• Title/Summary/Keyword: Power fluctuation

Search Result 599, Processing Time 0.044 seconds

Simulation of the Wind Power Generation System with Energy Storage System (전기저장 장치가 포함된 풍력발전 시스템에 대한 시뮬레이션)

  • Oh, Si-Doek;Lim, Hee-Sue;Seo, Seok-Ho;Kim, Ki-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.303-306
    • /
    • 2008
  • The wind power generation systems have a fluctuating or intermittent power output due to the variability of the wind speed. The amount of wind generation which can be connected to the grid without causing voltage stability problems is limited. In this study, the simulation of the wind power generation including energy storage system were performed to reduce the fluctuation of wind power output and to obtain the optimal operation planning of energy storage system.

  • PDF

Development of an automatic steam generator level control logic at low power (저 출력시 증기발생기 수위의 자동제어논리 개발)

  • Han, Jae-Bok;Jung, Si-Chae;Yoo, Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.601-604
    • /
    • 1996
  • It is well known that steam generator water level control at low power operation has many difficulties in a PWR (pressurized water reactor) nuclear power plant. The reverse process responses known as shrink and swell effects make it difficult to control the steam generator water level at low power. A new automatic control logic to remove the reverse process responses is proposed in this paper. It is implemented in PLC (programmable logic controller) and evaluated by using test equipment in Korea Atomic Energy Research Institute. The simulation test shows that the performance requirements is met at low power (below 15%). The water level control by new control logic is stabilized within 1% fluctuation from setpoint, while the water level by YGN 3 and 4 control logic is unstable with the periodic fluctuation of 25% magnitude at 5% power.

  • PDF

Transport of SVS from Sudagu to Yangju and Study about harmonic wave, feature of control (서대구S/S SVC의 양주S/S 이설관련 고조파 및 제어특성 검토)

  • Jang, Suk-Han;Shin, Soon-Young;Choi, Man-Sik;Youn, Jong-Su
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.633-635
    • /
    • 2007
  • To cope with increasing power demand in metropolitan area, the power system in Korea has equipped with unit generator of large capacity, high density and uneven distribution, and transmission line of long distance, large capacity and high voltage. As the power system growing up enormous, it has become difficult to maintain the standard voltage in case of radical fluctuation of load or severe change of voltage by power system fault for its weakness of responsive characteristics although the power condenser has been installed to solve the unstability by lack of reactive power. Consequently, we review harmonic wave production and control characteristics to solve unstability problem of voltage in northern metropolitan, to reduce transmission restriction cost and to minimize load shedding by relocation of SVC (Static Var Compensator), which is highly effective for improvement of responsive characteristics for radical voltage fluctuation.

  • PDF

Adaptive Gain-based Stable Power Smoothing of a DFIG

  • Lee, Hyewon;Hwang, Min;Lee, Jinsik;Muljadi, Eduard;Jung, Hong-Ju;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2099-2105
    • /
    • 2017
  • In a power system that has a high wind penetration, the output power fluctuation of a large-scale wind turbine generator (WTG) caused by the varying wind speed increases the maximum frequency deviation, which is an important metric to assess the quality of electricity, because of the reduced system inertia. This paper proposes a stable power-smoothing scheme of a doubly-fed induction generator (DFIG) that can suppress the maximum frequency deviation, particularly for a power system with a high wind penetration. To do this, the proposed scheme employs an additional control loop relying on the system frequency deviation that operates in combination with the maximum power point tracking control loop. To improve the power-smoothing capability while guaranteeing the stable operation of a DFIG, the gain of the additional loop is modified with the rotor speed and frequency deviation. The gain is set to be high if the rotor speed and/or frequency deviation is large. The simulation results based on the IEEE 14-bus system demonstrate that the proposed scheme significantly lessens the output power fluctuation of a WTG under various scenarios by modifying the gain with the rotor speed and frequency deviation, and thereby it can regulate the frequency deviation within a narrow range.

Fluctuation Rates of Phytoplankton Assemblages by Passage through Power Plant Cooling System

  • Kang, Yeon-Shik;Lim, Ju-Hwan;Jeong, Yeon-Tae;Jeon, In-Sung
    • Korean Journal of Environmental Biology
    • /
    • v.30 no.3
    • /
    • pp.173-184
    • /
    • 2012
  • In order to investigate the fluctuation rates [FR] of phytoplankton after passage through a cooling system, the standing crops, chlorophyll a concentrations and carbon assimilation number of phytoplankton were surveyed at intake and outlet at Wolsong nuclear power plant [NPP] from July 2006 to June 2008. As a result, the total mean standing crops of phytoplankton were $1.0{\times}10^6\;cells\;L^{-1}$ and $7.3{\times}10^5\;cells\;L^{-1}$ at intake and outlet, respectively. The FR of phytoplankton by passage through the cooling system [PTCS] was 27.0%. Among them, the FR of microplankton and nanoplankton were 34.1% and 12.4%, respectively. In addition, the FR of diatoms and dinoflagellateswere 33.9% and 29.7%, respectively. These results showed the entrainment effects on microplankton and diatoms by PTCS were higher than those of nanoplankton and dinoflagellates. The FR of total chlorophyll a concentrations were 54.4%, and the FR of microplankton, nanoplankton and picoplankton were 58.9%, 38.5%, and 52.4%, respectively. So the entrainment effects on microplankton by PTCS were higher than those of nanoplankton and picoplankton. The mean FR of carbon assimilation number of phytoplankton was 57.6%, and the seasonal variations of FR of carbon assimilation number ranged from 47.5% to 76.8%. Our results indicated that the phytoplankton species responded differently to power plant operating conditions such as elevated temperature, chlorination, and mechanical impacts.

Experimental Verification for Transverse Vibration Behavior of a Spinning Disk with Torque Variation (구동토크의 고주파 변동 성분이 존재하는 회전원판의 횡진동 거동에 대한 실험 검증)

  • Lee Kee-Nyeong;Shin Eung-Soo;Kim Ock-Hyun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.4
    • /
    • pp.89-95
    • /
    • 2005
  • This paper intends to identify experimentally the relationship between transverse vibration behavior of a spinning disk and high-frequency fluctuation in the driving torque. A testrig has been developed using a CD-ROM disk, a driving motor with torque-varying capability and a power transmission belt and a laser vibrometer was employed to measure the transverse vibration displacements of the disk for a certain range of the spinning speed. The results show that the spinning speed and the magnitude and frequency of the torque fluctuation affect the stability of the disk. In other word, the torque fluctuation causes the instability of the disk at several ranges of the spinning speed below the critical speed and its effects become larger as the disk spins faster or the magnitude of torque fluctuation becomes bigger. The experimental results are found to be in good agreement with analytical estimation.

Analysis of Defluidization Using Pessure Fluctuation Properties in a Fuidized Bed Combustor (유동층연소로에서 압력요동특성치를 이용한 비유동화 상태 해석)

  • 장현태;유정근
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.2
    • /
    • pp.111-118
    • /
    • 1997
  • Granulation procedure was carried out in a 0.109m I. D., 1.8m height fluidized bed coal combustor of the multi-sized particles. The domestic anthracite with heating value 3240kcal/kg was used. Granulation of fine coal particles and fluidizing characteristics were investigated by the pressure fluctuation properties such as mean pressure, standard deviation of pressure fluctuation and power spectrum distribution. Defluidization state and granulation mechanism were also studied by the various analysis. It was found that the conversion efficiency in the elutriated stream was increased by the coalescence of fine coal particles. Defluidization and pressure fluctuation properties were interrelated and this result was indication of the capabilities of pressure fluctuation properties analysis in the diagnostics of fluidizing state.

  • PDF

A Study on Application of Stepwise Gate Signal for a-Si Gate Driver (a-Si Gate 구동회로의 Stepwise Gate 신호적용에 대한 연구)

  • Myung, Jae-Hoon;Kwag, Jin-Oh;Yi, Jun-Sin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.3
    • /
    • pp.272-278
    • /
    • 2008
  • This paper investigated the a-si:H gate driver with the stepwise gate signal. In 1-chip type mobile LCD application the stepwise gate signal for low power consumption can be used by adding simple switching circuit. The power consumption of the a-Si:H gate driver can be decreased by employing the stepwise gate signal in the conventional circuit. In conventional one, the effect of stepwise gate signal can decrease slew rate and increase the fluctuation of gate-off state voltage, In order to increase the slew rate and decrease the gate off state fluctuation, we proposed a new a-Si:H TFT gate driver circuit. The simulation data of the new circuit show that the slew rate and the gate-off state fluctuation are improved, so the circuit can work reliably.

A Study of the Analysis System of Remote Control a Voltage Fluctuation of a Based Wind Turbine (풍력기반 하이브레드 풍력발전기의 원격 정전압 변동률 분석 장치에 관한 연구)

  • Jang, Mi-Hye;Sun, Mean-Young;Lee, Jong-Jo;Lim, Jae-Kyoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.456-459
    • /
    • 2009
  • we studied a data acquisition and control system of a wind turbine for measuring and controlling a voltage fluctuations of a wind turbine system. The wind turbine system is installed out control area. So, it is so important for supervising to wind turbine of a maintenance, wind speed, optical resources wind turbine output, wind speed, wind direction, over voltage of a generator. This system can be supplied a data of over voltage, under voltage, voltage fluctuations of a wind turbine for controlling an EMS : Energy Management System or a SCADA : Supervision Control and Data Acquisition at a constitute of a wind farm. The of voltage fluctuation system of a wind turbine is improving an electric power supply power quality of a distribution line and unspecified individuals of used wind turbine.

  • PDF

A Study on Gas Pressure Fluctuation Characteristics inside Pipe Line Passing Through a Snubber at Hydrogen Compressor (수소압축기 스너버 관로 내부의 맥동파 특성에 관한 연구)

  • Shim, K.J.;Yi, C.S.;Akbar, Wanda Ali;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.165-171
    • /
    • 2006
  • An experiment to observe reduction of pressure fluctuation in the compressing system utilizing snubber has done. The experiment measured pressure at inlet and outlet of snubber. It used an air compressor as a model of hydrogen one. Snubber with buffer and snubber without buffer were used to get comprehensive comparison between both of that snubber. An analysis by using Fast Fourier Transform (FFT) method was conducted to verify working pressure frequency. With this method pure signal of static pressure was filtered from noisy signal. The experiment was run for several speeds of piston movement. It was controlled by adjustable frequency regulator that controled rotation of actuator motor. This was connected to the piston-reciprocating compressor with V-belt. From result obtained, the fluctuation was increasing proportionally when frequency of driver motor was increased.

  • PDF