• Title/Summary/Keyword: Power inverter

Search Result 3,965, Processing Time 0.036 seconds

Photovoltaic Power System using Discontinuous Mode Buck-Boost Chopper (불연속모드 승강압형 초퍼를 이용한 태양광발전시스템)

  • Kim, Young-Cheal;Suh, Ki-Young;Woo, Jung-In;Lee, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2115-2117
    • /
    • 1998
  • The output characteristics of solar cell are nonlinear, and these characteristics vary with load solar insolation. solar cell temperature. The PWM power inverter is realized by driving a inverter constructed with a high frequency buck-boost chopper in the discontinuous conduction mode(DCM). This paper present a buck-boost PWM inverter and its application for residential system.

  • PDF

Harmonic Waveforms Analysis and Efficiency Measurement of Inverter for driving Induction Motors (유도형 모터 구동용 인버터의 고조파 파형 분석과 효율 측정)

  • Jang, Seok-Myeong;Jeong, Sang-Sub;Park, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.282-284
    • /
    • 1997
  • The harmonics are injurious on the operation of the motor, electric instruments etc. In this paper, it is certified the capability of the electric measuring devices at the input/output of inverter. And it is measured the harmonics of the voltage and current waveforms. Also, this paper presents the efficiency of the inverter's power conversion by measuring the fundamental and total power at the input, DC bus and output.

  • PDF

Development of the down-scaled compensator for the solution of unbalanced load (부하불평형 해소를 위한 축소형 보상설비 개발)

  • Kim Joorak;Han Moonseob;Lee Changmu;Jung Hosung;Park Hyunjune;Kang Moonho;Kim Junghoon
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.649-654
    • /
    • 2005
  • This paper proposes analysis on new equipment for power quality in electric railway. The proposed equipment consists of series inverter and parallel inverter. Each inverter is connected by capacitor as dc link. This structure can be compensated for active and reactive power in catenary through transformer.

  • PDF

Analysis of voltage controller of Dual-Buck Inverter using Redox Flow Battery (RFB 용 Dual-Buck Inverter 전압제어 품질 향상에 관한 연구)

  • Choe, Jung-Muk;Cho, Younghoon;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.393-394
    • /
    • 2014
  • This paper proposes advanced RFB PCS for islanded environment. To accommodate islanded system, power conditioning needs voltage control authority changing. Dualbuck inverter topology is designed for the high efficiency. In order to reduce voltage error the repetitive controller is used in this paper. The control performance has been verified with computer simulation.

  • PDF

A Novel Photovoltaic Power Harvesting System Using a Transformerless H6 Single-Phase Inverter with Improved Grid Current Quality

  • Radhika, A.;Shunmugalatha, A.
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.654-665
    • /
    • 2016
  • The pumping of electric power from photovoltaic (PV) farms is normally carried out using transformers, which require heavy mounting structures and are thus costly, less efficient, and bulky. Therefore, transformerless schemes are developed for the injection of power into the grid. Compared with the H4 inverter topology, the H6 topology is a better choice for pumping PV power into the grid because of the reduced common mode current. This paper presents how the perturb and observe (P&O) algorithm for maximum power point tracking (MPPT) can be implemented in the H6 inverter topology along with the improved sinusoidal current injected to the grid at unity power factor with the average current mode control technique. On the basis of the P&O MPPT algorithm, a power reference for the present insolation level is first calculated. Maintaining this power reference and referring to the AC sine wave of bus bars, a sinusoidal current at unity power factor is injected to the grid. The proportional integral (PI) controller and fuzzy logic controller (FLC) are designed and implemented. The FLC outperforms the PI controller in terms of conversion efficiency and injected power quality. A simulation in the MATLAB/SIMULINK environment is carried out. An experimental prototype is built to validate the proposed idea. The dynamic and steady-state performances of the FLC controller are found to be better than those of the PI controller. The results are presented in this paper.

Active-clamp Class-E High Frequency Resonant Inverter with Single-st (단일 전력단으로 구성된 Active-clamp E급 고주파 공진 인버터)

  • Kang, Jin-Wook;Won, Jae-Sun;Kim, Dong-Hee;Ro, Chae-Gyun;Sim, Kwang-Yeal;Le, Bong-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1193-1195
    • /
    • 2002
  • This paper presents Active-clamp Class-E high frequency resonant inverter with single-stage. The proposed circuit is integrated Active-c class-E circuit to boost converter with the funct power factor correction. Boost converter is opera positive and negative half cycle respectively at frequency(60Hz), operating in Discontinuous Con Mode(DCM) of boost converter performs high p factor. By adding active-clamp circuit in Cl inverter, main switch of inverter part is operat only ZVS(Zero Voltage Switch), but also reduce switching voltage stress of main switch. Simulation result using Psim4.1 show that the p prove the validity of theoretical analysis. This proposed inverter will be able to be pract used as a power supply in various fields are ind heating applications, DC-DC converter etc.

  • PDF

An Improved SVPWM Control of Voltage Imbalance in Capacitors of a Single-Phase Multilevel Inverter

  • Ramirez, Fernando Arturo;Arjona, Marco A.
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1235-1243
    • /
    • 2015
  • This paper presents a modified Space Vector Pulse Width Modulation Technique (SVPWM), which solves the well-known problem of voltage imbalance in the capacitors of a single-phase multilevel inverter. The proposed solution is based on the measurement of DC voltage levels at each capacitor of the inverter DC bus. The measurements are then used to adjust the size of the active vectors within the SVPWM algorithm to keep the voltage waveform sinusoidal regardless of any voltage imbalance on the DC link capacitors. When a voltage deviation exceeds a predetermined hysteresis band, the correspondent voltage vector is restricted to restore the voltage level to an acceptable threshold. Hence, the need for external voltage regulators for the voltage capacitors is eliminated. The functionality of the proposed algorithm is successfully demonstrated through simulations and experiments on a grid tied application.

Grid Connected Inverter of ESS for Seamless mode Transition (분산 발전 시스템에서 계통연계 인버터의 매끄러운 모드 전환)

  • Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.4
    • /
    • pp.364-372
    • /
    • 2016
  • In this paper, a voltage controller for the seamless transition of a grid-connected inverter for ESS is proposed. The single-phase inverter is operated as a current controller when the grid is connected and as a voltage controller in the stand-alone mode when the grid is disconnected. Generally, in the case of grid recovery, the overcurrent may flow into the system because of the mismatch phase between the inverter output and grid voltages. The proposed controller resolves the overcurrent problem through phase delay problems with initial value feed-forward control of the integrator when the grid voltage is restored. The effects of the control method are simulated through PSIM, and the usefulness of the control method is verified through experiments.

A Study on Characteristics of input current controlled inverter arc welder (입력역률 제어형 인버터 용접기 특성해석에 관한 연구)

  • Song, S.H.;Woo, D.H.;Chae, Y.M.;Choe, G.H.;Jang, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.324-327
    • /
    • 1996
  • This paper presents the adoption of PWM converter to enhance input power factor in inverter arc welder. By using PWM converter in inverter arc welder, the disadvantages of bridge diode converter such as low input power factor is improved, new NCT(Noise Cut Transformer) is designed to reduce noise which has harmful effect in switching component, half bridge PWM inverter is adopted to reduce cost in inverter arc welder.

  • PDF

A Simple Undeland Snubber Circuit for Flying Capacitor 3-level Inverter

  • Kim In-Dong;Nho Eui-Cheol;Lee Min-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.281-285
    • /
    • 2001
  • This paper proposes a snubber circuit for flying capacitor multilevel inverter and converter. The proposed snubber circuit makes use of Undeland snubber as basic snubber unit. It has such an advantage of Undeland snubber used in the two-level inverter. Compared with conventional RLD/RCD snubber for multilevel inverter and converter, the proposed snubber keeps such good features as fewer number of components, reduction of voltage stress of main switching devices due to low overvoltage, and improved efficiency of system due to low snubber loss. In this paper. the proposed snubber is applied to three-level flying capacitor inverter and its feature is demonstrated by computer simulation and experimental result.

  • PDF