• Title/Summary/Keyword: Power angle

Search Result 2,368, Processing Time 0.03 seconds

An Adaptive Scheme for Frequency Measurement in Power System (적응기법을 이용한 전력계통의 주파수 측정)

  • Park, Cheol-Won;Nam, Si-Bok;Sin, Myeong-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.3
    • /
    • pp.143-152
    • /
    • 2002
  • Frequency is regarded as one of most important indices for the operating power systems. Several digital techniques for measuring frequency have been presented in the last decades. This paper proposes a design and implementation an adaptive scheme using phase angle difference calculation fort frequency measuring in power system. The advantages of the proposed technique are demonstrated by fault signals from EMTP simulation and user defined arbitrary signals by Excel program. The proposed technique is compared with the conventional methods. Performance teat results indicate that the proposed technique provides accurate measures in pretence of noise and harmonics and in case faults and is suitable for measurement near-nominal, nominal. and off-nominal frequencies. We can see that It will be useful in microprocessor based relays and digital metiers that need to measure power system frequency.

Estimation Technique of Frequency using FIR Filter in the Power System (FIR 필터를 이용한 전력계통의 주파수 추정기법)

  • 남시복;박철원;신명철
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.50 no.3
    • /
    • pp.101-108
    • /
    • 2001
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the Power system energy balance. This paper describes a digital signal processing technique for measuring the operating frequency of a power system. The fundamental frequency component of 3-phase signal is first extracted by using an algorithm based on FIR filter. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154KV double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

Power Line Extraction based on thermal Image (열영상 기반의 전력선검출)

  • Kim, Dong-Wook
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.3
    • /
    • pp.245-250
    • /
    • 2010
  • In this paper, an efficient extraction technique of power lines is proposed. Power line extraction technique is used to operate unmanned autonomous vehicles. To achieve the extraction of power lines, an angle space segmentation and grouping method of Hough transform are developed. In simulation results for the proposed algorithm, our algorithm shows a good detection results in experiments for several aerial images which contain different line components.

Numerical Analysis on Changes in Flowrate of Draft Water and Power by Changing Design Parameters of a Long-Distance Water Circulation (저층수 흡입식 광역 순환장치의 설계변수에 따른 배출량 및 소비동력 변화 특성에 대한 수치 해석 연구)

  • Song, Dong-Keun;Hong, Won-Seok;Kim, Young-Cheol;Park, Myong-Ha
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • A draft tube which has impeller to elevate bottom water and spread it over surface of lake water, induces convective circulation of lake water, a Long-Distance Circulation (LDC). Circulation of lake water make stratified water mixed and enhance DO (Dissolved Oxygen) of bottom water. Circulation rate of water is determined by draft rate of the tube, which is dependent on design parameters of the draft tube system, i. e. dimension of impeller and diffuser, inclined angle of impeller, impeller shape, and rotational speed. In this study, change in draft rate and power consumption of circulation equipment was investigated numerically with changing impeller dimension, angle and rotational speed. It was found that flowrate of draft water was increased as the dimensions of draft tube and impeller, and rotational speed and inclined angle of impeller increased. The power consumption was also elevated with increasing parameter values, and final selection of parameter values was made to satisfy target flowrates and power consumption.

Accurate Voltage Parameter Estimation for Grid Synchronization in Single-Phase Power Systems

  • Dai, Zhiyong;Lin, Hui;Tian, Yanjun;Yao, Wenli;Yin, Hang
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1067-1075
    • /
    • 2016
  • This paper presents an adaptive observer-based approach to estimate voltage parameters, including frequency, amplitude, and phase angle, for single-phase power systems. In contrast to most existing estimation methods of grid voltage parameters, in this study, grid voltage is treated as a dynamic system related to an unknown grid frequency. Based on adaptive observer theory, a full-order adaptive observer is proposed to estimate voltage parameters. A Lyapunov function-based argument is employed to ensure that the proposed estimation method of voltage parameters has zero steady-state error, even when frequency varies or phase angle jumps significantly. Meanwhile, a reduced-order adaptive observer is designed as the simplified version of the proposed full-order observer. Compared with the frequency-adaptive virtual flux estimation, the proposed adaptive observers exhibit better dynamic response to track the actual grid voltage frequency, amplitude, and phase angle. Simulations and experiments have been conducted to validate the effectiveness of the proposed observers.

Fabry-Perot Filter Constructed with Anisotropic Space Layer and Isotropic Mirrors

  • Qi, Hongji;Hou, Yongqiang;Yi, Kui;Shao, Jianda
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.33-37
    • /
    • 2013
  • In this study a new design concept of the Fabry-Perot filter, constructed with an anisotropic space layer and a couple of isotropic mirrors, was proposed based on the Maxwell equations and the characteristic matrix method. The single- and double-cavity Fabry-Perot filters were designed, and their optical properties were investigated with a developed software package. In addition, the dependence of the transmittance and phase shift for two orthogonal polarization states on the column angle of the anisotropic space layer and the incidence angle were discussed. We demonstrated that the polarization state of electromagnetic waves and phase shifts can be modulated by exploiting an anisotropic space layer in a polarization F-P filter. Birefringence of the anisotropic space layer provided a sophisticated phase modulation with varied incidence angles over a broad range, resulting in a wide-angle phase shift. This new concept would be useful for designing optical components with isotropic and anisotropic materials.

A Study on the Out-of-Step Detection Algorithm using Time Variation of Complex Power-Part I : The Variation of Complex Power trajectory in Complex plane (복소전력의 변화율을 이용한 동기탈조 검출 알고리즘에 관한 연구-Part I: 복소평면에서의 탁소전력의 궤적변화)

  • Kwon, O.S.;Kim, C.H.;Park, N.O.;Chai, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.310-312
    • /
    • 2005
  • An out-of-step condition results from the loss of the synchronism of the generators. A disturbance in a power system causes the generator angle to oscillate. When there is a severe disturbance such as a heavy current fault loss of major generation or loss of a large block of load the oscillation can be severe and even increase largely and finally the out-of-step condition may occur During the power swing and out-of-step conditions, the a apparent impedance at a relay location changes, and the power flow also changes as the angle difference is varied. This paper presents a method to analyze the trajectory of complex power during a power swing and out-of-step condition. The trajectory of the complex power is analyzed when a power swings and a fault occurs. Moreover, the complex power is analyzed when the ratios between the voltages at both sides and the line impedances are changed. These methods are verified through simulation using the ATP/EMTP MODELS.

  • PDF

Some Properties on Jacobian Matrix (전력조류방정식과 자코비안 행렬의 성질에 대하여)

  • Lee, Sang-Joong;Yang, Seong-Deog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.251-253
    • /
    • 2004
  • Though the reference angle has been specified conventionally on the slack bus, it can be specified on my bus in the system without changing power flow solutions. This paper describes that the loss sensitivity of the salk bus can be obtained through an angle reference transposition. A concept of two reference buses, consisting of "power slack bus"

  • PDF

Instantaneous Switching-Angle Control Scheme for Precise Speed Control of an SRM (SRM의 정밀속도제어를 위한 순시스위칭각 제어방식)

  • 안진우;오석규;황영문
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.3
    • /
    • pp.20-25
    • /
    • 1997
  • SRM은 많은 장점으로 인해 각종 산업분야에 적용을 검토하고 있다. 그러나 토오크리플과 소음이 교류전동기보다 상대적으로 높은 단점이 있다. SRM은 상전류파형이 동작특성과 토오크리플발생에 큰 영향을 미친다. 본 논문에서는 토오크리플을 줄이고 정밀한 속도제어를 위해 순시도통각제어와 PLK제어시스템을 이용하였다. PLL의 위상검출기는 도통각제어에, 루우프필터의 출력은 순시 인가전압의 제어에 각각 도입하여 속응성을 높이고 토오크리플을 줄일 수 있도록 하였다. 실험을 통하여 정밀한 속도제어와 토오크리플 저감특성을 확인할 수 있었다.

  • PDF

A study on Design for Radiation Element of Slotted Waveguide by the Method of Moment (모멘트법을 이용한 도파관 복사소자의 설계에 관한 연구)

  • 민경식;박세현;김동철;임학규
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.135-138
    • /
    • 2000
  • This paper presents design for radiation element of slotted waveguide by the method of moment. The piecewise sinusoidal function as the basis function is used for the Moment Method. From the analytically results based on the Galerkin's moment method, frequency characteristics and radiation power is investigated for the design parameter such as the slot length, offset and angle. This paper also discusses that the radiation power is controled by the slot offset and angle. The thickness of the waveguide wall is also discusses in the analysis.

  • PDF