• Title/Summary/Keyword: Power management device

Search Result 354, Processing Time 0.028 seconds

Systematic Development of Mobile IoT Device Power Management: Feature-based Variability Modeling and Asset Development (모바일 IoT 디바이스 파워 관리의 체계적인 개발 방법: 휘처 기반 가변성 모델링 및 자산 개발)

  • Lee, Hyesun;Lee, Kang Bok;Bang, Hyo-Chan
    • Journal of KIISE
    • /
    • v.43 no.4
    • /
    • pp.460-469
    • /
    • 2016
  • Internet of Things (IoT) is an environment where various devices are connected to each other via a wired/wireless network and where the devices gather, process, exchange, and share information. Some of the most important types of IoT devices are mobile IoT devices such as smartphones. These devices provide various high-performance services to users but cannot be supplied with power all the time; therefore, power management appropriate to a given IoT environment is necessary. Power management of mobile IoT devices involves complex relationships between various entities such as application processors (APs), HW modules inside/outside AP, Operating System (OS), platforms, and applications; a method is therefore needed to systematically analyze and manage these relationships. In addition, variabilities related to power management such as various policies, operational environments, and algorithms need to be analyzed and applied to power management development. In this paper, engineering principles and a method based on them are presented in order to address these challenges and support systematic development of IoT device power management. Power management of connected helmet systems was used to validate the feasibility of the proposed method.

Design of Autonomous Independent Power System for USN Sensor Node Using Power CT (Power CT를 이용한 USN 센서노드용 자율독립전원 시스템 설계)

  • Son, Won-Kuk;Jeong, Jae-Kee
    • The Journal of Korean Institute of Information Technology
    • /
    • v.16 no.12
    • /
    • pp.101-107
    • /
    • 2018
  • In wireless sensor network technology, which has been applied to various fields, the power supply and the power management of sensors are the most important issues. For this reason, a new concept of power supply and power management device is required. In this paper, we developed an autonomous independent power supply system that supplies the stable power to a sensor node without an additional external input by applying the energy harvesting technology using the electromagnetic induction principle by utilizing the current flowing in the transmission line. The proposed autonomous independent power supply system consists of a power supply using Power CT and a power management system including a charging circuit. The power management device uses a voltage limiter circuit and a monitoring circuit of charging voltage and current to ensure the safety of charging of the battery. In order to verify the performance of the proposed system, we applied it to the SVL diagnostic system and confirmed that it operates stably.

Effect of Groove and Channel Size on the Thermal Transport Capacity of Micro-Capillary Pumped Loop for Mobile Electronic Device Cooling System (모바일 전자장비 냉각용 Micro-CPL내 형상크기변화에 따른 열성능 해석)

  • Kim, Byeong-Gi;Seo, Jeong-Se;Hwang, Geon;Mun, Seok-Hwan;Bae, Chan-Hyo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.329-334
    • /
    • 2005
  • As more high power wide band gap devices are being utilized. the thermal management issues associated with these devices need to be resolved. High power small devices dissipate excessive heat that must be cooled, but traditional cooling methods are insufficient to provide such a cooling means. This paper will evaluate a micro-capillary pumped loop thermal management system that is incorporated into the shim of the device, taking advantage of phase-change to increase the thermal conductivity of the system. The results of the modeling of the thermal management system will be discussed.

  • PDF

Development of Operational Technology and Integrated Measurement Information Management System for the Radioactivity Measurement Device (방사능 측정장치 운영 기술 및 측정정보 통합관리 시스템 개발)

  • Dong-Sik Jin;Kyeong-Ryeong Kim;Jae-Geun Lee
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.183-195
    • /
    • 2024
  • Additional functional upgrades to the large-area compton camera (LACC) measurement device that can provide characteristics evaluation information (nuclear species and radioactivity) and two-dimensional or three-dimensional distribution imaging information of radioactive materials existing in surface or internal of concrete structures are required in terms of work stability and efficiency in order to apply to actual decommissioning sites such as nuclear power plants or medical cyclotron facilities by using this measurement device. To this purpose, the technology that allows radiation workers to intuitively and visually check the distribution of radioactive materials in advance by matching the two-dimensional distribution imaging information of radioactive materials obtained through the LACC measurement device and visual imaging of the measurement zone (10 m × 5 m) was developed. In addition, the separate system that can automatically adjust the position (height) in units of the measurement area size (0.7 m × 0.3 m × 0.8 m) of the LACC measurement device was developed and the integrated management system for characteristics evaluation information and two-dimensional or three-dimensional distribution imaging information obtained per unit of measurement for radioactive materials was developed. These functional upgrades related to LACC measurement device can improve work efficiency and safety when measuring radioactivity of concrete structures and enable the establishment of appropriate decommissioning strategies using radioactivity measurement information for decommissioning nuclear power plants or medical cyclotron facilities.

Software Engineering Principles for the Development of Power-Efficient Mobile IoT Devices (파워 효율이 높은 모바일 IoT 단말 개발을 위한 소프트웨어 공학 원칙)

  • Lee, Hyesun;Lee, Kang Bok;Bang, Hyo-Chan
    • KIISE Transactions on Computing Practices
    • /
    • v.21 no.12
    • /
    • pp.762-767
    • /
    • 2015
  • An Internet of Things (IoT) is a system where various "things" are connected to each other via a wired/wireless network, and where information is gathered, processed, and interchanged/shared. One of the important actors in IoT is a mobile IoT device (such as a smartphone or tablet). These devices tend to consume a large amount of power in order to provide various high performance application services; however, as the devices cannot be supplied with power all the time, efficient power management is necessary. Power management of mobile IoT devices involves complex relationships between various entities such as application processors (APs), HW modules inside/outside AP, operating systems, mobile IoT platforms, and applications. In order to develop power-efficient mobile IoT devices, a method is needed to systematically analyze these relationships and manage power based on a clear understanding of them. To address this problem, software engineering principles for the development of power-efficient mobile IoT devices are presented in this paper. The feasibility of the proposed principles have been validated in the domain of smartphone camera power management.

Design and Implementation of eRTOS Real-time Operating Systems for Wearable Computers (웨어러블 컴퓨터를 위한 저전력 실시간 운영체제 eRTOS 설계 및 구현)

  • Cho, Moon-Haeng;Choi, Chan-Woo;Lee, Cheol-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.9
    • /
    • pp.42-54
    • /
    • 2008
  • In recent years, embedded systems have been expanding their application domains from traditional embedded systems such as military weapons, robots, satellites and digital convergence systems such as celluar phones, PMP(Portable Multimedia Player), PDAs(Personal Digital Assistants) to Next Generation Personal Computers(NGPCs) such as eating PCs, wearable computers. The NGPCs are network-based, human-centric digital information devices diverged from the traditional PCs used mainly for document writing, internet searching and database management. Wearable computers with battery capacity and memory size limitations have to use real-time operating systems with small footprints and low power management techniques to provide user's QoS in spite of hardware constraints. In this paper, we have designed and implemented a low-power RTOS (called eRTOS) for wearable computers. The implemented eRTOS has 18KB footprints and the dynamic power management and the device power management schemes are adapted in it. Experimental results with wearable computer applications show that the low power techniques could save energy up to 47 %.

A Study on Flicker Management Standard for Distribution Power System in Korea based on IEC 61000-3-7 (IEC 기반의 배전계통 플리커 관리기준 연구)

  • Kang, Moon-Ho;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1663-1667
    • /
    • 2011
  • Voltage variation caused by large loads such as arc furnace and large motors, which use the large and instantaneous currents, can cause the voltage flicker. The flicker irritates the human's eyes and also has an adverse effect on protection device, rotating machine and electronic device etc, therefore the flicker needs to be managed effectively. Recently, the Korea power quality standard has been established on the IEC standards. This paper presents the flicker management standard for distribution power system and suggests the flicker transfer coefficients for Korea power system based on the IEC 61000-3-7.

An efficient circuit design algorithm considering constraint (제한조건을 고려한 효율적 회로 설계 알고리즘)

  • Kim, Jae Jin
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.8 no.1
    • /
    • pp.41-46
    • /
    • 2012
  • In this paper, An efficient circuit design algorithm considering constraint is proposed. The proposed algorithm sets up in time constraint and area constraint, power consumption constraint for a circuit implementation. First, scheduling process for time constraint. Select the FU(Function Unit) which is satisfied with time constraint among the high level synthesis results. Analyze area and power consumption of selected FUs. Constraint set for area and power constraint. Device selection to see to setting condition. Optimization circuit implementation in selected device. The proposed algorithm compared with [7] and [8] algorithm. Therefore the proposed algorithm is proved an efficient algorithm for optimization circuit implementation.

Smart Power Management Using RTOS-based Uninterruptable Generator Supply

  • Lee, Chulju;Kang, Kyungtae;Noh, Dong Kun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.6
    • /
    • pp.1-7
    • /
    • 2016
  • An uninterruptible power supply (UPS) allows small companies and domestic users to cope with power outages; but existing designs lack flexibility of control and require expensive battery maintenance, with a cost proportional to the outage compensation time. We combine a compact synchronous generator with a battery, with 10% of the capacity that would otherwise be required, to obtain a UPS with reduced maintenance costs for the same performance. Any UPS must respond immediately to a power loss, and our uninterruptible generator supply (UGS) is therefore built around real-time scheduling of its internal operations; this also makes it suitable for integration into the industrial gateway. The UGS is based on a real-time operating system, with an integrated wireless module providing connectivity to a web server, for monitoring and management, which can be performed remotely on a mobile device.

Valve monitoring system design and implementation using an infrared sensor and ZigBee (Zigbee와 적외선 센서를 활용한 밸브 개폐 모니터링 시스템 설계 및 구현)

  • Sim, Hyun;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.1
    • /
    • pp.73-80
    • /
    • 2015
  • The valve device is installed in hazardous areas, such as a chemical plant explosion has been sealed with fire protection device to prevent the risk of explosion. In this paper, due to the explosion-proof devices using external power the device can not be used in infrared sensors and Zigbee sensor valve device by measuring the open degree of valve opening and closing of the danger zone to check whether. Valve opening and closing operation log screen time, we propose a low-power operation monitoring system administrators to manage and control the plant. Develop power control relay board apply an improved algorithm to apply the asynchronous LPL power management. The plant monitoring system and explosion-proof valve opening and closing the valve system with the intelligent device designed and implemented and tested it.