• 제목/요약/키워드: Power meter

검색결과 530건 처리시간 0.031초

인공지능형 연삭가공 트러블 인식.처리 시스템 개발 (Development of Intelligent Trouble-Shooting System for Grinding Operation)

  • 하만경;곽재섭;박정욱;윤문철;구양
    • 동력기계공학회지
    • /
    • 제4권2호
    • /
    • pp.25-30
    • /
    • 2000
  • The grinding process is very complex and relates many parameters to control the process. As this reason, a theoretical analysis and a quantitative estimation of the grinding process has not been well established. In this study, the in-process monitoring system was suggested by applying the neural network for monitoring and shooting the malfunction of cylindrical plunge grinding process. This system used the power signals from the electric power meter. This neural network was composed of processing elements [4-(5-5)-3] with 4 identified power parameters. Because sensitivity is blunted some minute vibration components, the simulation result of this system has appeared about 10% erroneous recognition in the uncertain pattern and the average success rate of the trouble recognition was about 90%. Consequently, the developed system, which applied to the power signals, can be recognize enough to monitor the grinding process as in-process.

  • PDF

스마트 정보 모니터링 기술 (Smart Information Monitoring Technology)

  • 강만모;이동형;구자록
    • 한국인터넷방송통신학회논문지
    • /
    • 제10권6호
    • /
    • pp.225-233
    • /
    • 2010
  • 최근, 스마트 그리드, 스마트 홈 네트워크, 유비쿼터스 컴퓨팅 등의 분야에서 필요한 정보를 수집 및 가공하여 실시간 양방향으로 교환하고, 제어 및 감시하는 스마트 정보 모니터링 기술에 대한 연구를 계속 해 왔다. 본 논문에서는 에너지, U-Farm, 차량정보 및 홈 네트워크에 관한 스마트 정보 모니터링 기술의 응용 제품 및 최근 동향들을 알아본다. 특히, 스마트 그리드의 핵심부분인 스마트 미터와 실시간으로 정보를 교환하는 구글 파워미터, 유비쿼터스 농업을 위한 실시간 모니터링 시스템, 차량상태 정보를 위한 실시간 모니터링 시스템, 저전력, 저가격의 ZigBee 기반 스마트 정보 모니터링 기술 응용 및 관련사례에 대하여 기술한다. 마지막으로 스마트그리드 제주 실증단지 구축현황에 대하여 기술한다.

3중관용 스페이서를 적용한 대구경 지중열교환기의 성능측정에 관한 연구 (An Experimental Study on the Thermal Performance Measurement of Large Diameter Borehole Heat Exchanger(LD-BHE) for Tripe-U Pipes Spacer Apply)

  • 이상훈;박종우;임경빈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.581-586
    • /
    • 2009
  • Knowledge of ground thermal properties is most important for the proper design of large scale BHE(borehole heat exchanger) systems. The type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for insitu determination of design data for large diameter BHE for triple-U spacer apply. The main purpose has been to determine insitu values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a circulation pump, a inline heater, temperature sensors, flow meter, power analysis meter and a data logger for recording the temperature, fluid flow data. A constant heat power is injected into the borehole through the tripl-U pipes system of test rig and the resulting temperature change in the borehole is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective insitu values of rock thermal conductivity and borehole thermal resistance of large diameter BHE for spacer apply.

  • PDF

A Study of Wheel Tread Spalling Problem of $DF_{21}$ Locomotive

  • Weihua, Ma;Shihui, Luo
    • International Journal of Railway
    • /
    • 제1권2호
    • /
    • pp.31-36
    • /
    • 2008
  • $DF_{21}$ diesel locomotive was designed to satisfy the requirement of Kunming Meter track and the 2Co self-guided radial bogie was used to suit the complex curve track. There are totally 12 locomotives was served on the track. The first two locomotives were devotion running on the track since April 2003, the wheel tread splling was occurred on the middle wheel set of the two locomotives after running nearly 150 thousands km on the track of the two locomotives at August 2004. The dynamic analysis was carried out to find the reason. The wheel set longitudinal vibration resonance phenomenon was existed on the locomotive dynamic performance, and this was caused by the too big longitudinal stiffness of the journal box bar on the middle wheel set. Wheel set longitudinal vibration resonance maybe an important reason of lead to wheel tread spalling. The corresponding mend methods were put forward from the point of view of wheel set longitudinal vibration resonance. All the wheel tread of the 12 locomotives on the middle wheel set were in good condition and not occurred the wheel tread spalling after the mend till December 2007 after 350 thousands km were finished. The mechanism of the wheel tread splling and corresponding mend method was discussed in detail in this paper.

  • PDF

시공간 전력부하분석모델 설계 및 구현 (Design and Implementation of Spatio-temporal Power Load Analysis Model)

  • 신진호;이봉재;송재주;이정일;김영일
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2006년도 춘계학술발표대회
    • /
    • pp.537-540
    • /
    • 2006
  • 실세계의 복잡하고 종합적인 정보를 빠르고 효율적으로 분석 처리할 수 있는 지리정보시스템(GIS : Geographic Information System)의 효용성이 인식되면서 전력산업에서도 전국의 시설물 관리를 위해 수치지리정보를 구축하였다. 한편, 약 10만호의 고압고객을 대상으로 15분 단위의 전력사용량을 무선통신망을 이용하여 자동원격검침(AMR: Automatic Meter Reading)하고 있다. 본 논문에서는 산재된 대용량의 AMR 시계열성 데이터와 공간성을 지니는 전력설비 데이터를 이용하여 시각적 수요분석 및 공간적 분포특성 부하분석을 할 수 있는 새로운 활용모델을 개발하고 그 결과를 제시하고자 한다.

  • PDF

발목, 무릎 근력과 균형의 상관관계 (The Correlations among the Balance the Knee and Ankle Muscle Power)

  • 정영준
    • 대한정형도수물리치료학회지
    • /
    • 제16권2호
    • /
    • pp.82-87
    • /
    • 2010
  • Purpose : This study was investigate The correlations between the Balance and the knee muscle power and the ankle muscle power. Methods : This studied selected 9cases of the healthy persons. Each measure of muscle power used Bio-dex pro-3. Balance measure was used balance-meter the ability to measure Ant-post, lateral, overall balance. Result : 1. Knee flexor and extensor causes ankles that plantar flexion strength and high correlation r= .745, r= .825 have, Ankle dorsi flexor strength and a bit of correlation r= .249, r= .221) have. 2. Ankle plantar flexor strength and overall balance and correlation was the r= .204, Ankle dorsi flexor strength and lat. balance and correlation was the r= .314. 3. Knee extensor strength and overall balance and correlation was the r=.212.

  • PDF

사건수목분석을 통한 수배전설비의 전기화재위험성 분석 (Risk Analysis of Electrical Fire for Electric Power Installations by Event Tree Analysis)

  • 박영호;김두현;김성철
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.16-21
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on 15 components of power installations: the DS/LBS, LA, MOF, CT, PT, A/V meter, VCB, OCR, COS, PF, Transformer, Condenser(C), Grounding, Cable and Connector. To achieve that, power installations work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew Initiation events (IE) and End states (ES). ETA is applied to the main functions of each component, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events. If the suggested IEs and ESs are applied on the basis of power installations event cases, it is expected to prevent the same kinds of accident and operate power installations safely.

전력회사 관점의 배전계통 경제형 PQM 시스템 구축방안 (A Study on the Economical PQMS of the Utility Distribution Power System)

  • 박용업;이건행
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1523-1529
    • /
    • 2010
  • This paper describes the distribution power system econimical PQMS(Power quality monitoring system) of Utility. Recently, the korea power quality standard has been established based on the IEC Std. By IEC Std., the power quality assessment point is measured in PCC(Point of common coupling). In this case, the utility has to construct PQM system in all customer PCC point and the PQ meter cost would be very high in order to acquire the suitable data. Also the distribution system would be encounter the communication overload problem due to the huge data. Accordingly the utilities could not apply to PQM system in the distribution power system by the cost and communication problem. In this paper, the proposed economical PQMS has the voltage and current signal reiteration function and FFT operation function is transferred the server. Also the voltage and current measurement channels are minimized by a classified substation construction.

마이크로 프로세서를 이용한 용접전력 측정에 관한 연구 (Microprocessor based welding power meter)

  • 노창주;박상길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제11권4호
    • /
    • pp.33-40
    • /
    • 1987
  • Arc power is consumed energy per unit time between welding electrodes. The relations between consumed energy and electrode distance, current, voltage are nonlinear characteristics. Therefore commercial A.C. wattmeter cannot be used for measurement of the arc power. Most of arc energy measuring systems are developed for relay contact arc measurement. Relaly arc requires integrated instantaneous power because relay arc finishes in a short instant. But most of welding powers are continually consumed powers, therefore instantaneous power must be continually indicated in the form of averagy value. The author propose a new measurement method of power in which the current and voltage of welding electrode is multiplied and the resultant signal is passed to low pass filter in order to remove higher order frequency components. After integrating, the signal is devided by the integral interval and the results are stored in a computer memory.

  • PDF

낙뢰침입에 의한 대지전위상승이 발전소 저압전원회로에 미치는 과전압 해석 (Transient Voltage Analysis of Low-Voltage Source Circuit inn Thermal Power Plant due to Grounding Potential Rise by Lightening)

  • 양병모;정재기;민병욱;이종석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1644-1646
    • /
    • 1998
  • High-Smokestacks have been the symbol of the thermal power plant. Those cause the thermal power plant to be damaged by lightening for reaching several hundreds meter. In this paper, we investigated the accident of low-voltage source circuit due to grounding potential rise by lightening via high-smokestack in practically driving power plant, described examination into the cause and the impulse analysis. We analysed the transient voltage by EMTP(ElectroMagnetic Transient Program) via modeling the grounding system of power plant. This theoretical results coincided with practical accidental state. Therefore, it was verified that we could apply the grounding system of power plant and substation with the distribution-circuit analysis(EMTP).

  • PDF