• 제목/요약/키워드: Power System Measurement

검색결과 2,050건 처리시간 0.029초

DSP를 적용한 전력용 DC 평활 커패시터의 이더넷 원격 고장진단시스템 개발 (A Development of Ethernet-Based Remote Diagnosis System for DC Voltage Smoothing Capacitor using DSP)

  • 손진근
    • 전기학회논문지P
    • /
    • 제60권2호
    • /
    • pp.94-98
    • /
    • 2011
  • Electrolytic power capacitors today form essential components for virtually any power electronic system such as DC/DC converter or UPS. Frequently, electrolytic capacitors for DC link voltage smoothing are the key components which determine the life cycle of the whole unit and often are responsible for converter breakdown failures. In this paper, ethernet-based remote diagnosis system for DC voltage smoothing capacitor using DSP control board is developed. To estimate the status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The ESR detection scheme is based on the determination of the capacitor ripple power losses calculated from DC link voltage/current measurement. Experimental results show the veridity and reliability of the proposed ethernet-based remote on-line capacitor diagnosis system.

초음파 핵연료 세정장비의 시스템 구성과 제거된 크러드의 정량적 무게 측정법 (System Configuration of Ultrasonic Nuclear Fuel Cleaner and Quantitative Weight Measurement of Removed CRUD)

  • 신중철;이학윤;성운학;주영종;김용찬;한욱진
    • 한국압력기기공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.1-6
    • /
    • 2024
  • Crud is a corrosion deposit that forms in equipments and piping of nuclear reactor's primary systems. When crud circulates through the reactor's primary system coolant and adheres to the surface of the nuclear fuel cladding tube, it can lead to the Axial Offset Anomaly (AOA) phenomenon. This occurrence is known to potentially reduce the output of a nuclear power plant or to necessitate an early shutdown. Consequently, worldwide nuclear power plants have employed ultrasonic cleaning methods since 2000 to mitigate crud deposition, ensuring stable operation and economic efficiency. This paper details the system configuration of ultrasonic nuclear fuel cleaning equipment, outlining the function of each component. The objective is to contribute to the local domestic production of ultrasonic nuclear fuel cleaning equipment. Additionally, the paper introduces a method for accurately measuring the weight of removed crud, a crucial factor in assessing cleaning effectiveness and providing input data for the BOA code used in core safety evaluations. Accurate measurement of highly radioactive filters containing crud is essential, and weighing them underwater is a common practice. However, the buoyancy effect during underwater weighing may lead to an overestimation of the collected crud's weight. To address this issue, the paper proposes a formula correcting for buoyancy errors, enhancing measurement accuracy. This improved weight measurement method, accounting for buoyancy effects in water, is expected to facilitate the quantitative assessment of filter weights generated during chemical decontamination and system operations in nuclear power plants.

Stochastic Stability Analysis of the Power System Incorporating Wind Power using Measurement Wind Data

  • Parinya, Panom;Sangswang, Anawach;Kirtikara, Krissanapong;Chenvidhya, Dhirayut
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1110-1122
    • /
    • 2018
  • This paper proposes an alternative method to evaluate the effect of wind power to the power system stability with small disturbance. Alternatively, available techniques for stability analysis of a power system based on deterministic methods are less accurate for high penetration of wind power. Numerical simulations of random behaviors are computationally expensive. A stochastic stability index (SSI) is proposed for the power system stability evaluation based on the theory of stochastic stability and energy function, specifically the stochastic derivative of the relative well-defined energy function and the critical energy. The SSI is implemented on the modified nine-bus system including wind turbines under different conditions. A doubly-fed induction generator (DFIG) wind turbine is characterized and modeled using measured wind data from several sites in Thailand. Each of the obtained wind power data is analyzed. The wind power effect is modeled considering the aggregated effect of wind turbines. With the proposed method, the system behavior is properly predicted and the stability is quantitatively evaluated with less computational effort compared with conventional numerical simulation methods.

전력계통 상태 추정에서의 불량정보 검출기법 (Bad Data Detection Method in Power System State Estimation)

  • 최상봉;문영현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.239-243
    • /
    • 1990
  • This paper presents a algorithm to improve accuracy and reliability in state estimation of contaminated bad data. The conventional algorithms for detection of bad data confront the problems of excessive memory requirements and long computation time. In order to overcome measurement compensation approach is proposed to reduce computation time and partitioned measurement error model has the advantage of remarkable reduction in computation time and memory requirements in estimated error computation. The proposed algorithm has been tested for IEEE sample systems, which shows its applicability to on-line power systems.

  • PDF

대형 송전선로에 의한 TV 전파장해 고찰 (Ghost and Blocking of TV signal by UHV Transmission Lines)

  • 신구용;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1776-1778
    • /
    • 1998
  • KEPCO has been constructing the 765 kV double circuit transmission line since 1997. It is worried that the 765 kV transmission lines make TV interference(Ghost and Blocking) due to high tower and multi sub-conductors. This paper presents the mechanism, the measuring method and the results of TV ghost and blocking measurement using a new TV ghost measurement system in a vehicle which was developed by KEPRI.

  • PDF

전력계통 상태주정에서의 불량정보 검출기법 (Bad Data Detection Method in Power System State Estimation)

  • 최상봉;문영현
    • 대한전기학회논문지
    • /
    • 제40권2호
    • /
    • pp.144-153
    • /
    • 1991
  • This paper presents an algorithm to improve accuracy and reliability in the state estimation of contaminated bad data. The conventional algorithms for detection of bad data have the problems of excessive memory requirements and long computation time. In order to overcome these problems, a measurement compensation approach is proposed to reduce computation time, and the partitioned measurement error model has the advantage of remarkable reduction in computation time and memory requirements in estimated error computation. The proposed algorithm has been tested for IEEE sample systems, which shows its applicability to on-line power systems.

전력량 측정에 대한 불확도 평가 및 감소 방법 (Measurement uncertainty's evaluation and reduction method for electric power measuring)

  • 정주영;김익수;김민규;허종철;박찬교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1782-1784
    • /
    • 2003
  • This paper evaluates the uncertainty to measurement of the power of measuring system used in the performance evaluation of electrical apparatus and introduces the reduction method of the uncertainty.

  • PDF

압축성유체 유량계측장치 설계 및 제작 (Design and Building of Flow-rate Measurement Apparatus for Compressible Fluid)

  • 지상원;장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제10권4호
    • /
    • pp.29-33
    • /
    • 2013
  • Pneumatic system is widely applied in various industry because it have a many advantage(low cost, high safety, etc..). For design of pneumatic system, accurate flow measurement is required. In this study, compressible fluid flow measurement apparatus was designed and built. It uses an isothermal chamber that can approximate isothermal condition. Therefore, it can be measured for flow-rate using pressure response of isothermal chamber. As a result, this apparatus can be measured for sonic conductance and critical pressure ratio of pneumatic components and it required less time and energy than conventional flow meter. The effectiveness of the designed apparatus is proved by experimental result.

Distance Measurement by Automatic Peak Detection for Indoor Positioning Using Spread Spectrum Ultrasonic Waves

  • Suzuki, Akimasa;Miyara, Yasuaki;Iyota, Taketoshi;Kim, Young-Bok;Choi, Yong-Woon
    • 동력기계공학회지
    • /
    • 제19권2호
    • /
    • pp.33-39
    • /
    • 2015
  • In conducting indoor positioning by code division multiple access using spread spectrum ultrasonic waves, it is required to detect signals under the influence of near-far problem occurred by difference on signal power, caused by distance between transmitter and receiver. For discussing robustness to the problem, we verified measuring accuracy on distance from an experiment on a real space with a hardware device where our proposed method is mounted. The proposed method performs automatic signal detection by setting threshold level dynamically. As an experimental result, measurable distance were improved by the proposed method, and measurement errors were up to 50mm in distances from 1000mm to 6000mm; therefore, enough accuracy to realize self-localization or navigation for autonomous mobile robot or human was obtained.

RFID 파워 컨트롤을 이용한 이동로봇의 위치 추정에 관한 연구 (Research about RFID make use of power control on Localization of mobile robot)

  • 정기호;장철웅;심현민;장승관;이응혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.557-559
    • /
    • 2006
  • In this paper we analyze whether recent Radio Frequence Identification technology can be used to improve the localization of mobile robot and persons in their environment. In particular we study the problem of localizing RFID tags with a mobile platform that is equipped with a pair of RFID antennas. This system make use of power control because Tag with Reader distance measurement. We are accurately the low at former time than the environment. A distance measurement is rather correct. This system uses 900MHz Frequencies.

  • PDF