• Title/Summary/Keyword: Power Up-Rate

Search Result 700, Processing Time 0.031 seconds

Assisted Flow Rate Characteristics in Hydraulic Power Steering System (유압식 파워 스티어링 시스템의 어시스트 유량 특성)

  • Lee, Byung-Rim;Ryu, Sang-Woock;You, Chung-Jun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.1
    • /
    • pp.58-63
    • /
    • 2009
  • Flow rate of the power steering oil pump is affected by oil temperature, engine rpm and pressure of pump. In this paper, considering those conditions, approximate model expressed by flow rate characteristics between hydraulic power steering oil pump and steering gear is proposed. Oil pump displacement is considered to be 9.6cc/rev. which is adapted to mid size car. Flow rate of the oil pump is predicted from the proposed model and compared with experimental data. And catch-up is also predicted in each steering wheel speed and is compared with experimental results.

BLOW-UP RATE FOR THE SEMI-LINEAR WAVE EQUATION IN BOUNDED DOMAIN

  • Liang, Chuangchuang;Wang, Pengchao
    • Bulletin of the Korean Mathematical Society
    • /
    • v.52 no.1
    • /
    • pp.173-182
    • /
    • 2015
  • In this paper, the blow-up rate of $L^2$-norm for the semi-linear wave equation with a power nonlinearity is obtained in the bounded domain for any p > 1. We also get the blow-up rate of the derivative under the condition 1 < p < $1+\frac{4}{N-1}$ for $N{\geq}2$ or 1 < p < 5 for N = 1.

Spectral Analysis of Heart Rate Variability during Treadmill Exercise at Various Speeds and Grades

  • Kim, Hyeong-Jin;Kim, Ki-Hong;Ahn, Dong-Kuk;Park, Jae-Sik
    • The Korean Journal of Physiology
    • /
    • v.30 no.1
    • /
    • pp.43-51
    • /
    • 1996
  • This study was aimed to elucidate the changes in heart rate variability during treadmill exercise at various speeds and grades by spectral analysis. Thirty-three untrained male college students aged $20{\sim}26\;yr $were employed to exercise on a treadmill using 4 speeds (4.02, 5.47, 6.76 and 8.05 km/h) and 6 grades (0, 4, 8, 12, 16 and 20%). A fixed speed was selected for each session with the grade increased every 3 min. The electrocardiogram, respiration and the stepping activity were continuously recorded through an A/D converter system on the computer disk. Power spectra of heart rate variability (RRV) were obtained by use of a fast Fourier transform algorithm. The frequency domain was divided into 3 bands: $VLF\;(0{\sim}0.04\;Hz),\;LF\;(0.04 {\sim}0.15\;Hz)\;and\;HF\;(0.15{\sim}1.00\;Hz).$ Heart rate was $74.4{\pm}2.1\;beats/min$ at rest and showed a steady increase during treadmill exercise with increasing speed and grade up to $196.7{\pm}5.0\;beats/min.$ Total power of HRV was $35.0{\pm}6.7\;(beats/min)^{2}$ at rest and progressively decreased during exercise down to $1.9{\pm}0.3\;(beats/min)^{2}.$ The %VLF power of HRV was $34.5{\pm}3.7\; %$ at rest and showed no significant change during exercise except for a decrease observed at the highest intensity of exercise. The %LF power was $44.1{\pm}3.0\;%$ at rest and showed a progressive decrease down to $4.5{\pm}1.0\;%$ during those stages of exercise where heart rate was over 135 beats/min. The %HF power was $21.4{\pm}2.9\;%$ at rest and showed a progressive increase up to $87.1{\pm}6.7\;%$ during higher intensity exercise where heart rate was over 165 beats/min. Peak frequency of HF band was $0.200{\pm}0.018\;Hz$ at rest and was shifted to higher frequencies up to $0.909{\pm}0.048\;Hz$ at heart rates greater than 135 beats/min. Respiratory frequency was $18.0{\pm}1.5$ breaths/min at rest and significantly increased during exercise up to $53.0{\pm}3.7$ breaths/min. Stride frequency during treadmill exercise showed an increasing tendency with increasing speed from $55.6{\pm}0.9$ steps/min at 4.02 km/h to $81.2{\pm}0.6$ at 8.05 km/h. It was concluded that total power of HRV decreased progressively with increasing exercise intensity due to the withdrawal of parasympathetic activity. At higher exercise intensity, % LF power decreased and %HF power increased with its peak frequency shifted to higher values in a progressive mode with increasing speed and grade, reflecting a readjustment in the cardiovascular system and the increased respiration and its rate, respectively.

  • PDF

Effects of child pick-up behavior on emergency evacuations

  • Jang, Sang Hoon;Hwang, Ha;Chung, Ji-Bum
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2519-2528
    • /
    • 2022
  • The child pick-up behavior of parents during an emergency can cause heavy traffic congestion and failing to evacuate an affected area successfully. In this study, we analyzed the effect of child pick-up behavior using, as an example, a nuclear power plant accident caused by an earthquake, which is a typical no-notice emergency. A quake was assumed to occur near the Shin-Kori nuclear power plant in Ulsan, Korea, resulting in a nuclear power plant accident. An agent-based dynamic simulation model using VISSIM was employed to conduct sensitivity analyses with different child pick-up rates. The results confirmed that parents are a major cause of congestion and a vulnerable class in an emergency evacuation. The child pick-up behavior caused significant traffic congestion, and parents who pick up their children showed a higher evacuation failure rate.

Excessive Leakage Measurement Using Pressure Decay Method in Containment Building Local Leakage Rate Test at Nuclear Power Plant (원전 격납건물 국부누설률시험에서의 압력감소법을 이용한 과다누설 측정 방법)

  • Lee, Won Kyu;Kim, Chang Soo;Kim, Wang Bae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.3
    • /
    • pp.231-235
    • /
    • 2016
  • There are two methods for conducting the containment local leakage rate test (LLRT) in nuclear power plants: the make-up flow rate method and the pressure decay method. The make-up flow rate method is applied first in most power plants. In this method, the leakage rate is measured by checking the flow rate of the make-up flow. However, when it is difficult to maintain the test pressure because of excessive leakage, the pressure decay method can be used as a complementary method, as the leakage rates at pressures lower than normal can be measured using this method. We studied the method of measuring over leakage using the pressure decay method for conducting the LLRT for the containment building at a nuclear power plant. We performed experiments under conditions similar to those during an LLRT conducted on-site. We measured the characteristics of the leakage rate under varies pressure decay conditions, and calculated the compensation ratio based on these data.

Analysis of Cell Latch-up Effect in SRAM Device (SRAM 소자의 Cell Latch-up 현상 분석)

  • Lee Jun-Ha;Lee Hoong-Joo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.11a
    • /
    • pp.203-205
    • /
    • 2004
  • A soft error rate neutrons is a growing problem for terrestrial integrated circuits with technology scaling. In the acceleration test with high-density neutron beam, a latch-up prohibits accurate estimations of the soft error rate (SER). This paper presents results of analysis for the latch-up characteristics in the circumstance corresponding to the acceleration SER test for SRAM. Simulation results, using a two-dimensional device simulator, show that the deep p-well structure has better latch-up immunity compared to normal twin and triple well structures. In addition, it is more effective to minimize the distance to ground power compared with controlling a path to the $V_{DD}$ power.

  • PDF

Study on the measuring system of power quality for transmission system (송전계통의 전기품질 측정 시스템에 관한 연구)

  • Kim Yeoung-Noh;Shin Bong-Il;Lee Hee-Chul;Kwak No-Hong;Jeon Young-Soo;Park Sang-Ho;Lee Il-Moo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.432-434
    • /
    • 2006
  • The additional matters appear to be considered in several aspects for building up power-quality measuring system of transmission system(high voltage system) compared to distribution system(middle or low voltage system). Like in distribution system, input signals are also received from PT and CT source of voltage and current respectively in transmission system and applied in accordance with a certain rate. In this case, very big error rate can be occurred according to the specification of the measuring system as the applying rate is bigger than in distribution system beyond comparison. In addition, when the abnormal signal occurred such as sag/swell, interruption, transient etc., power quality of other sires linked to the system also should be checked to find the accurate cause of the abnormal power-quality signals from the corresponding. site. Accordingly, the accurate diagnosis on the condition of power quality for the system depends on the way how the synchronization system is brought along for each site. This paper will suggest the solution for the most effective system building focused on how to solve the problem of the error rate and synchronization described in the above when building up the measuring system of power quality for transmission system.

  • PDF

Optimal Criterion for the Scale-Up Production of Schizophyllan in the Stirred Tank Reactor

  • KWAK, JUNG-KI;KOO, JAE-GUEN;PARK, SUNG-WOO;CHO, MAN-GI;KANG, BYEONG-CHUL;RAINER BUCHHOLZ;PETER GOETZ
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • Optimal criterion for the scale-up production of schizophyllan, a fungal polysaccharide secreted by Schizophyllum commune, was investigated. For the production of the polysaccharide in a 150-l bioreactor, the culture conditions optimized in a 15-l bioreactor were applied to a 150-l bioreactor with scale-up process, by changing impeller speed and airflow rate. The optimized impeller speed in the 15-l bioreactor was 50 rpm in a technical medium based on barley. For establishment of the scale-up process, 3 kinds of criteria were used while the gas throughput number was kept constant, as follows; constant volume-related power input, constant tip speed of stirrer, and constant Reynolds number. In the 150-l bioreactor, the highest values for the maximum specific growth rate (1.17/day) and productivity (0.63 g/L${\cdot}$day) were achieved in the culture condition from constant volumerelated power input criterion.

Super-Regenerative Receiver for low power consumption and short range wireless communication (저전력 근거리 통신을 위한 재생 수신기)

  • Song, Jun;Park, Sung-Min;Kim, Ki-Hun;Lee, Moon-Que
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.156-158
    • /
    • 2006
  • A super-regenerative receiver is designed and tested at 433 MHz ISM band, The designed receiver has the data rate of up to 200 kbps and a power consumption of 10 mW. We carried out the system performance test for the TX power of 0.1 mW and 1 m distance. The result of the bit-error rate test shows one bit error among the 4000 bits.

  • PDF

Study on the measuring system of power quality for transmission system (송전계통의 전기품질 측정 시스템에 관한 연구)

  • Kim, Yeoung-Noh;Shin, Bong-Il;Lee, Hee-Chul;Kwak, No-Hong;Jeon, Young-Soo;Park, Sang-Ho;Lee, Il-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.107-109
    • /
    • 2006
  • The additional matters appear to be considered in several aspects for building up power-quality measuring system of transmission system(high voltage system) compared to distribution system(middle or low voltage system). Like in distribution system, input signals are also received from PT and CT source of voltage and current respectively in transmission system and applied in accordance with a certain rate. In this case, very big error rate can be occurred according to the specification of the measuring system as the applying rate is bigger than in distribution system beyond comparison. In addition, when the abnormal signal occurred such as sag/swell, interruption, transient etc., power quality of other sites linked to the system also should be checked to find the accurate cause of the abnormal power-quality signals from the corresponding site. Accordingly, the accurate diagnosis on the condition of Power quality for the system depends on the way how the synchronization system is brought along for each site. This paper will suggest the solution for the most effective system building focused on how to solve the problem of the error rate and synchronization described in the above when building up the measuring system of power quality for transmission system.

  • PDF