• Title/Summary/Keyword: Power System Analysis

Search Result 9,426, Processing Time 0.043 seconds

Characteristic analysis of inductive power transfer system by parameter variation (파라미터 변화에 따른 유도급전 시스템 특성해석)

  • Lee, Byung-Song;Bae, Chang-Han;Han, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.215-217
    • /
    • 2004
  • This paper shows the analysis of the inductive power transfer system in conjunction with series resonant converter operating variable high frequency. Of particular interest is the sensitivity of the complete system to variations in operational frequency and parameters. In inductive power transfer system, electrical power is transferred from a primary winding in the form of a coil or track, to one or more isolated pick-up coils that may relative to the primary. The ability to transmit power without contact enables high reliability and easy maintenance that allows inductive power transfer system to be implemented in hostile environments. This technology has found application in many fields such as electric vehicles, PRT(Personal Rapid Transit) etc. The coupling between the primary and secondary is then presented to include the effects of parameter and operational frequency variation.

  • PDF

The Algorithm Development on Harmonic Analysis for Estimating the Quality of 1-Phase/3-Phase Power System (단상/삼상 계통 전력 품질 평가를 위한 고조파 분석 알고리즘 개발)

  • Jong-Su Lim;Taeck-Kie Lee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • With the development of technology, a new class of smaller and more sensitive electrical systems have emerged, requiring higher quality power system. Improving the quality of the power system requires removing harmonics as much as possible to ensure better efficiency. We should first collect information on what harmonic frequencies are included in the current power system to remove the harmonics. In this paper, a new frequency analysis algorithm is introduced for a three-phase and a 1-phase power system. MTE PRS 600.3 is used to generate any harmonics to ensure that the algorithm performs well. Typing any harmonics on the Windows GUI program shows the analyzed result from the board developed for the algorithm.

Development of Performance Analysis System (NOPAS) for Turbine Cycle of Nuclear Power Plant

  • Kim, Seong-Kun;Park, Kwang-Hee
    • Nuclear Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.34-45
    • /
    • 2001
  • We have needs to develop a performance analysis system that can be used in domestic nuclear power plants to determine performance status of turbine cycle. We developed new NOPAS system to aid performance analysis of turbine cycle . Procedures of performance calculation are improved using several adaptations from standard calculation algorithms based on ASME (American Society of Mechanical Engineers) PTC (Performance Test Code). Robustness in the performance analysis is increased by verification & validation scheme for measured input data. The system also provides useful aids for performance analysis such as graphic heat balance of turbine cycle and components, turbine expansion lines, automatic generation of analysis reports.

  • PDF

Low Cost High Power Density Photovoltaic Power Conditioning System with an Energy Storage System

  • Jang, Du-Hee;Han, Sang-Kyoo
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.487-494
    • /
    • 2012
  • A new low cost high power density photovoltaic power conditioning system (PV PCS) with an energy storage system is proposed in this paper. Its high power density and cost effectiveness can be achieved through the unification of the maximum power point tracker and the battery charger/discharger. Despite the reduced power stage, the proposed system can achieve the same performance in terms of maximum power point tracking and battery charging/discharging as the conventional system. When a utility power failure happens, the proposed system cannot perform maximum power point tracking at the UPS mode. However, the predetermined battery voltage near the maximum power point of the PV array can effectively generate a reasonable PV power even at the UPS mode. Therefore, it features a simpler structure, less mass, lower cost, and fewer devices. Finally, to confirm the operation, validity, and features of the proposed system, a theoretical analysis and experimental results from a single phase AC 220Vrms/1.5kW prototype are presented.

Development of Data Aquisition System for Electrical Power Analysis of Electrical Load equipments (전기부하설비의 전력분석을 위한 데이터 획득 시스템의 개발)

  • 이상익;전정채;유대근
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.60-66
    • /
    • 2004
  • In order to analyze voltage, current electrical power, harmonic and so on of electrical load equipments, electrical power analysis by real measurement rather than mathematical modeling is necessary, and plan of countermeasure for efficient management, energy frugality and accident prevention of electrical equipments using it is possible Especially, electrical power analysis by real measurement is indispensable in order to consider countermove of harmonic occurred by nonlinear load So, in this paper, we developed DSP(Digital Signal Processor) based low price date aquisition system, and verified it's ability by performing measurement and analysis of electrical power and harmonic in the real power system.

Robust Stability Analysis of STATCOM System for Power Quality Enhancement (전력 품질 개선을 위한 STATCOM 시스템의 강인 안정도 해석)

  • Sung, Hwa-Chang;Park, Jin-Bae;Tak, Myung-Hwan;Joo, Young-Hoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.2
    • /
    • pp.220-225
    • /
    • 2010
  • This paper deals with the robust stability analysis of STATCOM (Static Synchronous Compensator) power system for power quality enhancement and power system stability. The STATCOM plays an important role in controlling the reactive power flow to the power network and hence the system voltage fluctuations and stability. The control areas of this plant are very large and the overall composition of the system is nonlinear. Also, STATCOM is influence of the uncertainties so that it is necessary to apply the new control technique. For solving these problems, we perform the fuzzy modeling and robust analysis for STATCOM system.

Modelling and simulation of the grid-interactive inverter (계통연계형 인버터의 모델링 및 시뮬레이션)

  • An, Gyo-Sang;Im, Hui-Cheon
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1345-1347
    • /
    • 2002
  • This paper describes the computer simulation results of the photovoltaic(PV) power system for the grid-connection. The major contents of this paper consist of the modeling of the PV power system for grid-connection, the analysis of the steady-state characteristics of the system, and the analysis of the transient-state characteristics of the system, respectively.

  • PDF

Harmonic Analysis of TCSC Power Transmission System considering Load Characteristics (부하 특성을 고려한 TCSC 전력송전 시스템의 고조파 해석)

  • 정교범
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.468-471
    • /
    • 2000
  • This paper investigates the harmonics of TCSC power transmission system having nonlinear VI characteristic loads. Nonlinear VI characteristic components are modelled with Nortons harmonic current sources. The system parameters such as line impedances admittances and node voltages and the thyristor switching action are described in complex Fourier series. EMTP simulation studies with a detailed three-phase TCSC power transmission system are also performed in order to verify the harmonic analysis at the steady state.

  • PDF

Performance Evaluation of an Oxy-coal-fired Power Generation System - Thermodynamic Evaluation of Power Cycle (순산소 석탄 연소 발전 시스템의 성능 평가 - 동력 사이클의 열역학적 해석)

  • Lee, Kwang-Jin;Choi, Sang-Min;Kim, Tae-Hyung;Seo, Sang-Il
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.2
    • /
    • pp.1-11
    • /
    • 2010
  • Power generation systems based on the oxy-coal combustion with carbon dioxide capture and storage (CCS) capability are being proposed and discussed lately. Although a large number of lab scale studies for oxy-coal power plant have been made, studies of pilot scale or commercial scale power plant are not enough. Only a few demonstration projects for oxy-coal power plant are publicized recently. The proposed systems are evolving and various alternatives are to be comparatively evaluated. This paper presents a proposed approach for performance evaluation of a commercial 100 MWe class power plant, which is currently being considered for 'retrofitting' for the demonstration of the concept. The system is configurated based on design and operating conditions with proper assumptions. System components to be included in the discussion are listed. Evaluation criteria in terms of performance are summarized based on the system heat and mass balance and simple performance parameters, such as the fuel to power efficiency and brief introduction of the second law analysis. Also, gas composition is identified for additional analysis to impurities in the system including the purity of oxygen and unwanted gaseous components of nitrogen, argon and oxygen in air separation unit and $CO_2$ processing unit.

Comparative Performance Evaluation of Si MOSFET and GaN FET Power System (Si MOSFET과 GaN FET Power System 성능 비교 평가)

  • Ahn, Jung-Hoon;Lee, Byoung-Kuk;Kim, Jong-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.283-289
    • /
    • 2014
  • This paper carries out a series of analysis of power system using Gallium Nitride (GaN) FET which has wide band gap (WBG) characteristics comparing to conventional Si MOSFET-used power system. At first, for comparison of each semiconductor device, the switching-transient parameter is quantitatively extracted from released information of GaN FET. And GaN FET model which reflect this dynamic property is configured. By using this model, the performance of GaN FET is analyzed comparing to Si MOSFET. Also, in order to enable a representative assessment on the power system level, Si MOSFET and GaN FET are applied to the most common structure of power system, full-bridge, and each power systems are compared based on various criteria, such as performance, efficiency and power density. The entire process is verified with the aid of mathematical analysis and simulation.