• Title/Summary/Keyword: Power meter

Search Result 530, Processing Time 0.026 seconds

Security Monitoring System for Apartment House Building Using Paver Line Carrier (전력선 통신을 이용한 집단주택 안전관리 시스템)

  • Kim, In-Soo;Kim, Kwan-Ho;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.476-478
    • /
    • 1993
  • Instead of installing new communication wiring to each house in the apartment house building. the power distribution network. which is already installed in the building. can be use as communication medium. In a safty management, by adoption of power line communication system, at remote we can monitor safty related sensors such as fire, gas leakage, burglar intrusion and emergency call which are located at each house. From this viewpoint, we developed security monitoring system for apartment house building using power lines. Security monitoring system consists of Power Line Communication-Sub Controller (PLC-SC). Power Line Communication-Main Controller (PLC-MC) and Management System (MS). Between a PLC-MC and a PLC-SC, the transmission rate is 1200 bps in power lines and modulation technique is frequency shirt keying (FSK). In between a PLC-MC and a MS, the transmission rate is 1200 bps in communication line (RS-485). As a result of this research. transmission loss is 0.1dB per meter of intrabuilding distribution network. Transmission can be reach in 250 meters. So it is enough to communicate for security monitoring system in apartment house building.

  • PDF

A Study on the Development of Electric Signal Measuring Device Using a Smart Phone (스마트 폰을 이용한 전기신호 측정기 개발에 관한 연구)

  • Son, Young-Dal;Eun, Chang-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.11
    • /
    • pp.9-17
    • /
    • 2017
  • In this paper, we propose a method to develop a multimeter which is used for measuring electric signals in industrial field by using battery and display of smart phone. Most of the multimeters that are linked to existing smartphones are connected to Bluetooth, which is inconvenient for battery use and low in measurement accuracy. To improve this, we developed smart multimeter that can supply power and data at the same time by USB OTG method which can be used by sharing the power of smartphone. We also developed a smart multimeter that can measure resistance, DC voltage, current, AC voltage and current. Developed an Android app with a button that displays measurement data and can select the type of electric signal to be measured, and tests whether the manufactured system is operating normally or not. Respectively.The results of this study confirm that it is possible to fabricate a smart meter that has equal or better performance compared to existing instruments and does not require a separate power source or display, and it is expected to be a reference for the development of various smart instruments in the future.

The Effect of Pressure and Hose Length on the Travelling Distance of Particles in Power Sprayer (토출압력(吐出壓力) 및 호오스길이가 도달성(到達性)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Kwon, Soon Hong;Choi, Kyu Hong
    • Journal of Biosystems Engineering
    • /
    • v.7 no.2
    • /
    • pp.30-35
    • /
    • 1983
  • To investigate the factors affecting the transportability of spray droplets, the maximum distance, the effective distance, the ratio of even distribution, and the diameters of particles were measured in accordance with the different pressure levels of power sprayer using 3 hole swath type nozzle, and the results are summerized as follows; 1. The distance of the most dense point from the nozzle was shortened by 0.5 meter with the 100-meter-long hose. The maximum reaching distances were reduced by 1.5 and 1.0 meters for the 13m/m and the 8.5 m/m hoses respectively, and the effective distance were reduced by 0.5 meter for both cases. 2. The effective distance can not be extended beyond 14 meters even if the length of hose is minimized at the rated pump pressure 28 kg/$cm^2$, it was 1 meter longer for 13m/m hose compared to the 8.5m/m one. 3. In case of 13m/m hose, the most dense point can be extended further by 0.5 meter increasing the pump pressure by 8 kg/$cm^2$, and the maximum distance and effective distance were increased by 2.0 and 0.5 meters respectively. There was no significant effect of pressure changes on the transportability in case of 8.5m/m hose. 4. Both the reduction of hose length and the increase of pump pressure influenced in large extent to the atomization effect of droplets. It was noticed that the diameter of droplet is related to the pump pressure and inside diameter of hose. 5. The pressure drop in 100-meter-long and l3m/m hose was 5~7kg/$cm^2$ at the pump pressure range of 25~33kg/$cm^2$, and it is an equivalent of 2% per 10 meter length of hose.

  • PDF

Study on Design and Application of an Inductive Coupler for Power Transmission Line (송전선용 비접촉식 커플러의 설계와 적용연구)

  • Kim, Hyun-Sik;Lee, Dong-Chul;Kim, Min-Ho;Lee, Gean;Oh, Young-Woo;Min, Byung-Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.3
    • /
    • pp.234-239
    • /
    • 2010
  • An inductive coupler, which feeds communication to the electric power transmission line, is required to establish Power Line Communication(PLC). The electro-magnetic property of magnetic core and design technology for coupler are very important to manufacture an inductive coupler for power transmission line. The magnetic core with superior electro-magnetic property was manufactured by using nanocrystalline alloy and an inductive coupler, which can operate at the maximum 2,000 A current, was designed and manufactured by establishment of current saturation, signal out winding, and electromagnetic simulation in this study. Communication speed of 14 Mbps in 600 meter communication distance of the real electric power transmission line was obtained by using the inductive coupler and application possibility of the inductive coupler for the electric power transmission line was certified.

Introducing the Latest 3GPP Specifications and their Potential for Future AMI Applications

  • Koumadi, Koudjo M.;Park, Byong-seok;Myoung, Nogil
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.245-251
    • /
    • 2016
  • Despite the exponential throughput improvement in mobile communications systems, their ability to satisfy requirements of state-of-the-art and future applications of advanced metering infrastructure (AMI) is still under investigation. Challenges are mainly due to the inadequacy of third generation partnership project (3GPP) networks to support large amounts of devices simultaneously, while the number of AMI end-devices and the frequency of their data transmission increase with new AMI-based applications. In this introductory survey, innovative and future AMI applications and their communication requirements are first reviewed. Then, we identify challenges of 3GPP long term evolution (LTE) in enabling future AMI applications. More importantly, the latest improvements to LTE-A standard release 12 and 13 are reviewed and analyzed with regards to their potential to improve the quality of LTE-enabled AMI. It is found that 3GPP enhancements on machine type communications (MTC) standards will significantly enhance AMI communications. Beyond MTC specifications, non-MTC-specific enhancements such as carrier aggregation and multi-connectivity for user equipment will also contribute greatly to improving reliability and availability of AMI devices. The paper's focus is towards improved backhaul support for innovative and future AMI applications, beyond traditional automatic meter reading.

The Implementation of Remote Meter Reading System Using Bluetooth Technology & SkT3 Protocol in CDMA (블루투스와 CDMA의 SMS프로토콜을 이용한 원격 가스 검침 시스템의 구현)

  • 김종현;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.443-446
    • /
    • 2003
  • This paper implement Remote Meter Reading System which is used Bluetooth and SMS in CDMA. This System propose system which tan detect a total amount of gas, electricity or water without a meterman, at home BlueTooth is a close range wireless communication technology which uses a wireless frequency 2.4GHz and has a high trust and self error correction technology according to a low power consumption quality and a high-speed frequency hopping. This makes get a high trust concerning a data transmission than an existing modem. In addition, though wireless modem is restricted by a minimal of a wireless terminal, it will be possible to coincide with the function of the portable with the low power consumption quality by using Bluetooth. And as the system on a chip of module progresses, the possibility of the small size is present. Nowadays, SMS Protocol in CDMA for have a network function based on PPP in CDMA Phone. The proposed Remote Meter Reading System to get more nobility, efficiency, and have good function. SMS Protocol in CDMA have profits which is low power, low cost, and low microwave output.

  • PDF

Design and Implementation of Multi-functional Java Card for AMR (원격검침을 위한 다기능 자바카드 설계 및 구현)

  • Kang, Hwan-Soo;Cho, Jin-Hyung;Kwon, Kwi-Seok;Lee, Jong-Man;Kang, Hwan-Il
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.8
    • /
    • pp.64-72
    • /
    • 2009
  • AMR(Automatic Meter Reading), which means that it reads the meter of electricity, gas, or water, etc at a remote place automatically through wired or wireless communication, has been studied in terms of Power Line Communication method and Local Area Wireless Communication method, etc. In this paper, we designed and implemented JCA(Java Card for AMR) capable of AMR, which is based on java Card technology indispensable to the ubiquitous world. In this paper, JCA follows standard transactional procedures offered by power supply company and manages power usage log and billing data, and is designed in order to satisfy EMV multi-functional specifications. Because JCA is a multi-functional smart card capable of post-issuance applets as an open platform, it is installed into other applications of affiliated concerns as well as credit card and traffic card applications. Not only the proposed JCA is a low cost system, compared to other AMR systems, but is capable of paying rates in advance or later by applying authentication and security function of java Card. In addition the proposed JCA system can create value added services such as affiliated services with corporate alliance.

Introduction to Industrial Applications of Low Power Design Methodologies

  • Kim, Hyung-Ock;Lee, Bong-Hyun;Choi, Jung-Yon;Won, Hyo-Sig;Choi, Kyu-Myung;Kim, Hyun-Woo;Lee, Seung-Chul;Hwang, Seung-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.4
    • /
    • pp.240-248
    • /
    • 2009
  • Moore's law has driven silicon technology scale down aggressively, and it results in significant increase of leakage current on nano-meter scale CMOS. Especially, in mobile devices, leakage current has been one of designers' main concerns, and thus many studies have introduced low power methodologies. However, there are few studies to minimize implementation cost in the mixed use of the methodologies to the best of our knowledge. In this paper, we introduce industrial applications of low power design methodologies for the decrease of leakage current. We focus on the design cost reduction of power gating and reverse body bias when used together. Also, we present voltage scale as an alternative to reverse body bias. To sustain gate leakage current, we discuss the adoption of high-$\kappa$ metal gate, which cuts gate leakage current by a factor of 10 in 32 nm CMOS technology. A 45 nm mobile SoC is shown as the case study of the mixed use of low power methodologies.

A Study on the Site Selection for Wind Power Using GIS (GIS를 이용한 풍력발전단지 최적입지 선정방법에 관한 연구)

  • Jeon, Sang-Hee;An, Seung-Man;Choi, Young-Jean;Sung, Hyo-Hyun
    • New & Renewable Energy
    • /
    • v.7 no.3
    • /
    • pp.83-91
    • /
    • 2011
  • The purpose of this study is to select appropriate location factors for wind power plant, provide detailed classification criteria, and find out appropriate sites for installing wind power plant in Gangwondo. In this study, the following 11 factors were extracted for site selection of wind power plant : wind resource, topography (valley angle, distance to the ridge), forest density, land use, preservation area, national park, Baekdu-Daegan, noise, shade, Transmission Line, and approaching roads. Each factor had relatively different level of importance so that AHP (Analytic Hierarchy Process) technique was used to calculated the weighted value per factor. For overlay analysis, classification criteria were prepared for each factor and each factor was classified into 3 grades : very appropriate, intermediate, poor. According to overlay analysis, the areas which received the highest grade (grade 5) was only in 0.16% of the total area of Gangwondo and had a tendency to exist along the mountain ridge over 600-meter elevation. Through analyzing the yearly average of wind power density, it was proved that the wind power density of areas with grade 4 or 5 had abundant wind resource over $400W/m^2$.

Development of a 3.5 mm Coaxial Microcalorimeter for Microwave Power Standards (3.5 mm 동축형 미소열량계 개발과 전자파전력 측정표준 확립)

  • Kwon, Jae-Yong;Kim, Jeong-Hwan;Kang, Tae-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.989-996
    • /
    • 2009
  • RF and microwave power is a basic quantity in electromagnetic metrology which linked directly to major electro-magnetic quantities such as attenuation, RF voltage, antenna characteristics and field strength. This paper deals with a power meter and power sensor with associated theory for RF and microwave power measurement. We study the theory and the key aspects in design of a 3.5 mm coaxial microcalorimeter which works from 50 MHz to 26.5 GHz as a primary microwave power standard.