• 제목/요약/키워드: Power meter

검색결과 530건 처리시간 0.027초

LSTM과 GRU 딥러닝 IoT 파워미터 기반의 단기 전력사용량 예측 (Short-term Power Consumption Forecasting Based on IoT Power Meter with LSTM and GRU Deep Learning)

  • 이선민;선영규;이지영;이동구;조은일;박대현;김용범;심이삭;김진영
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권5호
    • /
    • pp.79-85
    • /
    • 2019
  • 본 연구에서는 Long Short Term Memory (LSTM) 신경망과 Gated Recurrent Unit(GRU) 신경망을 Internet of Things (IoT) 파워미터에 적용하여 단기 전력사용량 예측방법을 제안하고, 실제 가정의 전력사용량 데이터를 토대로 예측 성능을 분석한다. 성능평가 지표로써 Mean Absolute Error (MAE), Mean Absolute Percentage Error (MAPE), Mean Percentage Error (MPE), Mean Squared Error (MSE), Root Mean Squared Error (RMSE)를 이용한다. 실험 결과는 GRU 기반의 모델이 LSTM 기반의 모델에 비해 MAPE 기준으로 4.52%, MPE 기준으로 5.59%만큼의 성능개선을 보였다.

차세대 디지털 적산전력계에 기반한 배전원격관리 시스템 설계 (Design of DRMS(Distribution Remote Management System) Based on Advanced Digital Kwh-Meter)

  • 고윤석;이경호;윤상문;서성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.241-243
    • /
    • 2002
  • This paper proposes a DRMS(Distribution Remote Management System) based on the advanced digital kwh-meter. The proposed URMS is designed so as to be able to collect the voltage management data, the load management data as well as the used kwh data from advanced kwh-meter remotelly. It makes the integrated management of distribution system possible and enhances highly the economics of the existing remote meter-reading system based on the only used kwh-data. Also it can improve highly the quality of power supplied to the electric customer by minimizing the volt age management cost and by enhancing the efficiency of load management.

  • PDF

공급압력 변화에 의한 공기압 실린더 구동장치의 소비에너지 변화량 추정 방법 (A Method of Estimation of Energy Consumption according to a Supply Pressure for Pneumatic Cylinder Driving Apparatus)

  • 장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권2호
    • /
    • pp.15-20
    • /
    • 2012
  • Pneumatic cylinder meter-out driving apparatus is used widely because it is clean, lightweight, and can be easily serviced. In this study an estimation method of energy consumption for pneumatic cylinder meter-out driving apparatus is proposed. The proposed method is derived from state equation and energy equation of air, and, the equation of motion of a moving part of a pneumatic cylinder reflecting the characteristics of the meter-out driving. The effectiveness of the proposed method is proved by simulation study and it demonstrates that the proposed method can evaluate the energy consumption quickly and easily when the parameters of the driving apparatus are changed.

Power Quality Monitoring System with a New Distributed Monitoring Structure

  • Won, Dong-Jun;Chung, Il-Yop;Kim, Joong-Moon;Ahn, Seon-Ju;Moon, Seung-Il;Seo, Jang-Cheol;Choe, Jong-Woong
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권4호
    • /
    • pp.214-220
    • /
    • 2004
  • Power quality monitoring is the cornerstone for power quality analysis, diagnosis and improvement. The measurement of power quality (PQ) evolves from instantaneous metering to continuous monitoring. Furthermore, recent technologies enable us to construct more flexible, reliable, rapid and economical power quality monitoring system (PQMS). Therefore, this paper presents an improved PQMS with a new distributed monitoring structure. The proposed PQMS consists of a PQ meter, PQ analyzer and GUI. The PQ meter only collects raw data and the PQ analyzer performs power quality analysis. It has several advantages compared to conventional structures in economic efficiency, modularity, speed, etc. PQ monitoring algorithms to catch steady-state trends and to detect PQ events are also adapted to the proposed structure. Using the proposed structure and monitoring algorithm, a prototype PQMS is constructed and real-time testing is performed.

12개 다이오드 레이저를 활용하는 레이저 복사출력계 교정시스템 개발 (Development of Laser Power Meter Calibration System with 12-diode Laser Sources)

  • 이강희;유재근;배인호;박성종;이동훈
    • 한국광학회지
    • /
    • 제35권2호
    • /
    • pp.61-70
    • /
    • 2024
  • 400 nm부터 1,600 nm까지의 파장 영역에서 단일모드 광섬유에 결합된 12개의 다이오드 레이저 광원를 기반으로 하는 레이저 복사출력계 교정시스템을 소개한다. 본 시스템은 복사출력 측정위치에서 레이저 출력요동을 최소화하였고 모든 광원에 대해 비슷한 빔 크기를 갖는다. 또한 감응도의 비균일도 및 비선형성을 최소화하기 위해 적분구 기준기를 사용하였다. 이 교정시스템의 최소 측정불확도는 대부분의 레이저 파장에서 1.1% (k=2)로 추정된다.

Detection Limit of a NaI(Tl) Survey Meter to Measure 131I Accumulation in Thyroid Glands of Children after a Nuclear Power Plant Accident

  • Takahiro Kitajima;Michiaki Kai
    • Journal of Radiation Protection and Research
    • /
    • 제48권3호
    • /
    • pp.131-143
    • /
    • 2023
  • Background: This study examined the detection limit of thyroid screening monitoring conducted at the time of the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident in 2011 using a Monte Carlo simulation. Materials and Methods: We calculated the detection limit of a NaI(Tl) survey meter to measure 131I accumulation in the thyroid gland of children. Mathematical phantoms of 1- and 5-year-old children were developed in the simulation of the Particle and Heavy Ion Transport code System code. Contamination of the body surface with eight radionuclides found after the FDNPP accident was assumed to have been deposited on the neck and shoulder area. Results and Discussion: The detection limit was calculated as a function of ambient dose rate. In the case of 40 Bq/cm2 contamination on the body surface of the neck, the present simulations showed that residual thyroid radioactivity corresponding to thyroid dose of 100 mSv can be detected within 21 days after intake at the ambient dose rate of 0.2 µSv/hr and within 11 days in the case of 2.0 µSv/hr. When a time constant of 10 seconds was used at the dose rate of 0.2 µSv/hr, the estimated survey meter output error was 5%. Evaluation of the effect of individual differences in the location of the thyroid gland confirmed that the measured value would decrease by approximately 6% for a height difference of ±1 cm and increase by approximately 65% for a depth of 1 cm. Conclusion: In the event of a nuclear disaster, simple measurements carried out using a NaI(Tl) scintillation survey meter remain effective for assessing 131I intake. However, it should be noted that the presence of short-half-life radioactive materials on the body surface affects the detection limit.

Anomaly detection of smart metering system for power management with battery storage system/electric vehicle

  • Sangkeum Lee;Sarvar Hussain Nengroo;Hojun Jin;Yoonmee Doh;Chungho Lee;Taewook Heo;Dongsoo Har
    • ETRI Journal
    • /
    • 제45권4호
    • /
    • pp.650-665
    • /
    • 2023
  • A novel smart metering technique capable of anomaly detection was proposed for real-time home power management system. Smart meter data generated in real-time were obtained from 900 households of single apartments. To detect outliers and missing values in smart meter data, a deep learning model, the autoencoder, consisting of a graph convolutional network and bidirectional long short-term memory network, was applied to the smart metering technique. Power management based on the smart metering technique was executed by multi-objective optimization in the presence of a battery storage system and an electric vehicle. The results of the power management employing the proposed smart metering technique indicate a reduction in electricity cost and amount of power supplied by the grid compared to the results of power management without anomaly detection.

ANSI C12.22 국제 통신 프로토콜이 적용된 스마트미터 개발 (Development of a Smart meter Applying the ANSI C12.22 International Communication Protocols)

  • 이상일
    • 한국정보통신학회논문지
    • /
    • 제17권12호
    • /
    • pp.2952-2959
    • /
    • 2013
  • 본 논문에서는 국제 통신 프로토콜이 적용된 스마트미터를 개발하였다. 스마트미터는 전력 공급 사업자와의 데이터 교환을 위해 양방향 통신 및 제어 기술, 전기 기기의 등록 및 해제를 위한 통신 프로토콜이 요구된다. 스마트미터의 통신 프로토콜은 미국과 유럽을 중심으로 표준화가 진행되고 있으며, 본 논문에서 제안하는 스마트미터의 통신 프로토콜은 북미방식인 ANSI C12.22 표준을 채택하여 적용하였다. 스마트미터는 또한 전력 사용자에게도 실시간으로 소비 전력 정보와 요금 정보를 제공해야 하며, 사용자는 이 정보를 바탕으로 적절하게 수요반응을 할 수 있어야한다. 본 논문에서는 스마트미터에서 측정되는 전력량이 실시간으로 사용자에게도 보고될 수 있도록 하였으며, IHD(In Home Display)를 윈도우즈 소프트웨어로 구현하여 개발된 스마트미터와의 연동을 실현하였다.

구조해석 기반 동결팽창압 흡수용 수도미터 개발 (Development of Water Meters for Frozen Inflation Pressure Absorption Based on Structural Analysis)

  • 김국일;안상병;이병선;홍성택
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.314-316
    • /
    • 2022
  • 수도계량기는 사용자가 사용하는 물의 양을 계측하는 기기로 계량안정성 관리가 필요하다. 하지만 겨울철 한파로 인해 계량기 내부의 물이 얼음으로 상변화하며 약 9%의 체적이 커지게 되며 계량기의 파손이 발생된다. 기존 동파방지용 수도미터 동파방지 기술은 크게 세 가지로 보호통 내부에 열을 공급하는 방법, 단열을 위한 수도미터 외부 보호방법, 수도계량기에 동파방지 장치를 설치하는 방법으로 나뉜다. 기술개발 제품의 상용화를 위하여 구조를 최대한 변형시키지 않으며 외부전원이 필요하지 않은 기술을 개발하는데 목적이 있다. 따라서, 영하의 온도에서 수도계량기에 가해지는 내부압력을 해석하여 동파 취약부위를 확인하고 파손을 방지하기 위해 내부 압력을 감소시킬 수 있는 동파방지 효과가 우수한 수도계량기를 개발하고자 한다.

  • PDF