• Title/Summary/Keyword: Power doppler

Search Result 187, Processing Time 0.029 seconds

A laser Doppler study of gingival blood flow change following periosteal stimulation (골막 자극 후 Laser Doppler Flowmetry를 이용한 치은혈류량 변화)

  • Lee, Ji-Young;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.2
    • /
    • pp.139-147
    • /
    • 2003
  • The roots of teeth exposed by gingival recession, may be successfully covered by various type of gingival grafting procedures. Vascularization of the recipient site is an essential determinant of the grafts' survival during the first healing stages. It has been suggested that a procedure by which they stimulate the periosteum presurgically will induce the proliferation of neo-endothelium in the site to be operated. The purpose of this study is to evaluate the variations in the gingival blood flow during 4weeks after periosteal stimulation in patient scheduled to receive gingival grafts and to compare variations in the gingival blood flow between smoker and non-smoker. Laser Doppler Flowmetry(floLAB(R), Moor Instruments Ltd, England ; wave length = 780mm. Max. power =l.6mW) was used to measure the gingival blood flow. 112 sites of 68 male patients (32 smokers and 36 non-smoker), aged between 23 and 48 years (smoker : 24-44 years. mean=32.6, non-smoker : 23-48 years, mean=28.5) were monitored for the blood flow. Gingival blood flow measured at before periosteal stimulation, 1-, 2-, 3-, and 4-weeks after periosteal stimulation from 10 a.m. to 2 p.m. The difference of blood flow in each measuring time, each measuring site and between smokers and non-smokers were statistically analyzed by MANOVA. The results were as follows : (1) Blood flow stayed increased for 2 weeks, and then, it was a tendency to decrease(p<0.05). (2) There was no statistically significant difference of blood flow change between smokers and non-smokers. (3)The blood flow at middle site had lower than mesial and distal site during the measuring periods(p<0.05). The present study suggested that blood flow change following periosteal stimulation was significant difference, thus periosteal stimulation before gingival graft might induce favorable results in gingival recession patient.

Investigation of the Performance of Spectral Domain Optical Doppler Tomography with High-speed Line Scanning CMOS Camera and Its Application to the Blood Flow Measurement in a Micro-tube

  • Park, Cheol Woo;Lee, Changho;Lim, SooHee;Ni, Aleksey;An, Jin Hyo;Lee, Ho;Bae, Jae Sung;Kim, Jeehyun
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.174-180
    • /
    • 2012
  • In this study, the feasibility of spectral domain optical Doppler tomography for measuring blood flow characteristics in a micro-tube was demonstrated through several experiments. The use of an SD-ODT system in blood flow measurement can provide high resolution images (5 microns resolution). We prepared three capillary tubes to reveal the effect of different concentrations of hematocrit ratio (HR). One tube serves as the control. The two other tubes contained different concentrations of HR (5%, 25%). Three different capillary tube inlet flow velocities were tested in the present study. The Reynolds number (Re) which is based on the capillary tube inner diameter ranges from Re=6 to 48. We calculated a Doppler shift of the power spectrum of the temporal interference fringes with Kasai autocorrelation function to achieve the velocity profile of the flow. As a result, SD-ODT systems could not detect the cell depletion layer in the present study due to the limitation of spatial resolution. Nevertheless, these systems were proven to be capable of observing the RBCs of blood.

Clinical Observation on Heart Rate Variability and Peripheral Blood Flow by Doppler Ultrasound in Healthy Subjects Stimulated by Cold Stress (정상인의 한냉자극에 대한 심박변이도 및 도플러 초음파 혈류계를 이용한 말초 혈류관찰)

  • Lim, Sung-Keun;Lee, Sang-Hoon;Bae, Young-Min
    • The Journal of Korean Medicine
    • /
    • v.31 no.2
    • /
    • pp.114-123
    • /
    • 2010
  • Objectives: This study was performed to investigate the effect of cold stress on heart rate variability and peripheral blood flow by Doppler ultrasound in healthy subjects. Methods: We classified the subjects by their Yin or Yang tendency using a Yin-Yang questionnaire. Cold stress was taken on the left hand of subjects for 10 seconds. Heart rate variability and peripheral blood flow were measured on the right radial artery before and after cold stress. Results: The Yang tendency group showed a significant decrease of heart rate after cold stress which was not seen in the Yin tendency group. The Yang tendency group showed a decrease of LF, total power, and increase of HF after cold stress, while the Yin tendency group showed the opposite. However, there were no statistically significant differences of heart rate variability analysis between the results of the two groups before and after cold stress. Recovery time of blood flow velocity by ultrasound Doppler was significantly different between the Yin and Yang tendency groups after cold stress. Conclusion: These results suggest that people with Yin or Yang tendency may show different responses in the autonomic nervous system. Further modified studies may include the responses to various manipulation techniques in acupuncture treatment and the individual responses according to pattern identification in traditional Korean medicine.

Performance Analysis of WFMT Modulation System Robust to ICI and Doppler Effect (부반송파간 간섭과 도플러 효과에 강한 WFMT 변조 방식의 성능 분석)

  • Kim, Seon-Ae;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.10
    • /
    • pp.1137-1146
    • /
    • 2008
  • OFDM is very effective for the high speed communication system. However, OFDM has the problems of high PAPR and serious ICI, which is different from the single carrier system. Especially, ICI problem caused by phase noise, Doppler effect and frequency offset is main reason for poor performance since it breaks down the orthogonality between subcarriers in OFDM communication system. Therefore, WFMT modulation scheme is studied and the effect of the carrier frequency offset and phase noise is analyzed. WFMT modulation scheme is based on the wavelet theory and complex filter banks for synthesis and analysis of multichannel signal. WFHT modulation scheme keeps on the advantage of filter banks system and can be easily possible for the implementation of filter banks. In this paper, we compare ISI and ICI distortions of the WFMT and OFDM system due to the carrier frequency offset and phase noise. Also, we analyze the PAPR and BER performances in the HPA and ICI situation caused by the Doppler frequency shift and the frequency offset.

Analysis of Gas-Solid Flow for the Optimum Design of Coal Splitter (입자분리기 최적 설계를 위한 다상 유동 해석)

  • Yok, Sim-Kyun;Ryu, Jae-Wook;Ik-Hyeong;Lee, Sang-Ryong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.11
    • /
    • pp.1604-1611
    • /
    • 2003
  • The experimental investigation of a coal splitter used in the 500㎿(e) boilers of fossil power plant is carried out to validate the design criteria. To predict air flow and the amount of particles at the exit, velocity and the weight of particles are measured on test planes using the coal splitter model with two-dimensional phase doppler particle analyzer and the glass fiber filter. It is found that the position of guide plate influences significantly both flow rates of gas and particle at the exit. Gas flow rate was a linear function of the guide plate, whereas particle flow rate was a exponential function of it.

MEASUREMENTS OF WATER SURFACE SLOPES BY MICROWAVE RADAR INSTALLED AT THE HELICOPTER

  • Karaev, Vladimir Yurjevich;Kanevsky, Mikhail Borisovich;Meshkov, Eugeny Mikhailovich;Zuikova, Emma Mikhailovna;Gol'blat, Vladimir Yurjevich;Titov, Viktor Ivanovich
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.348-351
    • /
    • 2006
  • Initial results of processing data from an experiment performed in November, 2005 are given. A microwave Doppler radar with a knife-like beam ($1.5^0$ - $24.5^0$) was installed on a helicopter. Measurements were made during a flight above the Gorky water storage basin. Power and Doppler spectra of the radar reflected signal were analyzed. The processing has shown that the algorithm developed for the retrieval of the slopes of rough water surface enables one to determine the direction of wave propagation and retrieve the variance of the wave slopes.

  • PDF

Localization of Rotating Sound Sources Using Beamforming Method (빔 형성 방법을 이용한 회전하는 음원의 위치 판별에 관한 연구)

  • 이재형;홍석호;최종수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.837-842
    • /
    • 2004
  • The positions of rotating sound sources have been localized by experiments with the Doppler effects removed. In order to do-Dopplerize the sound signals emitted from moving sources, two kinds of signal reconstruction methods were applied. One is the forward propagation method and the other is the backward propagation method. Forward propagation method analyze the source emission time based on the instantaneous distance between sensors and the assumed source position, then the signals are reconstructed with respect to the emission time. On the other hand, the backward method uses time delay to do-Dopplerize the acquired data for the received time of reference. In both techniques, the reconstructed signal data were processed using beamforming algorithm to produce power distributions at the frequency of interest. Experiments have been carried out for varying frequencies, rotating speeds and the object distances. Forward propagation method has shown better performance in locating source position than the backward propagation method.

  • PDF

Laser Doppler Vibrometer using the Bulk Homodyne Interferometer (호모다인 간섭계를 이용한 레이저 진동 측정기의 개발)

  • 라종필;경용수;왕세명;김경석;박기환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.397-402
    • /
    • 2003
  • The FM demodulation method for a bulk homodyne laser interferometer is presented. The Doppler frequency that represents the surface velocity of a vibrating object is obtained by using the bulk homodyne laser interferometer, and converted to the voltage signal by using the proposed analogue FM demodulation circuit. The DC offsets of the interferent signals that are obtained from the bulk homodyne interferometer are eliminated by using a simple subtraction. The new method for compensation of the asymmetry of each channels is presented. The light power variation of the interferometer is normalized by using the Auto Gain Controller(AGC). The proposed FM demodulation algorithm is proved by the theoretical method, and validated by the experimental results. In experiments, the proposed FM demodulation algorithm is compared with the conventional demodulation methods.

  • PDF

Performance Evaluation of Uplink OFDMA Systems (OFDMA 상향링크 시스템의 성능 분석)

  • Choi, Seung-Kuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2391-2397
    • /
    • 2007
  • I evaluate the BER performance of uplink OFDMA systems in time variant Rayleigh Doppler fading channel, considering the carrier frequency offset and the nonlinear high power amplifier. I obtain the required output back-off of the nonlinear amplifier and value of frequency offset for good BER performance. And I also analyze the BER degradation upon Doppler fading channel.

Design of X-Band SOM for Doppler Radar (도플러 레이더를 위한 X-Band SOM 설계)

  • Jeong, Sun-Hwa;Hwang, Hee-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.12
    • /
    • pp.1167-1172
    • /
    • 2013
  • This paper presents a X-band doppler radar with high conversion gain using a self-oscillating-mixer(SOM) that oscillation and frequency mixing is realized at the same time. To improve phase noise of the SOM oscillator, a ${\lambda}/2$ slotted square patch resonator(SSPR) was proposed, which shows high Q-factor of 175.4 and the 50 % reduced circuit area compared to the conventional resonator. To implement the low power system, low biasing voltage of 1.7 V was supplied. To enhance the conversion gain of the SOM, bias circuit is configured near the pinch-off region of transistor, and the conversion gain was optimized. The output power of the proposed SOM was -3.16 dBm at 10.65 GHz. A high conversion gain of 9.48 dB was obtained whereas DC Power consumption is relatively low about 7.65 mW. The phase noise is -90.91 dBc/Hz at 100 kHz offset. The figure-of-merit(FOM) of the proposed SOM was measured as -181.8 dBc/Hz, which is supplier to other SOMs by more than about 7 dB.