• 제목/요약/키워드: Power line

검색결과 6,051건 처리시간 0.034초

고속전력선통신과 무선통신간의 간섭 회피 방법에 대한 연구 (A Study on Methods of Interference Avoidance between Power Line Communications and Radio Communications)

  • 장동원;이영환
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.223-226
    • /
    • 2007
  • This paper first outlines the technology used in Power Line Communications(PLC) systems, and the political support being offered to the technology, from the point of view of its effect on electromagnetic compatibility (EMC). The radio spectrum needs protection from other interferers, and there is a regime in place to provide this interference avoidance/mitigation. Nevertheless, PLC has several features that mean that it is capable of creating such interference. These features are discussed, and some published field trial results are reviewed. Difficulties in achieving compatibility between the requirements for radio protection and the requirements for operation of the PLC system mean that there is no consensus as yet as to how PLC system components can be made compliant with EMC requirements. It is concluded that there is little prospect of an accommodation between the competing demands, so that if PLC is to become widespread it will be at the expense of the radio environment.

  • PDF

등가 전력선을 가진 Chua 회로에서의 카오스 동기화 (Chaos Synchronization using Chua Circuit with Equivalent Power Line)

  • 배영철
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.259-262
    • /
    • 2000
  • Chua's circuit is a simple electronic network which exhibits a variety of bihucation and attractors. The circuit consists of two capacitors, an inductor, a linear resistor, and a nonlinear resistor. In this paper, a transmitter and a receiver using two identical Chua's circuits are proposed anti synchronizations of a equivalent power line are investigated. Since the synchronization of the equivalent power line system is impossible by coupled synchronization, theory having both the drive-response and the coupled synchronization is proposed. Af a result, the chaos synchronization has delay characteristics in the equivalent power line transmission system caused by the line parameters L and C.

  • PDF

A Study of On-line Monitoring System for a KEPCO Pumped Storage Generator/Motor

  • Kim Hee-Dong;Ju Young-Ho;Kim Yong-Joo;Cho Kyu-Bock
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권2호
    • /
    • pp.90-95
    • /
    • 2006
  • An on-line diagnostic test has been studied and performed for the pumped storage generator/motor. This study aims at reducing the diagnostic cost, minimizing the technical dependency on third party manufactures. Further design of on-line diagnostic system such as shorted-turn of rotor winding, partial discharge (PD) of stator winding and air-gap between stator and rotor for pumped storage generator/motor has been verified. In addition, it needs to be validated on site performance of the developed continuous on-line monitoring system for corresponding tasks for the improvement of the availability & reliability during operation.

전력선통신 위해방지 기술기준의 개편 동향 (Reorganization trend on technical regulation of harm prevention for Power Line Communication)

  • 조평동;최문환;이상무
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.1071-1074
    • /
    • 2015
  • 전력선통신 위해방지 기술기준은 전력선통신 장치가 인체나 다른 설비에 위해를 주지 않도록 준수해야 할 기술적 사항을 규정하고 있다. 전력선통신 위해방지 기술기준은 내용면에서 선로설비 설치에 대한 기술기준과 통합 운영하는 것이 효율적이다. 본 논문에서는 국내 전력선통신의 기술적 배경과 기술기준 개편방향에 대해 같이 논하기로 한다.

  • PDF

22.9kV 배전선로 절연전선의 부식 검출 시스템 개발에 대한 연구 (A Study on the Development of Corrosion Detecting System for 22.9 kV Distribution Power Line Insulation Cable)

  • 김용준;오용철;이건영
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1410-1416
    • /
    • 2011
  • A corrosion detecting system for 22.9 kV distribution power line insulation cable, which can travel autonomously along the live line, is proposed. Eddy current test method is employed to detect the corrosion, and the system developed here is capable of detecting internal corrosion of a ACSR-OC. Somewhat details of the electrical and mechanical mechanism of the system and traveling algorithm are introduced. Experimental results applied to the sample cables having artificial corrosion and the operating distribution lines are provided. From the result, we confirmed that the system is useful for detecting internal corrosion of a ACSR, and is expected to be a new non-destructive testing equipment in the area of diagnosis for the distribution power line.

초전도 한류기를 주변압기 접지선에 설치시 배전계통의 순간전압품질 분석 (Voltage Quality Analysis in Power Distribution System with Superconducting Fault Current Limiter at Grounding Line)

  • 문종필
    • 전기학회논문지P
    • /
    • 제62권4호
    • /
    • pp.159-163
    • /
    • 2013
  • In this paper, voltage quality improvement is analyzed in case of Superconducting Fault Current Limiter (SFCL) installed in grounding line of main transformer in power distribution system. First, a resistive-type SFCL model is used. Next, Korean power distribution system is modeled. Finally, when SFCL is installed in the starting point of feeder and grounding line of main transformer, voltage qualities are evaluated according to various fault locations and resistance values of SFCL using PSCAD/EMTDC. The voltage quality results in case of grounding line are compared with the voltage in case of feeder.

Real-time line control system for automated robotic assembly line for multi-PCB models

  • Park, Jong-Oh;Hyun, Kwang-Ik;Um, Doo-Gan;Kim, Byoung-Doo;Cho, Sung-Jong;Park, In-Gyu;Kim, Young-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1915-1919
    • /
    • 1991
  • The efficiency of automated assembly line is increased by realizing the automation of each assembly cell, monitoring the line information and developing the real-time line control system it. which production flow is controllable. In this paper, the several modules which are important factors when constructing automated real-time control system, such as, line control S/W module, real-time model change module, error handling module and line production management S/W module, are developed. For developing these important programming modules, real-time control and multi-tasking techniques are integrated. In this paper, operating method of real-time line control in PCB automated assembly line is proposed and for effective control of production line by using multi-tasking technique, proper operating method for relating real-time line control with multi-tasking is proposed by defining the levels of signals and tasks. CIM-Oriented modular programming method considering expandability and flexibility will be added for further research in the future.

  • PDF

전력선 통신 시스템을 위한 머신러닝 기반의 원신호 예측 기법 (Machine Learning-Based Signal Prediction Method for Power Line Communication Systems)

  • 선영규;심이삭;홍승관;김진영
    • 한국위성정보통신학회논문지
    • /
    • 제12권3호
    • /
    • pp.74-79
    • /
    • 2017
  • 본 논문에서는 머신러닝 알고리즘 중 하나인 다층 퍼셉트론을 기반으로 전력선통신 시스템에서의 수신 신호를 이용하여 송신단에서 전송한 원신호를 예측하는 시스템 모델을 제안한다. 전력망을 활용한 통신 방식을 사용하는 전력선통신 시스템은 일반적인 통신설로를 활용하는 통신 방식에 비해 잡음이 많다. 이 때문에 전력선통신 시스템의 성능이 저하가 되는 문제가 발생한다. 이를 해결하기 위해 본 논문에서 제안하는 통신 시스템 모델을 이용하면 원신호 예측을 통해 잡음의 영향이 최소화되어 전력선통신 시스템의 성능저하를 완화시킨다. 본 논문에서는 제안한 통신 시스템 모델을 백색 잡음 환경에 적용하여 시뮬레이션을 해봄으로써 원신호가 예측 되는지를 입증한다.

mechanism of Equivalent Power Distribution in Parallel Connected ICP for Large Area Processing

  • 이진원;배인식;안상혁;장홍영;유신재
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.510-510
    • /
    • 2012
  • 반도체, 디스플레이, 태양광 등의 공정에서 사용되는 웨이퍼의 크기가 증가하고, 생산률이 플라즈마의 밀도에 비례한다는 연구 결과가 발표되면서 대면적 고밀도 플라즈마 소스 개발에 대한 연구가 활발히 진행되고 있다. 특히, ECR, ICP, Helicon plasma 등 고밀도 플라즈마 소스에 대한 관심이 높아지고 있다. 이에 따라, 여러 개의 ICP를 결합한 multiple ICP를 이용해 대면적 고밀도 플라즈마 소스 개발을 진행했다. Multiple ICP의 경우 각 ICP 소스에 같은 power (current)를 공급해야만 균일한 플라즈마 방전이 발생되어 균일도를 확보 할 수 있다. Current controller 같은 추가적인 장비를 설치하지 않고, power를 분배하는 transmission line을 coaxial 형태로 설계하고 같은 길이로 병렬 연결함으로써 각각의 ICP소스에서 균일한 플라즈마를 방전시킬 수 있었다. Power generator에서 보는 각 ICP의 total impedance는 각 ICP 소스의 impedance와 coaxial 형태의 transmission line의 characteristic impedance, frequency, 길이의 함수로 구할 수 있고, 이 total impedance가 일정하기 때문에 current가 균등하게 분배되어 각 ICP소스에 균등한 power 분배가 가능한 것이다. 실질적으로 ICP 소스의 impedance는 플라즈마 방전 유무에 따라 변화하기 때문에 일정하게 유지하는 것은 어렵다. Transmission line의 characteristic을 사용함으로써 ICP의 impedance의 변화에 상관없이 Total impedance를 일정하게 유지시킴으로써 균등한 power 분배가 가능하다는 것을 연구했다. Frequency는 13,56MHz, characteristic impedance를 $50{\Omega}$ (coaxial cable)으로 고정하고, ICP 소스의 플라즈마 방전 유무/antenna turn/소스 위치에 따른 total impedance를 transmission line의 길이에 따라 측정하고, 이를 이론값, 그래프와 비교하였다. 특정 length에서 플라즈마 방전 유무(ICP의 impedance 변화)와 상관없이 비교적 일정한 total impedance를 유지하는 것을 확인 했다. 이것은 특정 길이를 갖는 coaxial형태의 transmission line를 연결하면, total impedance는 플라즈마 방전 유무로 발생하는 ICP의 impedance 변화와 상관없이 일정하게 유지되어 각 ICP소스에 균등한 파워 분배가 가능하다는 것을 보여준 결과이다. 이것을 토대로 frequency에 따라(또는 characteristic impedance에 따라) 균등한 파워 분배가 가능한 coaxial 형태 transmission line의 특정 길이를 구할 수 있고, 대면적 소스에서 균등한 파워 분배를 위한 병렬연결에 적용할 수 있을 것이다.

  • PDF

전하 재활용과 전하 공유를 이용한 저전력 롬 (A Low Power ROM using Charge Recycling and Charge Sharing)

  • 양병도;김이섭
    • 대한전자공학회논문지SD
    • /
    • 제40권7호
    • /
    • pp.532-541
    • /
    • 2003
  • 메모리에서의 대부분의 전력은 프리디코더 라인, 워드 라인, 그리고 비트 라인 등과 같은 커패시턴스가 큰 라인들에서 소모된다. 이 라인들에서의 전력 소모를 줄이기 위하여 전하 재활용과 전하 공유를 사용한 세 가지 기법들이 제안되었다. 이 기법들은 전하 재활용 프리디코더(charge recycling predecoder, CRPD), 전하 재활용 워드 라인 디코더(charge recycling word line decoder, CRWD), 그리고 롬을 위한 전하 공유 비트 라인(charge sharing bit line, CSBL)이다. CRPD와 CRWD는 프리디코더 라인과 워드 라인의 전하를 재활용하여 소모 전력을 반으로 줄여주고, 전하 공유 기법을 사용하는 CSBL은 롬 비트라인의 스윙 전압을 낮춤으로써 소모 전력을 크게 줄여준다. CRPD, CRWD, 그리고 CSBL의 소모 전력은 기존의 82%, 72%, 그리고 64%이다. 제안된 세 가지 기법들을 사용하는 전하 재활용 전하 공유 롬(charge recycling and charge sharing ROM, CRCS-ROM)이 0.35㎛ CMOS공정으로 제작되었다. 제작된 8K×16비트 CRCS-ROM의 코어 크기는 0.51㎟이고 3.3V 전원과 100㎒ 동작 주파수에서 8.63㎽ 을 소모하였다.