• Title/Summary/Keyword: Power Up-Rate

Search Result 708, Processing Time 0.027 seconds

Warm Start Up Time Reduction Through the Increase of Boiler Water Circulating Pump Inlet Water Temperature Rate of the Thermal Power Plant (관수온도 상승률 증가에 의한 발전용 보일러의 온간기동시간 단축에 관한 연구)

  • Kang, Hee-Seong;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.10 no.1
    • /
    • pp.47-53
    • /
    • 2014
  • The national capacity of electricity of Korea was 81,737 MW and the peak demand was renewed by the record of 71,230 MW in 2012 which has been increasing since the first lighting ceremony had taken place in the Royal Palace(Kyung-Bok Goong) in 1887. Aa the counteract on the rapid increasing of the demand, Korean government is constructing and operating the high capacity nuclear and thermal power plants, however, the operating reserve on weekdays is small while those of weekends are more than 40% of capacity, so they are providing the pumped-storage power plants with the surplus electricity during weekends and operating the power plants which cost higher production price and located in the capital area with WSS (Weekly Start and Stop) mode including the Seoul Thermal Power Plant. Since the Seoul Thermal Power Plant is spending huge amount of expenses for more than 30 times of the WSS annually due to the high production cost even though it is in Seoul, the core of the demand, I chose the power plant unit #5 which was on the grid in 1969 for the case to confirm reducing 23% of the warm start-up time by applying the "Start-up time management program", and that reducing 35% of the water temperature increasing time by accelerate the increasing rate of the inlet temperature of the water circulating pump.

  • PDF

Etching Reaction of $UO_2\;with\;CF_4/O_2$ Mixture Gas Plasma

  • Kim, Yongsoo;Jinyoung Min;Kikwang Bae;Myungseung Yang
    • Nuclear Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.133-138
    • /
    • 1999
  • Research on the etching reaction of UO$_2$ with CF$_4$/O$_2$gas mixture plasma is carried out. The reaction rates are investigated as a function of CF$_4$/O$_2$ ratio, plasma power, and substrate temperature. It is found that there exists an optimum CF$_4$/O$_2$ ratio around 4:1 at all temperatures up to 37$0^{\circ}C$ and surface analysis using XPS X-ray Photoelectron Spectroscopy) confirms the result. Peak rate at the optimum gas composition increases with increasing temperature. Highest rate obtained in this study leaches 1050 monolayers/min. at 37$0^{\circ}C$ under r. f. power of 150 W, which is equivalent to about 0.5${\mu}{\textrm}{m}$/min. The rate also increases with increasing r. f. power, thus, higher power and higher substrate temperature will undoubtedly raise the etching reaction rate much further. This reaction seems to be an activated process, whose activation energy will be derived in the following experiments.

  • PDF

An Empirical Study on the Operation of Cogeneration Generators for Heat Trading in Industrial Complexes

  • Kim, Jaehyun;Kim, Taehyoung;Park, Youngsu;Ham, Kyung Sun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.3
    • /
    • pp.29-39
    • /
    • 2019
  • In this study, we introduce a model that satisfies energy efficiency and economical efficiency by introducing and demonstrating cogeneration generators in industrial complexes using various actual data collected at the site. The proposed model is composed of three scenarios, ie, full - time operation, scenario operated according to demand, and a fusion type. In this study, the power generation profit and surplus thermal energy are measured according to the operation of the generator, and the thermal energy is traded according to the demand of the customer to calculate the profit and loss including the heat and evaluate the economic efficiency. As a result of the study, it is relatively profitable to reduce the generation of the generator under the condition that the electricity rate is low and the gas rate is high, while the basic charge is not increased. On the contrary, if the electricity rate is high and the gas rate is low, The more you start up, the more profit you can see. These results show that even a cogeneration power plant with a low economic efficiency due to a low "spark spread" has sufficient economic value if it can sell more than a certain amount of heat energy from a nearby customer and adjust the applied power through peak management.

Properties of Thermoelectric Power in PbS Thin Films by Chemical Bath Deposition (화학 반응에 의한 PbS 박막의 열기전력 특성)

  • Cho, Jong-Rae;Cho, Jung-Ho;Kim, Kang-Eun;Chung, Su-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.21-24
    • /
    • 2000
  • Properties of thermoelectric power in PbS thin films by chemical bath deposition were investigated The qualified PbS thin film was gained with the amounts of Thiourea($4-8ml/{\ell}$ ), Triethanolamine (1-2ml) and NaOH(l0ml). The molecular ratio of Pb and S was 3 : 7. Satisfied crystallization rate and deposition rate of PbS were greater at $50^{\circ}C$ than at $30^{\circ}C$. The constant of thermoelectric power in PbS was nearly $ 500uv/^{\circ}k$. The PbS thin film was changed from p-type to n-type semiconductor at around $200^{\circ}C$. In case of heat treatment at $300^{\circ}C$, the sample kept the characteristic of p-type semiconductors up to $250^{\circ}C$.

  • PDF

A Power-based Pipelined-forwarding MAC Protocol for Energy Harvesting Wireless Sensor Networks (에너지 하베스팅 무선 센서네트워크을 위한 전력기반 Pipelined-forwarding MAC프로토콜)

  • Shim, Kyuwook;Park, Hyung-Kun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.98-101
    • /
    • 2019
  • In this paper, we propose the power-based pipelined-forwarding MAC protocol which can select relay nodes according to the residual power and energy harvesting rate in EH-WSN (energy-harvesting wireless sensor networks). The proposed MAC follows a pipelined-forwarding scheme in which nodes repeatedly sleep and wake up in an EH-WSN environment and data is continuously transmitted from a high-level node to a low-level node. The sleep interval is adaptively controlled so that nodes with low energy harvesting rate can be charged sufficiently, thereby minimizing the transmission delay and increasing the network lifetime. Simulation shows that the proposed MAC protocol improves the balance of residual power and network lifetime.

The Study on a Flow-rate Calculation Method by the Pump Power in the Axial Flow Pumps (축류형 펌프에서 펌프전력을 이용한 유량산정 방범에 관한 연구)

  • Lee, Jun;Seo, Jae-Kwang;Park, Chun-Tae;Kim, Young-In;Yoon, Ju-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.3
    • /
    • pp.227-231
    • /
    • 2004
  • It is the common features of the integral reactors that the main components of the RCS are installed within the reactor vessel, and so there are no any flow pipes connecting the steam generator or the pump whose type is the axial flow. Due to no any flow pipes, it is impossible to measure the differential pressure at the RCS of the integral reactors, and it also makes impossible measure the flow-rate of the reactor coolant. As a alternative method, the method by the measurement of the pump power of the axial flow pump has been introduced in this study. Up to now, we did not found out a precedent which the pump power is used for the flow-rate calculation at normal operation of the commercial nuclear power plants. The objective of the study is to embody the flow-rate calculation method by the measurement of the pump power in an integral reactor. As a result of the study, we could theoretically reason that the capacity-head curve and capacity-shaft power curve around the rated capacity with the high specific-speeded axial flow pumps have each diagonally steep incline but show the similar shape. Also, we could confirm the above theoretical reasoning from the measured result of the pump motor inputs. So, it has been concluded that it is possible to calculate the flow-rate by the measurement of the pump motor inputs.

  • PDF

Influence of Frequency on Electromagnetic Field of Super High-Speed Permanent Magnet Generator

  • Qiu, Hongbo;Wei, Yanqi;Wang, Wei;Tang, Bingxia;Zhao, Xifang;Yang, Cunxiang
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.980-988
    • /
    • 2019
  • When compared with traditional power frequency generators, the frequency of a super high-speed permanent magnet generator (SHSPMG) is a lot higher. In order to study the influence of frequency on the electromagnetic field of SHSPMGs, a 60000rpm, 117kW SHSPMG was taken as a research object. The two-dimensional finite element model of the generator was established, and the two-dimensional transient field of the generator was simulated. In addition, a test platform of the generator was set up and tested. The reliability of the simulation was verified by comparing the experiment data with that of the simulation. Then the generator electromagnetic field under different frequencies was studied, and the influence mechanism of frequency on the generator electromagnetic field was revealed. The generator loss, voltage regulation rate, torque and torque ripple were analyzed under the rated active power load and different frequencies. The influences of frequency on the eddy current density, loss, voltage regulation rate and torque ripple of the generator were obtained. These conclusions can provide some reference for the design and optimization of SHSPMGs.

Contact oxide etching using $CHF_3/CF_4$ ($CHF_3/CF_4$를 사용한 콘택 산화막 식각)

  • 김창일;김태형;장의구
    • Electrical & Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.774-779
    • /
    • 1995
  • Process optimization experiments based on the Taguchi method were performed in order to set up the optimal process conditions for the contact oxide etching process module which was built in order to be attached to the cluster system of multi-processing purpose. In order to compare with Taguchi method, the contact oxide etching process carried out with different process parameters(CHF$_{3}$/CF$_{4}$ gas flow rate, chamber pressure, RF power and magnetic field intensity). Optimal etching characteristics were evaluated in terms of etch rate, selectivity, uniformity and etched profile. In this paper, as a final analysis of experimental results the optimal etching characteristics were obtained at the process conditions of CHF3/CF4 gas flow rate = 72/8 sccm, chamber pressure = 50 mTorr, RF power = 500 watts, and magnetic field intensity = 90 gauss.

  • PDF

Role of the Baseline Heart Rate Variability to the Effect of the Huanglian-Jie-Du Granule in Hwa-Byung Patients: Supplementary Analysis from the Randomized Trial Comparing Huanglian-Jie-Du Granule and Placebo for Hwa-Byung (화병 환자의 심박변이도 차이에 따른 황련해독탕의 효과: 화병에 대한 무작위 대조 비교임상시험 결과의 추가 분석)

  • Choi, Yu-Jin;Cho, Seung-Hun
    • Stress
    • /
    • v.26 no.4
    • /
    • pp.305-311
    • /
    • 2018
  • Background: The purpose of the study was to explore whether the effect of Huanglian-jie-du granule depends on the baseline heart rate variability in patients with Hwa-byung. Methods: We used the supplementary data from a randomized, double-blind, placebo-controlled trial of Huanglian-jie-du granule for Hwa-byung patients. Study drugs were taken orally three times per day for one week. Heart rate variability was measured three times; before the treatment, after the treatment, and month follow-up period. Spearman's rho test was done to explore the role of the baseline heart rate variability to the effect of Huanglian-jie-du granule. Results: Baseline low frequency power of heart rate variability was negatively correlated with the reduction of the insomnia severity index in experimental group (r=-0.493 p=0.02). Also, Huanglian-jie-de granule significantly decreased the low frequency power of heart rate variability in patients with Hwa-byung compared to placebo (mean difference 266 [95% CI: 29~503], p=0.028). In Hwa-byung symptoms, stuffy, pushing up in the chest, and flush of anger were correlated with low frequency power of heart rate variability (p=0.010, p=0.000, and p=0.016, respectively). Conclusions: The effect of the Huanglian-jie-de granule for insomnia seems to be lower when the baseline low frequency power of heart rate variability is higher in Hwa-byung patients. Also, Huanglian-jie-de granule is likely to decrease the sympathetic activity in patients with Hwa-byung. Measurement of heart rate variability may be the useful to understand the state of Hwa-byung patients.

A Study on Profitability of Power Plant for Landfill Gas (매립가스 자원화를 위한 가스엔진 발전의 수익성에 관한 연구)

  • Kim, O-U;Lee, Jeong-Il
    • 한국산학경영학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.147-170
    • /
    • 2006
  • Landfill gas is a mixture of methane and carbon dioxide produced by the bacterial decomposition of organic wastes, and it is considered to produce bad smells and pollute the environment. Economic trials and the developments of landfill gas, as an alternative energy resource, become known at the recent years, Resource development of landfill gas, which is managed by Korea up to now, is for the most part generation using gas engine. Medium BTU and High BTU are considered for the power generation as well. Most income of generation using gas engine is selling charge through a power plant. Expecting to manage the power plant for up to 10 years, the analysis based on revenue and expenditure shows when the unit price is 65.2 Won and the operating rate reaches 90%, it is possible to be into the black in 2012 without considering additional financial expense, It was also analyzed that the profit at a unit price of 85 Won under the anticipated rising unit price by the operating rate of 71% is larger than at the operating rate of 90% under limited unit price of 65.2 Won. It means to manage the power plant at a unit price of 65.2 Won and the operating rate must be higher than 90% for economic logicality. If we assume that the operating rate is 90% and it increases the unit price, the unit price must be higher than 85 Won for the management of a power plant. Analysis of changing a unit price, however, might be expected to have a gradual rise of prices. If there is no price rising and additional income related to CDM(Clean Development Mechanism) and emission trading upon Kyoto protocol, the management of a power plant using gas engine will get financial difficulties because of many operating expenses. However, since landfill gas is considered as a worthy energy resource for the guarantee of sustainable development and for the equity between recent generation and future generation, the development of it must be accomplished by the government's additional supporting and efforts under the interest of all stakeholder who are involved.

  • PDF