• Title/Summary/Keyword: Power performance test

Search Result 2,662, Processing Time 0.028 seconds

Phytochemicals and Antioxidant Activity of Codonopsis lanceolata Leaves (더덕 잎의 파이토케미컬(phytochemicals)과 항산화 활성)

  • Kim, Gi Ho;Kim, Na Yeon;Kang, Shin-Ho;Lee, Hwa Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.5
    • /
    • pp.680-685
    • /
    • 2015
  • Phytochemicals in Codonopsis lanceolata leaves were saponins, triterpenes, tannins, and flavonoids, not alkaloids. The levels of total polyphenols and flavonoids in Codonopsis lanceolata leaves were measured to evaluate the antioxidant activity. C. lanceolata leaves showed strong 2, 2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging activity and potent reducing power. In addition, C. lanceolata leaf extracts inhibited production of nitric oxide (NO) in lipopolysaccharide (LPS)-activated RAW 264.7 cells. To examine active phytochemical for antioxidant activity, aglycone fraction of C. lanceolata leaves was analyzed by high performance liquid chromatography (HPLC). Luteolin was identified as a main component of aglycone fraction and showed potent antioxidant activity as determined by a DPPH radical scavenging assay and reducing power test. These results suggest that C. lanceolata leaves are a good source of antioxidants.

Design of a Neural Network PI Controller for F/M of Heavy Water Reactor Actuator Pressure (신경회로망과 PI제어기를 이용한 중수로 핵연료 교체 로봇의 구동압력 제어)

  • Lim, Dae-Yeong;Lee, Chang-Goo;Kim, Young-Baik;Kim, Young-Chul;Chong, Kil-To
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.1255-1262
    • /
    • 2012
  • Look into the nuclear power plant of Wolsong currently, it is controlled in order to required operating pressure with PI controller. PI controller has a simple structure and satisfy design requirements to gain setting. However, It is difficult to control without changing the gain from produce changes in parameters such as loss of the valves and the pipes. To solve these problems, the dynamic change of the PI controller gain, or to compensate for the PI controller output is desirable to configure the controller. The aim of this research and development in the parameter variations can be controlled to a stable controller design which is reduced an error and a vibration. Proposed PI/NN control techniques is the PI controller and the neural network controller that combines a parallel and the neural network controller part is compensated output of the controller for changes in the parameters were designed to be robust. To directly evaluate the controller performance can be difficult to test in real processes to reflect the characteristics of the process. Therefore, we develope the simulator model using the real process data and simulation results when compared with the simulated process characteristics that showed changes in the parameters. As a result the PI/NN controller error and was confirmed to reduce vibrations.

The Study of Isokinetic Exercise Test of Trunk Rotation of 20's Male College Students (20대 남자대학생의 몸통회전에 대한 등속성운동 검사에 관한 연구)

  • Choi, Byung-Ok
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.21-25
    • /
    • 2006
  • Objective: The purposes of this study are to provide fundamental data and a rehabilitation program in physical therapy. It has been operated by 30 male college students for lumbar isokinetic exercises. Method : Subjects have been carried out in an experiment by Biodex system operating isokinetic torso rotation. This performance was activated by left rotation after right rotation repeatedly. Results: 1. The mean peak torques at $60^{\circ}$/sec were $95.6{\pm}20.62$ (Rt) and $93.84{\pm}18.41$ (Lt). 2. The mean peak torques/body weight at $60^{\circ}$/sec were $69.28{\pm}28.31$ (Rt) and $67.07{\pm}27.04$ (Lt). 3. The total works in right side at $60^{\circ}$/sec and $180^{\circ}$/sec were $492.21{\pm}92.37$, $1294.97{\pm}278.96$ and in left side at $60^{\circ}$/sec and $180^{\circ}$/sec were $515.78{\pm}109.47$, $1443.74{\pm}329.67$. 4. The work to body weight ratio at $60^{\circ}$/sec was $78.30{\pm}32.37$ (Rt) and $79.93{\pm}37.30$ (Lt). 5. The average powers in right side at $60^{\circ}$/sec and $180^{\circ}$/sec were $76.75{\pm}16.69$, $117.19{\pm}29.94$ and in left side at $60^{\circ}$/sec and $180^{\circ}$/sec were $78.54{\pm}18.58$, $125.39{\pm}32.90$. 6. The work fatigue at $180^{\circ}$/sec was $21.76{\pm}14.82$ (Rt) and $19.66{\pm}26.23$ (Lt). Conclusion: In right side and left side, there was no significant difference in peak torque. peak torque/body weight, work to body-weight ratio, average power of trunk rotators at $60^{\circ}$/sec(p<0.05). However there was a significant difference in the total work of trunk rotators at $60^{\circ}$/sec(p>0.05). Also there was a significant difference in the average of trunk rotators at $180^{\circ}$/sec(p>0.05).

  • PDF

Performance Evaluation of Magnesium Bipolar Plate in Lightweight PEM Fuel Cell Stack for UAV (무인기용 경량 PEM 연료전지 스택용 마그네슘 분리판의 성능평가)

  • Park, To-Soon;Oh, Ji-Hyun;Ryu, Tae-Kyu;Kwon, Se-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.10
    • /
    • pp.788-795
    • /
    • 2013
  • A magnesium bipolar plate whose surface was protected by thinly deposited silver layer was investigated as an alternative to existing graphite bipolar plate of PEM fuel cells. Thin silver layer of $3{\mu}m$ was deposited on a magnesium alloy substrate by physical vapor deposition (PVD) method in an environment of $180^{\circ}C$. A number of tests were conducted on the fabricated magnesium based bipolar plates to determine their suitability for use in PEM fuel cell stacks. The test on corrosion resistance in the same pH condition as in a PEM operation demonstrated the layer protected the magnesium alloy substrate, while unprotected substrate suffered from severe corrosion. The contact resistance of the fabricated bipolar plate was less than $20m{\Omega}-cm^2$ which was superior to the conventional bipolar plates. A single cell was constructed using the fabricated bipolar plates and power output was measured. Due to the enhanced conductivity caused by low contact resistance, slight increase was observed in current density and output voltage. With low density of the magnesium substrate and ease on machining, the weight reduction of the stack of 30~40 % is possible to produce the same power output.

Development of a Software to Evaluate the CPES(Cable Penetration Fire Stop) System in Nuclear Power Plane I (원자력발전소 케이블관통부 충전시스템 평가용 소프트웨어 개발 I)

  • 윤종필;권성필;조재규;윤인섭
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.24-30
    • /
    • 2004
  • In this work the dynamic heat transfer occurring in a cable penetration fire stop system built in the firewall of nuclear power plants is three-dimensionally investigated to develop a test-simulator that can be used to verify effectiveness of the sealants. Here was carried out an experiment to observe the heat transfer in the cable penetration fire stop system made of DOW CORNING products. The dynamic heat transfer occurring in the fire stop system is formulated in a parabolic partial differential equation subjected to a set of initial and boundary conditions. And it was modeled, simulated, and analyzed. The simulation results were illustrated in three-dimensional graphics and were compared with experimental data. Through the simulations, it was shown clearly that the temperature distribution was influenced very much by the number, position, and temperature of the cable streams. It also was found that the dynamic heat transfer through the cable streams was one of the most dominant factors, and the feature of heat conduction could be understood as an unsteady-state process. It is certain that these numerical results are useful for making a performance-based design for the cable penetration fire stop system.

Method for evaluating the safety performance and protection ability of the mobile steel protective wall during the high-explosive ammunition test (고폭탄 탄약시험 간 이동형 강재 방호벽의 안전성능 판단 및 유효 방호력 평가 방법)

  • Jeon, In-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.573-582
    • /
    • 2021
  • In this study, a series of processes for evaluating the effective protection against barriers that should be equipped in institutions that perform reliability tests on high-risk ammunition, such as high-explosive ammunition, were introduced. The impact that high-explosive bombs can have on personnel includes damage to the eardrum and lungs caused by explosion overpressure and penetrating wounds that can be received by fragments generated simultaneously with the explosion. Therefore, a high-explosive with COMP B explosives as its contents were set up, and an explosion protection theory investigation to calculate the degree of damage, numerical calculations and simulations were performed to verify the protection power. A numerical calculation revealed the maximum explosion overpressure on the protective wall when the high-explosive exploded and the penetration force of the fragment against a 50 mm-thick protective wall to be 77.74 kPa and 41.34 mm, respectively. In the simulation verification using AUTODYN, the maximum explosion overpressures affecting the firewall and personnel were 56.68 kPa and 18.175 kPa, respectively, and the penetration of fragments was 35.56 mm. This figure is lower than the human damage limit, and it was judged that the protective power of the barrier would be effective.

Analysis and verification of the characteristic of a compact free-flooded ring transducer made of single crystals (압전단결정을 이용한 소형 free-flooded ring 트랜스듀서의 성능 특성 예측 및 검증)

  • Im, Jongbeom;Yoon, Hongwoo;Kwon, Byungjin;Kim, Kyungseop;Lee, Jeongmin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.3
    • /
    • pp.278-286
    • /
    • 2022
  • In this study, a 33-mode Free-Flooded Ring (FFR) transducer was designed to apply piezoelectric single crystal PIN-PMN-PT, which has high piezoelectric constants and electromechanical coupling coefficient. To ensure low-frequency high transmitting sensitivity characteristics with a small size of FFR transducer, the commercial FFR transducer based on piezoelectric ceramics was compared. To develop the FFR transducer with broadband characteristics, a piezoelectric segmented ring structure inserted with inactive elements was applied. The oil-filled structure was applied to minimize the change of acoustic characteristics of the ring transducer. It was verified that the transmitting voltage response, underwater impedance, and beam pattern matched the finite element numerical simulation results well through an acoustic test. The difference in the transmitting voltage response between the measured and the simulated results is about 1.3 dB in cavity mode and about 0.3 dB in radial mode. The fabricated FFR transducer had a higher transmitting voltage response compared to the commercial transducer, but the diameter was reduced by about 17 %. From this study, it was confirmed that the feasibility of a single crystal-applied FFR transducer with compact size and high-power characteristics. The effectiveness of the performance prediction by simulation was also confirmed.

Development of Screw-Type Handy Earth Auger for an Improved Digging Efficiency(I) - Design and Manufacture - (토양굴취력이 향상된 스크류형 경량 식혈기 개발(I) - 설계 및 제작 -)

  • Kim, Jin Hyun;Lee, Jae Hyun;Kim, Ki Dong;Ko, Chi Woong;Kim, Dong Geun
    • Journal of agriculture & life science
    • /
    • v.50 no.3
    • /
    • pp.31-41
    • /
    • 2016
  • This study was conducted to develop a handy earth auger for use in sloppy and rugged forest terrains in order to reduce labor cost which comprises a major part of the production costs in forest afforestation projects. The first prototype is developed consist of two parts, the soil-digging screw and the battery power source. The specifications of the first prototype screw are: length of 170mm, a top diameter of 60mm, bottom diameter of 47mm, 23° angle for each helix, and a 50mm awl-head tip. The use of a single line of screw was selected for reduced weight. In addition, a power source of rotary DC Motor(WD-6G2425, WONILL, Korea) with a maximum torque of 30kgf-cm, rotation of 20-30rpm, K6G30C decelerator with a reduction ratio of 30:1 which could be used with no load for 48 was operated. In consideration of its weight, a lithium battery was utilized in line with the goal of developing a lightweight auger. In order to evaluate the performance of the first prototype, test sites were selected as 6 areas. The rotational force was found to be highest in area A(Solid area), followed by areas F(Mounted slope 40° area) and E(Mounted slope 30° area). It was also observed that in general, the rotational force increased along with the increase in soil depth with the maximum rotational force recorded at 10cm.

Verification Test of High-Stability SMEs Using Technology Appraisal Items (기술력 평가항목을 이용한 고안정성 중소기업 판별력 검증)

  • Jun-won Lee
    • Information Systems Review
    • /
    • v.20 no.4
    • /
    • pp.79-96
    • /
    • 2018
  • This study started by focusing on the internalization of the technology appraisal model into the credit rating model to increase the discriminative power of the credit rating model not only for SMEs but also for all companies, reflecting the items related to the financial stability of the enterprises among the technology appraisal items. Therefore, it is aimed to verify whether the technology appraisal model can be applied to identify high-stability SMEs in advance. We classified companies into industries (manufacturing vs. non-manufacturing) and the age of company (initial vs. non-initial), and defined as a high-stability company that has achieved an average debt ratio less than 1/2 of the group for three years. The C5.0 was applied to verify the discriminant power of the model. As a result of the analysis, there is a difference in importance according to the type of industry and the age of company at the sub-item level, but in the mid-item level the R&D capability was a key variable for discriminating high-stability SMEs. In the early stage of establishment, the funding capacity (diversification of funding methods, capital structure and capital cost which taking into account profitability) is an important variable in financial stability. However, we concluded that technology development infrastructure, which enables continuous performance as the age of company increase, becomes an important variable affecting financial stability. The classification accuracy of the model according to the age of company and industry is 71~91%, and it is confirmed that it is possible to identify high-stability SMEs by using technology appraisal items.

Effects of critical thinking disposition, stress of clinical practice and self-confidence in performance of core nursing skill on nursing student's adapting to clinical practice (간호대학생의 비판적 사고성향, 임상실습 스트레스 및 핵심기본간호술 자신감이 임상실습 적응에 미치는 영향)

  • Jang, Young-Mi;Park, YeonHee
    • Journal of Industrial Convergence
    • /
    • v.18 no.4
    • /
    • pp.77-86
    • /
    • 2020
  • This study is a descriptive research study to grasp the critical thinking tendency, clinical practice stress, core basic nursing confidence, and degree of adaptation to clinical practice in nursing students. From June to July 2019, 207 students in the fourth year of nursing college were surveyed through their own questionnaire. Collected data were analyzed by t-test, ANOVA and multiple regression analysis using SPSS/WIN v24.0. The negative correlation between clinical practice stress and critical thinking tendency(r=-.18, p=.010). The core self-confidence practice self-confidence showed a positive correlation with critical thinking tendency(r=.25, p<.001), and a negative correlation with clinical practice stress(r=-.17, p=.017). Adaptation to clinical practice showed a positive correlation with clinical practice stress(r=.44, p<.001), and the factor influencing clinical practice adaptation was stress(β=.40) (F=18.34, p<.001), and the explanatory power was about 23.1%. As mentioned above, stress brings a positive change to clinical practice, so it is necessary to identify stress factors received from clinical practice of nursing college students and reflect them in curriculum development.