• 제목/요약/키워드: Power grid

검색결과 2,995건 처리시간 0.028초

2MVA급 배터리 에너지 저장시스템 개발 (A Development of 2MVA Battery Energy Storage System)

  • 김수홍;김태형;김윤현;인동석;권병기;최창호
    • 전력전자학회논문지
    • /
    • 제17권2호
    • /
    • pp.174-181
    • /
    • 2012
  • Energy storage system connected to the grid has two functions such as the surplus power of a grid is stored in batteries or the energy stored in batteries will supply to the grid when the grid needs. The battery energy storage system consist of power condition system (PCS) for power supply and battery conditioning system (BCS). Lithium-ion batteries are mainly used. In this paper, the battery energy storage system connected to the grid described. The configuration of the 2MVA class power control system using water cooling and battery system are presented. And control method for the system and the output filter design method are proposed. Experimental verification of the proposed system is provided with 2MVA PCS and 500kWh BCS.

Control Strategy Compensating for Unbalanced Grid Voltage Through Negative Sequence Current Injection in PMSG Wind Turbines

  • Kang, Jayoon;Park, Yonggyun;Suh, Yongsug;Jung, Byoungchang;Oh, Juhwan;Kim, Jeongjoong;Choi, Youngjoon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.244-245
    • /
    • 2013
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF

농형 유도발전기의 계통 연계시 전압 변동 및 전력 흐름 분석 (Analysis for Voltage Fluctuation and Power Flow at the Grid-Connected Time of Squirrel-Cage Induction Generator)

  • 김종겸
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.45-51
    • /
    • 2014
  • Synchronous generators and induction generators are mainly used in hydroelectric power generation. Synchronous generator is mainly applied to large hydroelectric plants but induction generator is applied to the small hydro power plants. Stability of induction generator is slightly less than the synchronous generator. However, induction generator has many advantages rather than a synchronous generator in terms of price and maintenance. So Induction generator is used primarily in small hydroelectric power station less than 1,000kW recently. Squirrel cage induction generator generates a high inrush current at the grid-connection. This high inrush current causes a voltage drop on the grid. In order to reduce the voltage drop and to analyze the power flow, the analysis for operating characteristics of the induction generator should be reviewed in advance. In this study, we analyzed the voltage drop and power flow analysis when a 1500kW induction generator is connected to the grid. The voltage drop is slightly higher than the acceptable range of distributed power supply voltage and the power flow of the generator is performed well.

New Control Strategy for Three-Phase Grid-Connected LCL Inverters without a Phase-Locked Loop

  • Zhou, Lin;Yang, Ming;Liu, Qiang;Guo, Ke
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.487-496
    • /
    • 2013
  • The three-phase synchronous reference frame phase-locked loop (SRF-PLL) is widely used for synchronization applications in power systems. In this paper, a new control strategy for three-phase grid-connected LCL inverters without a PLL is presented. According to the new strategy, a current reference can be generated by using the instantaneous power control scheme and the proposed positive-sequence voltage detector. Through theoretical analysis, it is indicated that a high-quality grid current can be produced by introducing the new control strategy. In addition, a kind of independent control for reactive power can be achieved under unbalanced and distorted grid conditions. Finally, the excellent performance of the proposed control strategy is validated by means of simulation and experimental results.

Modelling a Stand-Alone Inverter and Comparing the Power Quality of the National Grid with Off-Grid System

  • Algaddafi, Ali;Brown, Neil;Rupert, Gammon;Al-Shahrani, Jubran
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권1호
    • /
    • pp.35-42
    • /
    • 2016
  • Developments in power electronics have enabled the widespread application of Pulse Width Modulation (PWM) inverters, notably for connecting renewable systems to the grid. This study demonstrates that a high-quality power can be achieved using a stand-alone inverter, whereby the comparison between the power quality of the stand-alone inverter with battery storage (off-grid) and the power quality of the utility network is presented. Multi-loop control techniques for a single phase stand-alone inverter are used. A capacitor current control is used to give active damping and enhance the transient and steady state inverter performance. A capacitor current control is cheaper than the inductor current control, where a small current sensing resistor is used. The output voltage control is used to improve the system performance and also control the output voltage. The inner control loop uses a proportional gain current controller and the outer loop is implemented using internal model control proportional-integral-derivative to ensure stability. The optimal controls are achieved by using the Sisotool tool in MATLAB/Simulink. The outcome of the control scheme of the numerical model of the stand-alone inverter has a smooth and good dynamic performance, but also a strong robustness to load variations. The numerical model of the stand-alone inverter and its power quality are presented, and the power quality is shown to meet the IEEE 519-2014. Furthermore, the power quality of the off-grid system is measured experimentally and compared with the grid power, showing power quality of off-grid system to be better than that of the utility network.

Compensation of Unbalanced PCC Voltage in Off-shore Wind Farms of PMSG Type Turbine

  • Kang, Jayoon;Han, Daesu;Suh, Yongsug;Jung, Byoungchang;Kim, Jeongjoong;Park, Jonghyung;Choi, Youngjoon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.215-216
    • /
    • 2014
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF

PV용 계통연계형 인버터의 새로운 Topology 고찰 (Inquiry of New Topology for Grid-connected Photovoltaic Inverter)

  • 정영석;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.248-251
    • /
    • 1999
  • Recently, according to developing industry and life style, power consumption have been increased year after year. Currently these much power demand from power consumer is weakening the allowable power reverse margin in summer. As on of the remedies about this problem, the small scale grid-connected photovoltaic system is considered for auxiliary power source. Generally, grid-connected inverter have a isolation transformer for electrical isolation from utility. This paper propose transformerless system topology an inquiry the validity using simulation.

  • PDF

긴급제언 - 스마트 그리드 (Smart Grid)

  • 정춘병
    • 기술사
    • /
    • 제42권6호
    • /
    • pp.36-41
    • /
    • 2009
  • Smart Grid is grafting IT(information technology) techniques on existing electric power network, supplier and the consumer to do real-time exchange of information lead to both direction and energy efficiency optimization, it is a next potential electric power network method. Because of applying various distributed electric power sources, the electric power network system will follow in size and it is dispersive and it will operate independently, and it become the intelligent electric power network, which in consumer demand reacts at real-time, because of using various sensors. In this article explain concept, features, and contemporary background of Smart Grid, and describe improve reliability of the electric power quality.

  • PDF

Micro-Source의 계통 연계용 인덕터 크기 선정에 관한 연구 (A Study on Determining the Size of the Interface Inductor for Grid-Connected Micro-Sources)

  • 손광명;김영섭
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.52-58
    • /
    • 2005
  • Micro-Grid의 개념은 CERTS(Consortium for Electric Reliability Technology Solutions)에 의해 제안된 새로운 분산 전원 망으로서 부하에 열과 수 $[KW]{\sim}1[MW]$ 사이의 전력을 함께 제공하는 Micro-Source에 의해 구성되어 있다. Micro-Source는 친환경적인 연료전지나 마이크로터빈 등을 에너지원으로 사용하며, 전력품질 제어를 위해 전압형 인버터를 채용하고 독립적인 유무효전력 제어가 가능한 새로운 개념의 분산전원이다. Micro-Source가 효율적으로 유효전력 및 무효전력을 전력시스템에 공급하기 위해서는 계통연계용 인덕터가 필요한데, 본 논문에서는 인덕터의 제어 범위와 각 변수의 한계를 함께 고려하고 전달 및 제어하고자 히는 유효 및 무효 전력의 범위에 의해 인덕터 용량을 결정하는 절차를 제안하였다.

스마트 그리드를 위한 분산자원과 전력변환장치 기반 마이크로그리드 독립운전 (Microgrid Island Operation Based on Power Conditioning System with Distributed Energy Resources for Smart Grid)

  • 허세완;박완기;이일우
    • 한국통신학회논문지
    • /
    • 제42권5호
    • /
    • pp.1093-1101
    • /
    • 2017
  • 스마트 그리드를 구성하는 기본 단위 요소인 마이크로그리드(Microgrid)는 전력의 중앙 공급방식에서 벗어나 독립된 하나의 체계를 이룬다. 본 논문은 전력변환장치(Power Conditioning System)를 기반으로 마이크로그리드를 계통으로부터 전기적으로 독립시키고, 신재생 에너지원과 에너지 저장장치(Energy Storage System) 등의 분산자원(Distributed Energy Resource)을 활용하여 효과적으로 독립 상태를 유지하고 운영할 수 있는 방법을 제안한다. 계통의 위상검출과 동기화를 통해 계통에 연계하거나 독립 시에 부하에 미치는 영향을 최소화할 뿐만 아니라 계통의 정전 상황에서도 안정적으로 운영이 가능하다.