• Title/Summary/Keyword: Power line modem network

Search Result 38, Processing Time 0.028 seconds

Development of Telemetering and Control system using PLC and Web (전력선통신과 인터넷을 이용한 원격제어 및 검침구현)

  • 최원호;박종연
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.4
    • /
    • pp.282-290
    • /
    • 2003
  • AMR(Automatic Meter Reading) and RC(Remote Control) System have been researched from former several decade for a various power rate system, a efficient power service and rising of personal expenses, etc. But the existing AMR and RC System have disadvantage which are complex and high cost to install an individual communication network of electricity company. This paper proposed a new type of AMR and RC System using PLC with Web. and made components for proposal system. Most customer who live in apartment have an internet cable in the Republic of Korea. Therefore there is no more installation component for communication in proposal system at the apartment, except Web server system and PLC modem. so we made the PLC modem the digital watt-hour meter with a build in PLC modem and the software on server computer for establishing the proposal system.

Impedance Measurement and Matching Technique for Medium-Voltage Powerline Communication (고압전력선 통신을 위한 임피던스 측정 및 정합 방안 연구)

  • 이재조;유정훈;홍충선;이대영
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.5
    • /
    • pp.345-352
    • /
    • 2004
  • Currently, high data rate PLC(Power Line Communications), up to 100 Mbps, which use frequency bandwidth between 2 MHz and 30 MHz is investigated very hard, and commercial PLC modem for low voltage powerline network (indoor) is coming soon into communication market. For the purpose of developing a fit communication system which has little distortion of signal and attenuation, it is surely necessary to know about channel environments of powerline. Especially, the impedance measurement of the powerline and impedance matching are very important. As is known, since medium-voltage powerline (22.9 ㎸) is still working, it is not so simple to measure the powerline impedance. In our study, a portable impedance measurement equipment is developed. It consists of coupling capacitor, a drain coil and impedance matching transformer. The equipment is easily connected to medium voltage line and impedance of power line is measured using a network analyzer. Also, measurement results are used for impedance matching of PLC signal. In fact, matching transformer with several different impedances are used. The matching transformer is connected between coupling capacitor and signal port. In this paper, the developed portable impedance measurement equipment and impedance measurement results are presented. Also impedance matching technique using matching transformers will be explained. We showed the result of the improved performance by the impedance matching.

Site Monitoring of Crews and Passengers on Board by the BLE and PLM Combination (BLE와 PLM 조합의 승선자 위치 모니터링)

  • Kwon, Hyuk-Joo;Yang, Hyun-Suk;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.463-467
    • /
    • 2015
  • When unforeseen accidents occur in a ship, it is important to save passengers safely and remove them from the accident area quickly. To solve such a situation, site information of passengers on board always must be identified. This paper implemented a site monitoring of crews and passengers based on the BLE and PLM combination, to prepare for unexpected accidents of the ships. This system was composed of BLE tag for crews, passengers and each room, PLM networks, data server, and monitoring PC. In this system, site information derived from the tag attached to the bodies and cabins of crews and passengers are transmitted through a power line network, and monitored on the screen of a monitoring PC. The proposed system guides them into the only authorized area considering the ship security and passengers' safety, and even has a special alarm call to warn them after entering an unauthorized area. This system enables the BLE-embedded tag battery to use for a long time because the BLE consumes low electric power, and can gain an economic advantage.

A Systematic Method of Probing Channel Characteristics of Home Power Line Communication Network for IP Based Control of Home Appliances (IP기반 가전 제어를 위한 전력선 통신망 채널 특성 추정기법에 관한 연구)

  • Ahn, Nam-Ho;Kim, Jung-Keun;Lee, Jae-Sik;Chang, Tae-Gyu;Kim, Hoon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.12
    • /
    • pp.696-701
    • /
    • 2003
  • This paper presents a systematic method of probing channel characteristics and communication reliabilities of home power line communication network applied to the Internet accessed control of home appliances. The effects of the three performance deterioating factors, i.e., additive noise, channel attenuation, and intersymbol interference, can be systematically measured by applying the channel probing waveform in the frequency range from 100KHz to 450KHz. Probability of bit error is derived with the probed channel parameters of the signal attenuation, noise and signal-to-interference ratio read in the frequency domain. The agreement between the derived probability of bit error and the measured probability of bit error supports the validity of the proposed approach of probing home power line channel characteristics. The experimental results performed with the constructed test-bed applying the proposed channel probing method also support the feasibility of commercially deploying the PLC modem installed home appliances and their services for the Internet accessed home automation.

Design and Properties of a Self Generation Equipment using Current Transformer (변류기를 이용한 자가발전 장치의 설계와 특성)

  • Byun, W.B.;Kim, H.S.;Kim, J.R.;Lee, H.Y.;Lee, J.H.;Ji, M.K.;Lee, J.;Oh, Y.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.427-428
    • /
    • 2008
  • We have studied design and application about an self generation equipment for underground power transmission cable. The split CT(Current Transformer), which has the applicable underground power transmission cable, was manufactured through electromagnetic simulation of magnetic core. And manufactured the AC-DC converter that supplied stable DC power for PLC modem when current of power line has more than 150A. An self generation equipment using the CT and AC-DC converter get into operation the PLC modem consistently. As a result, the underground power transmission cable was showed the application possibility through the stable communication and network characteristics.

  • PDF

Development of Demand Controller Using Power Line communication (전력선 통신을 이용한 디멘드 콘트롤러의 개발)

  • Kim Ho;Park Hae-Won;Lee Jeong-Bok;Seok Won-Yeop;Jeon Hee-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.619-622
    • /
    • 2001
  • In this paper, an intelligent demand control system was introduced. This system is composed of demand controller, RTU, Power Line Modem and HMI program. The developed demand controller was capable of synchronizing with watthour meter recommended by KEPCO. To control distant loads, network function using powerline communication is implemented in RTU, with HMI program, the untrained users are able to operate system easily. Additionally using the Powerline, the cost and time of installation is saved. The system performance was proved In a several experiments.

  • PDF

Measurement of Indoor Power Line Channel Characteristics Considering Capacitive Loads (용량성 부하를 고려한 옥내 전력선 채널 특성 측정)

  • Heo Yoon-Seok;Hong Bong-Hwa;Kim Chul;Jun Kye-Suk;Lee Dae-Young
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.6 s.336
    • /
    • pp.53-60
    • /
    • 2005
  • Considerable efforts has been recently devoted to the determination of accurate channel models for the power line environment, both for the indoor and outdoor cases. The common limitation of the known and previously published models is the particular type of approach followed. This paper is concerned with a power line channel characteristic measurement for the more fast and efficiently power line communication experiment. The need arises from the fact that indoor power cables consist of conductors and inductors. A capacitive load simulator is a essential equipment in the power line modem development for indoor power line network. We accomplished a channel data base by the frequency response method about the total 224 capacitor load cases. On the basis of this measurement modeling it is here revealed that the power line communication channel is a more deterministic media.

Design and Implementation of the Basic Technology for Solitary Senior Citizen's Lonely Death Monitor ing System using PLC

  • Huh, Jun-Ho;Seo, Kyungryong
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.6
    • /
    • pp.742-752
    • /
    • 2015
  • The communications through the power lines are called as the PLC and this is a common name for the communication modes for the information delivery. This technology transmits the data through the power lines on which the information is stored with the form of high frequency signal. The characteristic of the frequency signal is that the signal can be separated from the power line through exclusive power line modem and transmitted to the terminal devices. In this paper, 'In-home Headcount' checking algorithm using Wi-Fi and taking above mentioned advantages is proposed, and the basic Technology for such Solitary Senior Citizen's Lonely Death monitoring system has been designed and implemented. The comparative analysis has been conducted in this paper with the test-operated and test bed-completed 'Hyosimi 119 Safety-Welfare System' which is still being tested since 2008. With the 'In-home Headcount Checking Algorithm', Wi-Fi connection/disconnection status and SSIDs of relevant Wi-Fis will be checked. We expect that our proposed method will become as the basic Technology which can prevent lonely deaths of elderly people living alone. Since the PLC technology can be normally implement all the functions used on internet anticipate that the technology could be applied to many areas to construct a new form of communication network.

Implematation of AMR system using Power ine Communication

  • Park, Byoung-Seok;Hyun, Duck-Hwa;Jang, Mun-Jeong;Lim, Young-Hoon;Cho, Sung-U
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.119.4-119
    • /
    • 2001
  • It is the advantage of PLC that digitalization and networking of existing facility can be organized at low price because there is no need further construction of communication line considering that home appliance, information device and various kind of control devices are digitalized at low price. Moreover, AMR(Automatic Meter Reading) is very attractive to utility company because not only does it reduce the cost of reading meter, but also it can control and monitor the demand for energy. So, it can solve the consumers problem best and easily. It also can be easily realized that the utilities can expand there areas to values-added service through existing network. The performance of the PLC modem which is being developed now is not moven enough and much more test for outdoor modem is needed especially. Therefore, we, KEPRI, concentrate our efforts on configuring AMR system for test and investigation of the actual performance of various kinds ...

  • PDF

An Analysis of Characteristics of Underground Power line Communication Channel (지중 전력선 통신채널의 특성 해석)

  • Eom, Ki-Hwan;Shin, Jai-Ho;Lee, Seung-Joon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.5
    • /
    • pp.40-45
    • /
    • 2011
  • In this paper, to develop a broadband power line communication modem and network technologies, we analysis the characteristics of underground power line communication channel through actual tests. To measure the amount of attenuation by length and structure of broadband power line communication channel, we configure a measurement system of the channel with signal generator, spectrum analyzer and non-contacted coupler. For actual tests, we choose two of the longest lines among medium-voltage lines as a single line in the test lines and measure the characteristics of noise and signal attenuation level of the channel. The experimental results show that the channel has a impulse noise which can remarkably reduce communication capability. In the case of long lines, high-frequency attenuation appeared by length of the lines.