• 제목/요약/키워드: Power loss reduction

검색결과 436건 처리시간 0.023초

Analysis and Optimization of Passive intermodulation in Microwave Coaxial Cavity Filters

  • Cho, In-Kui;Kim, Jin-Tae;Jeong, Myung-Yung;Choy, Tae-Goo;Kang, Young-Il
    • ETRI Journal
    • /
    • 제25권2호
    • /
    • pp.133-139
    • /
    • 2003
  • We studied how the passive intermodulation (PIM) power arising in air cavity filters could be calculated and how the design of the filter could be optimized in order to reduce the amplitude of the PIM signal. To do this, using simulated results, we optimized the various parameters of a filter. PIM in an air cavity filter depends on the power dissipated in its cavities. A reduction of this power loss therefore decreases the PIM power in the air cavity filter. Our experimental results confirm that it is possible to design and produce air cavity filters that generate low PIM signals.

  • PDF

QPSK 복조기를 위한 반송파 복구 회로 설계 (Design of Carrier Recovery Loop for QPSK Demodulator)

  • 하창우;김형균;김환용
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(1)
    • /
    • pp.85-88
    • /
    • 2000
  • In order to resolve problems according to the phase error in QPSK demodulator of the digital communication systems. The demodulator requires carrier recovery loop which searches for the frequency and phase of the carrier. In this paper the complexity of implementation is reduced by the reduction into half of the number of the multiplier in filter structure of the conventional carrier recovery loop, and as the drawback of NCO of the conventional carrier recovery loop wastes a amount of power for the structure of lookup table , We designed the structure of combinational logic without the lookup table. In the comparison with dynamic power of the proposed NCO, the power of NCO with the lookup table is 175㎼, NCO with the proposed structure is 24.65㎼. As the result, it is recognized that about one eight of loss power is reduced. In the simulation of carrier recovery loop designed QPSK demodulator, it is known that the carrier phase is compensated.

  • PDF

고속 전환특성을 가진 자동부하전환 개폐기의 구동메커니즘의 동적 해석 (Dynamic Analysis of Driving Mechanism for ALTS with High-Speed Transfer Characteristics)

  • 정원선;권병희;안길영;오일성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1530-1535
    • /
    • 2003
  • The automatic load transfer switch (ALTS) typically automatically transfers electrical loads from a normal electrical power source to an emergency electrical power source upon reduction or loss of normal power source voltage. It can also automatically re-transfer the load to the normal power source when the normal voltage has been restored within acceptable limits. The transfer operation of ALTS is accomplished by a spring-driven linkage mechanism. In this paper we build a dynamic model of driving mechanism for ALTS using ADAMS and checked the characteristics of the transfer operation. Finally we performed a detailed design of the driving mechanism through results of analysis and confirmed it to satisfy design requirements.

  • PDF

PDP를 위한 새로운 전류원 타입의 에너지 회수 및 방전유지 회로 (A Novel Current-fed Energy Recovery Sustaining Driver for Plasma Display Panel (PDP))

  • 한상규;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.755-760
    • /
    • 2003
  • A novel current-fed energy-recovery sustaining driver (CFERSD) for a PDP is proposed in this paper. Its main idea is to recover the energy stored in the PDP or to inject the input source energy to the PDP by using the current source built-up in the energy recovery inductor. This method provides zero-voltage-switching (ZVS) of all main power switches, the reduction of EMI, and more improved operational voltage margins with the aid of the discharge current compensation. In addition, since the current flowing through the energy recovery inductor can compensate the plasma discharge current flowing through the conducting power switches, the current stress through all main power switches can be considerably reduced. Furthermore, it features a low conduction loss and fast transient time. Operations, features and design considerations are presented and verified experimentally on a 1020X106mm sized PDP, 50kHz-switching frequency, and sustaining voltage 140V based prototype.

  • PDF

고속 전철용 단상 PWM 컨버터의 고조파 저감에 관한 연구 (A Study on the Harmonic Reduction of the Single Phase PWM Converter for High Speed Rail)

  • 박정배;임훈규;이광운;여형기;유지윤
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.5-9
    • /
    • 1998
  • In the high speed rail system, the distortion of the voltage and the current waveform of the input power line increases the power loss and make a several electro-magnetic problems such as EMI or the interference of the communication line. In this paper, the control scheme of the PWM converter to make a good power factor and to regulated the output voltage as well as to reduce the harmonic component of the input current is proposed. Also a control schem of the PWM converter in the parallel operation to reduce the harmonics of the input current is proposed

  • PDF

Four-Switch 3상 Z-소스 능동전력필터 (Four Switch Three-Phase Z-Source Active Power Filter)

  • 수효동;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.224-225
    • /
    • 2013
  • This paper describes the four switch three-phase Z-source active power filter. This novel configuration has many advantages like reduction of cost, switching loss and smaller drive circuit. The paper presents an application of direct current control(DCC) method in a three-phase parallel Z-source active power filter to reduce the harmonics generated by the nonlinear load. The compensation principles and dynamics of the system are discussed in detail. The results show that the proposed control strategy is feasible and efficient.

  • PDF

위성방송용 QPSK 복조기를 위한 DPLL구조의 Carrier Recovery Loop 설계 (Design of Carrier Recovery Loop in DPLL Structure for QPSK Demodulator Satellite Broadcasting)

  • 하창우;이완범;김형균;김환용
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.165-168
    • /
    • 2001
  • In this W the complexity of implementation is reduced by the reduction into half of the number of the multiplier in filter structure of the conventional carrier recovery loop, and as the drawback of NCO of the conventional carrier recovery loop wastes a amount of power for the structure of lookup table, We designed the structure of combinational logic without the lookup table. In the comparison with dynamic power of the proposed NCO, the power of NCO with the lookup table is 175${\mu}$W, NCO with the proposed of structure is 24,65${\mu}$W. As if result, it is recognized that about one eight of loss power is reduced In the simulation of carrier recovery loop designed QPSK demodulator, it is known that the carrier phase is compensated.

  • PDF

Integrated DC-DC Converter Based Energy Recovery Sustainer Circuit for AC-PDP

  • Park, Jae-Sung;Shin, Yong-Saeng;Hong, Sung-Soo;Han, Sang-Kyoo;Roh, Chung-Wook
    • Journal of Power Electronics
    • /
    • 제12권6호
    • /
    • pp.878-885
    • /
    • 2012
  • A new sustainer with primary-side integration of DC/DC converters and energy recovery(SPIDER) circuits is proposed. The proposed circuit operates as a DC-DC converter during address period and energy recovery circuit during sustain period. Therefore, the conventional three electronic circuits composed of the power supply, X-driver, and Y-driver can be reduced to one circuit. As a result, it has desirable advantages such as a simple structure, less mass, fewer devices and cost reduction. Moreover, since the Zero Voltage Switching (ZVS) of all power switches can be guaranteed, a switching loss can be considerably decreased. To confirm the operation, validity, and features of the proposed circuit, experimental results from a prototype for 42-inch PDP are presented.

배전자동화시스템 적용을 위한 경제성 평가 (Economic Evaluation far the Application of the Distribution Automation System)

  • 홍순학;하복남;김호용;정경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.36-38
    • /
    • 1993
  • This study considers the economic aspect of the distribution automation system, which is the decision-making criteria of the electric utilities for the investment. The feeder automation candidate region is divided into two types of the urban and the rural. The total investment cost of the feeder automation for each type is estimated. The annual cost, is also estimated, by finding the fixed charge rate. To compare the annual cost and the economic effect cost, for the investment decision-making, the costs are quantitatively estimated on the following effects : the manpower replacement, the outage cost saving, the main transformer utilization improvement, the feeder utilization improvement, and the line loss reduction.

  • PDF

22.9kV 수용가 전력계통별 고조파 발생실태 및 관리기준 조사분석 (to examine of management standard by the harmonics measured and analyzed in 22.9kV Power lines)

  • 이은춘;신강욱;홍성택;홍영재;박영춘;임재일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.270-272
    • /
    • 2004
  • At the water supply field, high voltage induction motor is main facility of a load equipment. The motor is often out of order and its noise, generated heat, loss etc occurred occasionally. especially, transmission motor for flux control generates an amount of the harmonics then have a bad influence upon the electric power system. In this study, to analyze the total harmonics distortion of the water supply field receiving high voltage, the harmonics measured and analyzed using the PQA(Power quality Analyzer) according to the electric power system and electrical load and the reduction method presented.

  • PDF