• Title/Summary/Keyword: Power feedforward

Search Result 248, Processing Time 0.027 seconds

A Feedforward High Power Amplifier with Loops that can Reduce RX Band Noise as well as Intermodulation Distortion Signals (수신 대력 잡음과 혼변조 왜곡 신호 제거 루프를 갖는 Feedforward 대전력 증폭기 설계)

    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.2
    • /
    • pp.308-315
    • /
    • 2001
  • In this paper, a new power amplifier is proposed for reduction of amplified RX band noise signals as well as intermodulation distortion signals using feedforward technique. This power amplifier is implemented for IMT-2000 basestation TX frequency band. Both TX band intermodulation distortion signals and RX band noise signals are reduced by controlling variable attenuator, phase shifter and error amplifier. The proposed power amplifier, which contains two loops-intermodulation distortion signals cancellation loop and RX band noise signals cancellation loop, can provide duplexer with low TX path insertion loss for various wireless communication systems due to choice of loose RX attenuation characteristic. The principle of the proposed amplifier is described graphically based on the conceptual schematic diagram. A two-tone test for power amplifier is done at 2.14GHz with frequency spacing of 5MHz, and RX band rejection test is done over RX full band of 60MHz with 1.95GHz center frequency. Experimental results represent that the cancellation performance of intermodulation distortion signals and RX band noise signals are more than 3 1dB and 21dB, respectively.

  • PDF

The Order Selection of Equalizer in Feedforward Power Amplifier Linearizer using Adaptive Equalizer (적응 등화기를 이용한 Feedforward 선형증폭기에서의 등화기 차수 결정)

  • Chung, Jee-Sung;Yoo, Kyung-Yul
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.715-717
    • /
    • 1999
  • 본 논문에서는 feedforward 선형 증폭기에서의 지연 불일치에 의한 효과를 최소화하기 위한 등화기의 차수 결정에 관하여 수학적 접근과 모의실험을 하였다. 현재 feedforward 선형 증폭기에서 주로 사용하는 vector modulator는 지연 불일치에 확실한 개선을 이루지 못하고 있다. 이것을 극복하고자 vector modulator를 등화기로 대체하고 증폭기와 시지연선의 최대시간불일치와 sampling frequency와의 관계로 등화기의 차수를 결정하여 지연 불일치에 의한 오류 제거능력을 향상시켰다.

  • PDF

A Study on Implementation and Performance Evaluation of Error Amplifier for the Feedforward Linear Power Amplifier (Feedforward 선형 전력증폭기를 위한 에러증폭기의 구현 및 성능평가에 관한 연구)

  • Jeon, Joong-Sung;Cho, Hee-Jea;Kim, Seon-Keun;Kim, Ki-Moon
    • Journal of Navigation and Port Research
    • /
    • v.27 no.2
    • /
    • pp.209-215
    • /
    • 2003
  • In this paper. We tested and fabricated the error amplifier for the 15 Watt linear power amplifier for the IMT-2000 baseband station. The error amplifier was comprised of subtractor for detecting intermodulation distortion, variable attenuator for control amplitude, variable phase shifter for control phase, low power amplifier and high power amplifier. This component was designed on the RO4350 substrate and integrated the aluminum case with active biasing circuit. For suppression of spurious, the through capacitance was used. The characteristics of error amplifier measured up to 45 dB gain, $\pm$0.66 dB gain flatness and -15 dB input return loss. Results of application to the 15 Watt feedforward Linear Power Amplifier, the error amplifier improved with 27 dB cancellation from 34 dBc to 61 dBc IM$_3$.

Design of PI and Feedforward Controller for Precise Temperature Control of Oil Cooler System (오일쿨러의 고정밀 온도 제어를 위한 PI 및 피드포워드 제어기 설계)

  • Byun, J.Y.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.6
    • /
    • pp.89-95
    • /
    • 2010
  • This paper deals with design method of proportional-integral(PI) and feedforward controller for obtaining precise temperature and high energy efficiency of oil cooler system in machine tools. The compressor's speed and opening angle of an electronic expansion valve are controlled to keep reference value of temperature at oil outlet and superheat of an evaporator. Especially, the feedforward controller is added to suppress temperature fluctuation under abrupt disturbances. Through some experiments, the suggested method can control the target temperature within steady state error of ${\pm}0.l^{\circ}C$ and maximum overshoot $0.2^{\circ}C$ under abrupt disturbances.

BPF-based Grid Voltage Feedforward Control of Grid-connected Converters for Improving Robust Stability

  • Yang, Shude;Tong, Xiangqian;Yin, Jun;Wang, Haiyan;Deng, Yaping;Liu, Le
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.432-441
    • /
    • 2017
  • Grid voltage feedforward is extensively used for controlling grid-connected converters. However, the conventional voltage feedforward control reduces the stability margins of the converter connected to a high-impedance grid. The effect mechanism of voltage feedforward on the grid-connected converter control under high-inductive conditions of the grid impedance is clearly explained in this study using the equivalent transformations of control block diagrams. Results show that the delay produced by the digital control is the root cause of this effect. An improved voltage feedforward strategy, in which a bandpass filter (BPF) is introduced into the feedforward path, is proposed to strengthen the converter's robust stability against grid impedance variations. The selection method of the BPF's bandwidth is also provided considering the tradeoff between the response speed to the grid voltage sag and the system's robust stability. The converter can work stably over a wide range of the grid impedance through the proposed approach. Simulation and experimental results fully verify the effectiveness of the BPF-based voltage feedforward strategy.

A Study on the Efficiency Improvement of Linear Power Amplifier for Mobile Communication Repeater Applications (이동 통신 중계기용 선형 전력 증폭기 효율 개선에 관한 연구)

  • An, Jeong-Sig;Lee, Jong-Arc
    • Journal of IKEEE
    • /
    • v.3 no.2 s.5
    • /
    • pp.215-220
    • /
    • 1999
  • In fabricated linear power amplifier(LPA), the third-order inter-modulation distortion(IMD) for main amplifier alone is 10.61dBc, and the IMD for LPA with predistorter and feedforward loop combined is 32.50dBc. Therefore, the IMD characteristic results an improvement of approximately 22dB. The main amplifier efficiency with single tone input is close to 30%, and the efficiency of the overall LPA with predistorter is 27.4% and predicted feedforward loop efficiency without predistorter is about 20%. Therefore, LPA with predistorter and feedforward loop combined is improved by 7.4%.

  • PDF

The Development of High-Current Power Supply System for Electrolytic Copper Foil

  • Luo, An;Ma, Fujun;Xiong, Qiaopo;He, Zhixing
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.399-410
    • /
    • 2015
  • A 6.5 V/50 kA high-frequency switching power supply (HSPS) system composed of 10 power modules is developed to meet the requirements of copper-foil electrolysis. The power module is composed of a two-leg pulse width modulation (PWM) rectifier and a DC/DC converter. The DC/DC converter adopts two full-wave rectifiers in parallel to enhance the output. For the two-leg PWM rectifier, the ripple of the DC-link voltage is derived. A composite control method with a ripple filter is then proposed to effectively improve the performance of the rectifier. To meet the process demand of copper-foil electrolysis, the virtual impedance-based current-sharing control method with load current full feedforward is proposed for n-parallel DC/DC converters. The roles of load current feedforward and virtual impedance are analyzed, and the current-sharing control model of the HSPS system is derived. Virtual impedance is used to adjust the current-sharing impedance without changing the equivalent output impedance, which can effectively reduce current-sharing errors. Finally, simulation and experimental results verify the structure and control method.

A Seamless Transfer Algorithm Based on Frequency Detection with Feedforward Control Method in Distributed Generation System

  • Kim, Kiryong;Shin, Dongsul;Lee, Jaecheol;Lee, Jong-Pil;Yoo, Dong-Wook;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1066-1073
    • /
    • 2015
  • This paper proposes a control strategy based on the frequency detection method, comprising a current control and a feed-forward voltage control loop, is proposed for grid-interactive power conditioning systems (PCS). For continuous provision of power to critical loads, PCS should be able to check grid outages instantaneously. Hence, proposed in the present paper are a frequency detection method for detecting abnormal grid conditions and a controller, which consists of a current controller and a feedforward voltage controller, for different operation modes. The frequency detection method can detect abnormal grid conditions accurately and quickly. The controller which has current and voltage control loops rapidly helps in load voltage regulation when grid fault occurs by changing reference and control modes. The proposed seamless transfer control strategy is confirmed by experimental results.

A Study On the Feedforward Linear Power Amplifier Using Imperfect Signal Cancellation And Feedback (Imperfect Signal Cancellation과 Feedback을 이용한 Feedforward 선형전력증폭기에 관한 연구)

  • Park, Jung-Min;Yang, Seung-In
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.87-90
    • /
    • 2003
  • In this paper, A feedforward linear power amplifier is analyzed for imperfect signal cancellation and negative feedback for basestaion of IMT2000 band. the distortion generatied by the error amplifier is reduced using an imperfect signal cancellation for a 1-carrier WCDMA source by 4.3dB at 2.5MHz offset and 6dB at 5MHz offset of IMSR(intermodulation signal power ratio) compared to a perfect signal cancellation system. additionally, An imperfect signal cancellation using negative feedback improved 1.3dB and 8.2dB at 2.5MHz and 5MHz offset of IMSR compared to an imperfect signal cancellation.

  • PDF