• Title/Summary/Keyword: Power connection point

Search Result 135, Processing Time 0.028 seconds

Improved ADALINE Harmonics Extraction Algorithm for Boosting Performance of Photovoltaic Shunt Active Power Filter under Dynamic Operations

  • Mohd Zainuri, Muhammad Ammirrul Atiqi;Radzi, Mohd Amran Mohd;Soh, Azura Che;Mariun, Norman;Rahim, Nasrudin Abd.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1714-1728
    • /
    • 2016
  • This paper presents improved harmonics extraction based on Adaptive Linear Neuron (ADALINE) algorithm for single phase photovoltaic (PV) shunt active power filter (SAPF). The proposed algorithm, named later as Improved ADALINE, contributes to better performance by removing cosine factor and sum of element that are considered as unnecessary features inside the existing algorithm, known as Modified Widrow-Hoff (W-H) ADALINE. A new updating technique, named as Fundamental Active Current, is introduced to replace the role of the weight factor inside the previous updating technique. For evaluation and comparison purposes, both proposed and existing algorithms have been developed. The PV SAPF with both algorithms was simulated in MATLAB-Simulink respectively, with and without operation or connection of PV. For hardware implementation, laboratory prototype has been developed and the proposed algorithm was programmed in TMS320F28335 DSP board. Steady state operation and three critical dynamic operations, which involve change of nonlinear loads, off-on operation between PV and SAPF, and change of irradiances, were carried out for performance evaluation. From the results and analysis, the Improved ADALINE algorithm shows the best performances with low total harmonic distortion, fast response time and high source power reduction. It performs well in both steady state and dynamic operations as compared to the Modified W-H ADALINE algorithm.

Effect on the Relay Contact Characteristics According to the Presence of Electrical Connection (릴레이 접점 특성에 미치는 전기적 접속의 영향)

  • Jin, In-Young;Choi, Sun-Ho;Kim, Kwan-Sik;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.10
    • /
    • pp.647-651
    • /
    • 2016
  • The power relay can easily control high voltage and high current through metallic contacts. In addition, it has the advantage in reasonable price. So it has been used in many applications. But the power relay has a weak point by mechanical movements. These mechanical movements cause the bouncing phenomenon. Arc and bouncing phenomenon are the main causes of electric abrasion and material erosion. In this study, mechanical repetitive experiments and repetitive experiments in electrically connected state are conducted. Then these two experimental results in terms of bouncing phenomenon and changes in the contact surface are compared. In all number of repetitions, contacts in an electrically connected state cause smaller number of bounce. Also, It has lower contents of silver on eroded surface than the other. The experimental results would be helpful to the further study of contacts life span.

Design and Implementation of a Current-balancing Circuit for LED Security Lights

  • Jung, Kwang-Hyun;Yoo, Jin-Wan;Park, Chong-Yeun
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.869-877
    • /
    • 2012
  • This paper presents a current-balancing circuit for security lights that uses parallel-connected LEDs. The parallel connection of LEDs causes current differences between the LED strings because of characteristic deviations. These differences can reduce the lifespan of a particular point of LEDs by thermal spotting. They can also cause non-uniform luminance of the lighting device. Among the different methods for solving these problems, the method using current-balancing transformers makes it easy to compensate for current differences and it has a simple circuitry. However, while the balancing transformer has been applied to AC light sources, LEDs operate on a DC source, so the driving circuitry and the design method have to be changed and their performances must be verified. Thus in this paper, a design method of the balancing transformer network and the driving circuitry for LEDs is proposed. The proposed design method could have a smaller size than the conventional design method. The proposed circuitry is applied to three types of 100-watt LED security lights, which use different LEDs. Experimental results are presented to verify the performance of the designed driving circuits.

A Study on the Contact Resistance according to the Tightening and Overlapping area of Bus Bar (부스 바의 체결 및 중첩 구간에 따른 접촉 저항에 관한 연구)

  • Kim, Hyun-Woo;Son, Yung-Deug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.56-62
    • /
    • 2018
  • The bus bar is an electrical connection widely used for the power supply of skyscrapers and power distribution and industrial equipment electrical panels in industrial plants. There are various materials to be considered in the design of the bus bar, such as material based on the use environment, the sectional area according to the power capacity, the length of the surface circumference, and the tightening method. Even with a bus bar manufactured to a size of sufficient power capacity in the design, if the actual tightening is incorrect, it may lead to fire due to deterioration. For these reasons, a variety of research on the temperature rise of the electrical contact point has continued. However, the temperature rise of the contacts is a consequence of the result, not a direct cause. In this paper, the influence of contact resistance on the fastening force and the overlapping section of the bus bar are investigated by measuring the change in resistance from building the specimen. A total of eight bus bar specimens were manufactured and measured. Resistance was measured by varying the clamping force and the interval between overlapping sections when the specimens were crossed. We propose a safe power connection model by analyzing the contribution of these factors to the actual contact resistance change.

Probabilistic Reliability Based HVDC Expansion Planning of Power System Including Wind Turbine Generators (풍력발전기를 포함하는 전력계통에서의 신뢰도 기반 HVDC 확충계획)

  • Oh, Ungjin;Lee, Yeonchan;Choi, Jaeseok;Yoon, Yongbeum;Kim, Chan-Ki;Lim, Jintaek
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.8-15
    • /
    • 2018
  • New methodology for probabilistic reliability based grid expansion planning of HVDC in power system including Wind Turbine Generators(WTG) is developed in this paper. This problem is focused on scenario based optimal selection technique to decide best connection bus of new transmission lines of HVDC in view point of adequacy reliability in power system including WTG. This requires two kinds of modeling and simulation for reliability evaluation. One is how is reliability evaluation model and simulation of WTG. Another is to develop a failure model of HVDC. First, reliability evaluation of power system including WTG needs multi-state simulation methodology because of intermittent characteristics of wind speed and nonlinear generation curve of WTG. Reliability methodology of power system including WTG has already been developed with considering multi-state simulation over the years in the world. The multi-state model already developed by authors is used for WTG reliability simulation in this study. Second, the power system including HVDC includes AC/DC converter and DC/AC inverter substation. The substation is composed of a lot of thyristor devices, in which devices have possibility of failure occurrence in potential. Failure model of AC/DC converter and DC/AC inverter substation in order to simulate HVDC reliability is newly proposed in this paper. Furthermore, this problem should be formulated in hierarchical level II(HLII) reliability evaluation because of best bus choice problem for connecting new HVDC and transmission lines consideration. HLII reliability simulation technique is not simple but difficult and complex. CmRel program, which is adequacy reliability evaluation program developed by authors, is extended and developed for this study. Using proposed method, new HVDC connected bus point is able to be decided at best reliability level successfully. Methodology proposed in this paper is applied to small sized model power system.

Simulation for Characteristics Analysis of Grid-connected Wind Power Generation System on MATLAB/Simulink (MATLAB/Simulink에서 계통연계 풍력발전시스템의 특성해석에 대한 시뮬레이션)

  • Ro, Kyoung-Soo;An, Hae-Joon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.18-25
    • /
    • 2008
  • The paper presents a modeling of the grid-connected wind turbine generation system on MATLAB/Simulink and aims to perform simulations for analysis of the system's characteristics. It performs a pitch regulation for control of the wind generator's output with respect to wind speed variation, and presents a relationship between interconnecting transformer's connections and fault current by reviewing the variations of fault current according to transformer connections in a grid-connected wind power generation system. It also investigates the effect of grounding methods of the interconnecting transformer's neutral point on fault current variations. The simulation results show the differences of fault currents, voltages and generator's characteristics for a line-to-ground fault according to interconnecting transformer's four different connections, and the differences of fault currents of the system according to grounding methods of the transformer neutral point. Therefore, the case studies demonstrate the effectiveness of the proposed simulation model on Simulink.

Analyses of Security into End-to-End Point Healthcare System based on Internet of Things (사물인터넷 기반의 헬스케어 시스템의 종단간 보안성 분석)

  • Kim, Jung Tae
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.6
    • /
    • pp.871-880
    • /
    • 2017
  • Recently, service based on internet is inter-connected and integrated with a variety of connection. This kind of internet of things consist of heterogenous devices such as sensor node, devices and end-to end equipment which used in conventional protocols and services. The representative system is healthcare system. From healthcare appliance used by IoT, patient and doctor can utilize healthcare information with safety and high speed management. It is very convenient management to operate mobility. But it induced security and vulnerability issues because it has small memory capacity, low power supply and low computing power. This made impossible to implement security algorithm with embedded engine based on hardware. Nowdays, we can't realize conventional standard algorithm due to these kinds of reasons. From the critical issues, it occurred security and vulnerability issues. Therefore, we analysed and compared with conventional method and proposed techniques. Finally, we evaluated security issues and requirement for end-to-end point healthcare system based on internet of things.

COMBINED ANALYTICAL AND EXPERIMENTAL INVESTIGATIONS FOR LWR CONTAINMENT PHENOMENA

  • Allelein, Hans-Josef;Reinecke, Ernst-Arndt;Belt, Alexander;Broxtermann, Philipp;Kelm, Stephan
    • Nuclear Engineering and Technology
    • /
    • v.44 no.3
    • /
    • pp.249-260
    • /
    • 2012
  • Main focus of the combined nuclear research activities at Aachen University (RWTH) and the Research Center J$\ddot{u}$lich (J$\ddot{U}$LICH) is the experimental and analytical investigation of containment phenomena and processes. We are deeply convinced that reliable simulations for operation, design basis and beyond-design basis accidents of nuclear power plants need the application of so-called lumped-parameter (LP) based codes as well as computational fluid dynamics (CFD) codes in an indispensable manner. The LP code being used at our institutions is the GRS code COCOSYS and the CFD tool is ANSYS CFX mostly used in German nuclear research. Both codes are applied for safety analyses especially of beyond design accidents. Focal point of the work is containment thermal-hydraulics, but source term relevant investigations for aerosol and iodine behavior are performed as well. To increase the capability of COCOSYS and CFX detailed models for specific features, e.g. recombiner behavior including chimney effect, building condenser, and wall condensation are developed and validated against facilities at different scales. The close connection between analytical and experimental activities is notable and identifying feature of the RWTH/J$\ddot{U}$LICH activities.

Development and Evaluation of an e-Learning Program for Mothers of Premature Infants (e-Learning을 이용한 미숙아 어머니 교육 프로그램 개발 및 평가)

  • Lee, Nae-Young;Kim, Young-Hae
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.1
    • /
    • pp.152-160
    • /
    • 2008
  • Purpose: It has been attempted to support mother of premature infants by providing information of premature infant care using e-Learning because premature infants need continuous care from birth to after discharge. Method: The e-Learning Program for mother of premature was developed with Xpert, Namo web editor, Adobe Photoshop, and PowerPoint and applied for 4 weeks from 4 to 30 September 2006. Result: 1) We found that the contents of information which premature infants' need when being in the hospital and after discharge were the definition of a premature infant, orientation of NICU, care of premature infants, care of premature infants' common diseases, the connection of healthcare resources, exchange of information, and the management of rearing stress. 2) The program content consisted of cause of premature birth, comparison to full-term baby, physiology character, orientation of NICU, common health problems, follow up care, infection control, feeding, normal development physically and mentally, weaning method, and vaccination. Conclusion: Considering the results, this program for mother of premature is a useful means to provide premature-care information to mothers. This information can be readily accessible and can be varied and complex enough to be able to help mothers to the information and assistance they require.

Study on Current Limiting Characteristics of YBCO Thin-Film Wire with Insulation Layer

  • Doo, Seung-Gyu;Du, Ho-Ik;Jeon, An-Gyoon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.1
    • /
    • pp.20-23
    • /
    • 2013
  • When applying superconducting wire to power machines, an investigation needs to be carried out on the characteristics of wire phase changes in connection with the insulating layer. This study examined trends in the increase of the wire's resistance and the characteristics of its recovery from quenching by a current-applied cycle at temperatures of 90 K, 180 K, and 250 K. The procedure was conducted based on the thickness and presence (or absence) of the insulating wire layers. To achieve this, YBCO thin-film wires with the same critical temperatures were prepared with copper and stainless steel stabilizing layers. At levels (-one, three, and five-), with superior performance, polyimide pressure-sensitive adhesive tape was attached to the wires at a very low temperature. The eight prepared test samples were wound around the linear frames. The wire's voltage and current created from the phase change characteristics were measured at the wire's prescribed temperature, using the four-point probe method. The wire's resistance and recovery characteristics were examined for each cycle at temperatures of 90 K, 180 K, and 250 K.