• Title/Summary/Keyword: Power meter

Search Result 527, Processing Time 0.034 seconds

An Experimental Study on the Thermal Performance Measurement of Standing Column Well type Borehole Heat Exchanger (스탠딩컬럼웰형(SCW) 지중열교환기의 열성능 측정에 관한 실험적 연구)

  • Lee, Sanghoon;Choe, Yongseok;An, Kunmuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.122.2-122.2
    • /
    • 2010
  • Knowledge of ground thermal properties is most important for the proper design of BHE(borehole heat exchanger) systems. The configure type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for in-situ determination of design data for Standing Column Well apply. The main purpose has been to determine in-situ values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a sub-circulation pump, a boiler, temperature sensors, flow meter and a data logger for recording the temperature and circulation fluid flow data. A constant heating power is injected into the SCW through the test rig and the resulting temperature change in the SCW is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective in-situ values of rock thermal conductivity and thermal resistance of SCW.

  • PDF

Error Check Algorithm in the Wireless Transmission of Digital Data by Water Level Measurement

  • Kim, Hie-Sik;Seol, Dae-Yeon;Kim, Young-Il;Nam, Chul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1666-1668
    • /
    • 2004
  • By wireless transmission data, there is high possibility to get distortion and lose by noise and barrier on wireless. If the data check damaged and lost at receiver, can't make it clear and can't judge whether this data is right or not. Therefore, by wireless transmission data need the data error check algorithm in order to decrease the data's distortion and lose and to monitoring the transmission data as real time. This study consists of RF station for wireless transmission, Water Level Meter station for water level measurement and Error check algorithm for error check of transmission data. This study is also that investigation and search for error check algorithm in order to wireless digital data transmission in condition of the least data's damage and lose. Designed transmitter and receiver with one - chip micro process to protect to swell the volume of circuit. Had designed RF transmitter - receiver station simply by means of ATMEL one - chip micro process in the systems. Used 10mW of the best RF power and 448MHz-449MHz on frequency band which can get permission to use by Frequency Law made by Korean government

  • PDF

Implementation of Single-Phase Energy Measurement IC (단상 에너지 측정용 IC 구현)

  • Lee, Youn-Sung;Seo, Hae-Moon;Kim, Dong Ku
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.12
    • /
    • pp.2503-2510
    • /
    • 2015
  • This paper presents a single-phase energy measurement IC to measure electric power quantities. The entire IC includes two programmable gain amplifiers (PGAs), two ${\sum}{\Delta}$ modulators, a reference circuit, a low-dropout (LDO) regulator, a temperature sensor, a filter unit, a computation engine, a calibration control unit, registers, and an external interface block. The proposed energy measurement IC is fabricated with $0.18-{\mu}m$ CMOS technology and housed in a 32-pin quad-flat no-leads (QFN) package. It operates at a clock speed of 4,096 kHz and consumes 10 mW in 3.3 V supply.

Volume Resistivity Characteristics of Epoxy Resin using Nanocomposites (나노 컴퍼지트 에폭시 절연재료의 체적 고유저항 특성)

  • Choi, Hyun-Min;Kim, Joung-Sik;Kim, Won-Jong;Park, Young-Ha;Kim, Gwi-Yeol;Shin, Jong-Yeol;Lee, Jong-Yong;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.387-387
    • /
    • 2009
  • In the study the volume resistivity Characteristics of epoxy resin using nanocomposites, nano-comosites are made from insulating material epoxy resin using for power transformer equipment and molding several devices as changing amount of addition of diameter 12 [nm] $SiO_2$, we measured volume resistivity of nano-composites by High Resistance Meter(4329A). As the result of measurement, we have seen the epoxy resin using 1.6 [wt%] nanocomposites was the highest measured at the volume resistivity, and using 0.4 [wt%] nanocomposites was highest stabilized than others according to variable temperature properties.

  • PDF

Photosphere and Chromosphere observation of Pores

  • Cho, Kyung-Suk;Bong, Su-Chan;Lim, Eun-Kyung;Cho, Il-Hyun;Kim, Yeon-Han;Park, Young-Deuk;Yang, Heesu;Park, Hyung-Min;Chae, Jongchul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.88.1-88.1
    • /
    • 2013
  • We have investigated vertical motions of plasma in the pores and changes of the motions with height by using high time and spatial resolutions data obtained by the Fast Imaging Solar Spectrograph (FISS) of the 1.6 meter New Solar Telescope (NST). We infer the LOS velocity by applying the bisector method to the wings of CaII 854.2 nm line profile. We find that (1) upflow velocity in the pores decreases with height and turns into downward in the upper chromosphere; (2) 3 min and 5 min oscillations are found from the Doppler velocity in the pore at various wavelengths from the wing (${\pm}2.35{\AA}$) to the core (${\pm}1.25{\AA}$) of the CaII line; and (3) power of high (low) frequency oscillation obtained from the CaII intensity increases (decreases) with height. We discuss the physical implications of our results in view of the connection of LOS plasma flows in a concentrated magnetic flux (pore) between the photosphere and the low chromosphere.

  • PDF

Calibration of Frequency Response for a Sampling Oscilloscope (샘플링 오실로스코프의 주파수 응답특성 교정)

  • Cho, Chihyun;Lee, Dong-Joon;Lee, Joo-Gwang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.5
    • /
    • pp.344-352
    • /
    • 2018
  • We herein propose a calibration method for a sampling oscilloscope. The proposed method can correct the systematic errors in the oscilloscope such as time-based distortion and impedance mismatch. In addition, it can accurately estimate the residual jitter that remains after a time-based correction and the scale factor that varies in accordance with the setting of the pulse generator. The proposed method is validated thorough the comparison and verification with the power meter, and the uncertainty of the measurement method is analyzed.

Analysis of Properties of UV Corona on Insulator in Salt Water Environments (염수 환경 열화 상태를 모의한 절연애자의 자외선 코로나 특성 분석)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok;Lee, Myeong-Jun;Lee, Woo-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1590-1591
    • /
    • 2011
  • In this paper, the UV corona camera was developed using the solar blind and Multi Channel Plate(MCP) technology for the target localization of UV camera. UV camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The UV camera was developed and measured using a UV image, as applied voltage increased ultraviolet images of the phenomenon could be obtained. And we investigated properties of UV corona image on insulator in salt water environments. From the results, the breakdown voltage was decreased and UV images were taken at low voltages and the UV image is rapidly increased with increasing High voltage.

  • PDF

A Study on Improvement Method for Statistical Process and Quality of Electric Demand Load Profile (실시간 전력 검침 정보의 시계열정보 통계처리 성능 및 데이터 품질 향상 방안 설계)

  • Ko, Jong-Min;Yang, Il-Kwon;Jung, Nam-Jun;Jin, Sung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2080-2085
    • /
    • 2008
  • KEPCO's AMR (Automatic Meter Reading) is a system that performs the real-time inspection and management of the 15-minute load profile of electric power consumption through a wired and/or wireless network such as CDMA. It has been utilized widely for real-time collection and data analysis. So far, KEPCO has focused on establishing wireless networks using CDMA and collecting data in real time but failed to consider sufficiently performances that can improve the quality of the original data required in terms of data utilization as well as establish the summary information. In this paper, we are going to show the functions that improve data quality by recording the final renewal time of any erroneous data and maintaining such data lists to use them in the rebuilding of summary information. The goals are to reduce any load applied mainly on the DBMS (Database Management System) of AMR, to enable the real-time performance of establishment in the summary information, and to obtain high-quality inspection data. The performance evaluation result has revealed a 10-fold improvement compared to the traditional disk-based DBMS system when the summary information is established.

The Chemical Composition of V1719 Cyg: δ Scuti Type Star without the Accretion of Interstellar Matter

  • Yushchenko, Alexander V.;Kim, Chulhee;Jeong, Yeuncheol;Doikov, Dmytry N.;Yushchenko, Volodymyr A.;Khrapatyi, Sergii V.;Demessinova, Aizat
    • Journal of Astronomy and Space Sciences
    • /
    • v.37 no.3
    • /
    • pp.157-163
    • /
    • 2020
  • High resolution spectroscopic observation of V1719 Cyg were made at 1.8 meter telescope of Bohyunsan Optical Astronomy observatory in Korea. Spectral resolving power was R=45,000, signal to noise ratio S/N>100. The abundances of 28 chemical elements from carbon to dysprosium were found with the spectrum synthesis method. The abundances of oxygen, titanium, vanadium and elements with Z>30 are overabundant by 0.2-0.9 dex with respect to the solar values. Correlations of derived abundances with condensation temperatures and second ionization potentials of these elements are discussed. The possible influence of accretion from interstellar environment is not so strong as for ρ Pup and other stars with similar temperatures. The signs of accretion are absent. The comparison of chemical composition with solar system r- & s-process abundance patterns shows the enhancement of the photosphere by s-process elements.

Development of UV-IR Camera using IR Module and Improved UV Filter Transmittance (투과율 향상 UV 필터와 IR 모듈을 이용한 자외선-적외선(UV-IR) 카메라 개발)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Choi, Myeong-Il;Kim, Woo-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.37-43
    • /
    • 2012
  • UV-IR diagnostic technology is being used for predictive maintenance of high voltage equipment together with IR-thermography and ultrasonic devices. In this paper, the UV-IR camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. UV-IR camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. In a distance of 5m with the UV-IR it is possible to detect partial discharge with a PD level of 2.5 pC and a RIV(Radio Influence Voltage) level of $3.6dB{\mu}V$.