Sag-Swell 발생기)

  • Ahn J.S.;Choi K.J.;Chun T.W.;Nho E.C;Kim I.D.;Kim H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.193-196
    • /
    • 2003
  • This paper describes a new Sag-Swell generator for the test of custom power devices such as UPS, DYR, DSTATCOM, 5575, etc. The proposed science has good features of simple structure, high reliability, wide range of Sag and Swell variation, and easy control. Outage, harmonic distortion, notches, and voltage unbalance also can be generated. The operation principle of the proposed scheme is described and verified through simulations.

  • PDF

Series Voltage Compensation Systems for Voltage Sag by Using an Environmentally Friendly Ultra-capacitor (친환경 Ultra-capacitor에 의한 순시전압강하의 직렬전압보상 시스템)

  • Shon, Jin-Geun;Jeon, Hee-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.763-769
    • /
    • 2009
  • A series voltage compensation(SVC) system is a power-electronics controller that can protect sensitive loads from disturbance in the supply system. Especially, voltage sags are considered the dominant disturbances affecting the power quality. This paper dealt with a system of off-line type voltage sag compensation by using a bi-directional DC/DC converter of environmentally friendly ultra-capacitor. This capacitor is attached to the DC link of SVC through the high-efficiency DC/DC converter in order to compensate the DC link voltage drop during short-term power interruption as voltage sags. Therefore, in this paper, a DC/DC converter to control high-efficiency energy of ultra-capacitor and voltage sag detection algorithm of off-line type SVC systems are newly introduced. According to the results of experimental of prototype system, it is verified that the proposed system has effectiveness of voltage sag compensation using an ultra-capacitor.

A Power Disturbance Classification System using Wavelet-Based Neural Network (웨이블릿 기반의 뉴럴네트웍을 이용한 전원의 왜란분류 시스템)

  • Kim, Hong-Kyun;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.487-489
    • /
    • 2005
  • This paper presents a wavelet-based neural network technology for the detection and classification of the short durations type of power quality disturbances. Transients happen during very short durations to the nano- and microsecond. Thus, a method for detecting and classifying transient signals at the same time and In an automatic combines the properties of the wavelet transform and the advantages of neural networks. Especially, the additional feature extraction to improve the recognition rate is considered. The configuration of the hardware of TMS320C6711 DSP based with 16 channel 20Mhz sampling rate A/D(Analog to Digital) converter and some case studies are described.

  • PDF