• 제목/요약/키워드: Power System Effect

검색결과 3,472건 처리시간 0.027초

SNA 기반 네트워크 파워를 이용한 지상전장정보체계 전투력 효과측정 모델제안 (A Proposal of Combat Power Measurement Model of Army Warfare Information System Using Network Power based on Social Network Analysis)

  • 정치영;이재영
    • 한국경영과학회지
    • /
    • 제36권4호
    • /
    • pp.1-16
    • /
    • 2011
  • It is important not only to introduce the C4I(Command and Control, Communication, Computer, Intelligence) system for realizing the NCW(Network Centric Warfare) but also to evaluate the synergistic effect by the C4I system. However, the study effort for evaluating the system's synergistic effect is insufficient compared with introducing the system. Therefore, in this paper, we proposed a model that measures the synergistic effect of combat power by the warfare information system. To measure the synergistic effect of warfare information system, the network power must be considered, so we also proposed a new methodology for measurement of network power based on SNA(Social Network Analysis), not Metcalfe's law. A model we proposed is a model that measures the raised combat power by the network effectiveness. The methodology and model we proposed in this paper will be used usefully to analyze the practical effect of constructing future warfare information system.

가정용 연료전지 시스템의 계통연계 시 수용가 및 배전계통에서의 고조파 영향 평가 (An Assessment on Harmonics Effect in Customer and the Distributed Power System during Grid Connection of Residential Fuel Cell System)

  • 박찬엄;정진수;한운기
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1280-1285
    • /
    • 2011
  • Recently, due to the use of fossil fuels for electric power production, carbon emissions increased excessively. Thereby, in order to replace fossil fuels, many studies about fossil fuels such as solar and fuel cell energy source are progressing. Fuel cell system has high energy conversion efficiency. Also, fuel cell system is environmentally friendly system because the carbon emission is almost not occur. Therefore, the fuel cell system is considered as the core technology of in the fields of the future energy and environmental. Fuel cell system has an effect on distribution power system because another power source of other than large power plants. So, fuel cell system can be degradation reason of power quality in the power system. In this paper, we constructed the system for an assessment on harmonics effect. The system is composed with power source, harmonics generation and linear load, fuel cell system. we also performed assessment on harmonics effect in customer and the distributed power system during grid connection of residential fuel cell system. An assessment cases are divided into three. A Case 1 is state that residential load and fuel system are connected to grid, Case 2 is state that residential load and harmonics load are connected to grid, and Case 3 is state that all loads are connected to grid. As a output of fuel cell system is increase, analysis results based on assessment system showed that power quality became more aggravation as effect of harmonics.

Stochastic Stability Analysis of the Power System Incorporating Wind Power using Measurement Wind Data

  • Parinya, Panom;Sangswang, Anawach;Kirtikara, Krissanapong;Chenvidhya, Dhirayut
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1110-1122
    • /
    • 2018
  • This paper proposes an alternative method to evaluate the effect of wind power to the power system stability with small disturbance. Alternatively, available techniques for stability analysis of a power system based on deterministic methods are less accurate for high penetration of wind power. Numerical simulations of random behaviors are computationally expensive. A stochastic stability index (SSI) is proposed for the power system stability evaluation based on the theory of stochastic stability and energy function, specifically the stochastic derivative of the relative well-defined energy function and the critical energy. The SSI is implemented on the modified nine-bus system including wind turbines under different conditions. A doubly-fed induction generator (DFIG) wind turbine is characterized and modeled using measured wind data from several sites in Thailand. Each of the obtained wind power data is analyzed. The wind power effect is modeled considering the aggregated effect of wind turbines. With the proposed method, the system behavior is properly predicted and the stability is quantitatively evaluated with less computational effort compared with conventional numerical simulation methods.

전력계통 고장시 계통연계형 태양광발전시스템의 영향분석 (Analysis of the Effect of the Grid-connected Photovoltaic System in Fault Case of Power System)

  • 박성훈;이용식;정성원;김재현
    • 한국태양에너지학회 논문집
    • /
    • 제39권4호
    • /
    • pp.69-77
    • /
    • 2019
  • Among the main functions of the grid-connected photovoltaic (PV) system, the anti-islanding operation function is a very important problem. Recently, due to the improvement in power generation efficiency and the maintenance advantages in PV system, the use of string inverter has increased so that the possibility of islanding operation has been raised. Generally, when a power system faults, the PV inverter must be disconnected from power system within 10 cycles by the anti-islanding operation function. However, in the real-time of power system, the output power of the PV system within 10cycles is effected. In this paper, we analyzed the effect of grid-connected PV system on power quality in a short time within 10 cycles on fault case of power system using the Matlab Simulink program.

Utility Interactive PV Systems with Power Shaping Function for Increasing Peak Power Cut Effect

  • Choe, Gyu-Ha;Kim, Hong-Sung;Heo, Hye-Seong;Jeong, Byong-Hwan;Choi, Young-Ho;Kim, Jae-Chul
    • Journal of Power Electronics
    • /
    • 제8권4호
    • /
    • pp.371-380
    • /
    • 2008
  • This paper describes the Utility Interactive PV (UIPV) system which can improve the peak-cut effect by adding an energy storage device of batteries to the power converter. The proposed system has three possible operation modes depending on relative condition of PV output, which can have the power shaping function covering the peak power for 3 hours. A new power circuit and an application algorithm have been applied to the UIPV system which is based on working PV system during a 3-hour peak time. The energy relationship by the proposed system is analyzed theoretically and experimentally. The proposed system is evaluated at the viewpoint of cost and total spacing, which enables the proposed UIPV system to have the reduction of the peak power demand and hence to improve the power capacity of peak cut.

Primary Restoration Path Selection Considering Ferranti Effect and Reactive Power Capability of Black-start Generators

  • Park, Ji-Man;Lee, Heung-Jae;Yu, Won-Kun;Jang, Byung-Tae;Lee, Kyeong-Seob
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1377-1382
    • /
    • 2015
  • Power system restoration following a massive blackout starts with re-energizing Primary Restorative Transmission (PRT) systems at first. As power systems have been gradually enlarged and become more complex, periodical evaluation and reassignment of PRTs are needed. So far it has been decided by try and error approach by corresponding human experts to analyze and evaluate them. This paper presents an intelligent system that finds optimal primary restoration paths using analytic and heuristic knowledge from PSS/E data, and suggests an optimal PRTs depending on the condition of Ferranti effect or a reactive power capability margin of black-start generator. This system was tested in Korea Electric Power system, and showed a promising result.

초전도 한류기 적용시 배전계통의 신뢰도 비용 평가 (Reliability Cost Evaluation of Power Distribution System with Superconducting Fault Current Limiter)

  • 문종필
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.266-270
    • /
    • 2014
  • In this paper, the effects of superconducting fault current limiter (SFCL) installed in power distribution system on reliability are evaluated and analyzed. The fault current will be decreased in power distribution system with SFCL because of the increased impedance of SFCL. The decreased fault current will improve the voltage drop of the bus of substation. The voltage drop is an important factor of power distribution system reliability. In this paper, improvement of reliability worth is analyzed when SFCLs are installed at the starting point in power distribution system. First, resistor-type SFCL model is used in PSCAD/EMTDC. Next, typical power distribution system is modeled. Finally, when the SFCLs with impedance 0.5 [${\Omega}$] are installed in feeder, power distribution system reliability is evaluated. Also, the improvement effect of reliability worth including the effect of voltage sag is analyzed using customer interruption cost according to whether or not SFCL is installed.

첨두부하 삭감효과를 갖는 UIPV시스템의 개선된 운용방법 (Improved Operating Method of Utility Interactive PV System for Peak Power Cut Effect)

  • 김영식;바이스갈랑;허혜성;최규하
    • 전력전자학회논문지
    • /
    • 제14권5호
    • /
    • pp.415-422
    • /
    • 2009
  • 본 논문은 기존의 시스템에 비해 시스템의 전력회로 구조의 큰 변경 없이 밧데리와 같은 전력저장 장치 디바이스의 추가와 개선된 운용방법을 적용한 첨두부하 삭감효과를 갖는 계통연계형 태양광발전시스템(UIPV)을 제안하였다. 개선된 운용방법과 에너지 저장장치의 추가로 기존 시스템에 비해 PV-array 용량을 작게 설치하여도 첨두부하 삭감효과를 크게 할 수 있으며, 가격 및 설치공간 등의 면에서 평가하여 기존시스템보다 더 나아짐을 확인하였다.

안테나 배열을 이용한 CDMA 셀룰라 시스템에서 불완전 전력제어가 역방향 채널 용량에 미치는 효과 (The effect of imperfect power control on the capacity of reverse channel in cellular CDMA system with antenna arrays)

  • 김씨알;오성근
    • 한국통신학회논문지
    • /
    • 제21권2호
    • /
    • pp.471-482
    • /
    • 1996
  • In this paper, we analyze the effect of imperfect power control on the capacity of the reverse channel in CDMA cellular system with antenna arrays in the base station. For imperfect power control, we assume that the received power at the base station from the users within each cell has log-normal distribution, and we also consider the effect of imperfect power control of co-channel interferences which arise from both its own cell and outer cells. From the result of numerical analysis, we show that the degree of power control gives a great influence on the capacity of CDMA celluar system with antenna arrays, and also that antenna arrays at the base station can improve greatly the system capacity even when the power control is imperfect.

  • PDF

The Failure Analysis of Paralleled Solar Array Regulator for Satellite Power System in Low Earth Orbit

  • Jang, Sung-Soo;Kim, Sung-Hoon;Lee, Sang-Ryool;Choi, Jae-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • 제28권2호
    • /
    • pp.133-141
    • /
    • 2011
  • A satellite power system should generate and supply sufficient electric power to perform the satellite mission successfully during the satellite mission period, and it should be developed to be strong to the failure caused by the severe space environment. A satellite power system must have a high reliability with respect to failure. Since it cannot be repaired after launching, different from a ground system, the failures that may happen in space as well as the effect of the failures on the system should be considered in advance. However, it is difficult to use all the hardware to test the performance of the satellite power system to be developed in order to consider the failure mechanism of the electrical power system. Therefore, it is necessary to develop an accurate model for the main components of a power system and, based on that, to develop an accurate model for the entire power system. Through the power system modeling, the overall effect of failure on the main components of the power system can be considered and the protective design can be devised against the failure. In this study, to analyze the failure mode of the power system and the effects of the failure on the power system, we carried out modeling of the main power system components including the solar array regulator, and constituted the entire power system based on the modeling. Additionally, we investigated the effects of representative failures in the solar array regulator on the power system using the power system model.