• 제목/요약/키워드: Power System Analysis

검색결과 9,415건 처리시간 0.04초

상태변수들의 관계지수를 이용한 전력시스템 동적 축약기법 연구 (A Study on Coherency Aggregation Method Using Relation Index of State Variables in the Power System)

  • 이병하;백정명
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1367-1372
    • /
    • 2007
  • The modem large electric power system has made power system analysis much more complex and difficult. For effective analysis of the power system, model reduction and aggregation is required. In this paper, a new relation index to identify the coherency among the generators is presented and also a new aggregation method is presented to aggregate the coherent generators in the large scale power system while matching the power flow. In order to demonstrate the effects of this aggregation method, it is applied to the IEEE 39 bus test power system and to the 2006 summer power system of Korea Electric Power Corporation, and the simulation results are compared with those of the original system.

석유 시추선 전력 계통의 과도 안정도 해석 (Analysis on transient stability for drilling rigs power system)

  • 김윤식;김철호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1119-1124
    • /
    • 2014
  • 본 논문은 석유시추선의 전력 계통 시스템의 비상시 전력 계통 해석에 대하여 기술하였다. 특히 석유시추선의 추진부하와 발전기의 탈락으로 인해 발생하는 전력계통 시스템에 미치는 영향을 검토하였다. 또한 고정 여자방식과 조속기의 제어 변수를 조정하여 임의의 사고 전후 정상상태로의 복귀까지 과도 안정도 해석으로 전력계통에 나타나는 현상을 관찰하였다. 전력계통 설계와 해석 및 과도 현상해석 프로그램인 ETAP(Electrical Transient Analysis Program)을 사용하였으며, 수치해석의 결과를 도출하여 그 특성을 분석하였다.

객체지향 데이터베이스를 이용한 전력계통 해석 (Power System Analysis using OODB)

  • 박지호;백용식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권5호
    • /
    • pp.257-265
    • /
    • 2004
  • The complex documentation involved in power system analysis software require a well-defined and friendly database system. We have developed an object-oriented database management system for power system analysis, and have described load flow analysis and transient stability analysis using object-oriented database(OODB). Database management systems are widely used and achieve high reliability of data management in the engineering fields. However relational database system have shortcomings in application to power system analysis. ill relational database, the data model is too simple for modeling complex data and database languages are very different from programming languages. Object-oriented techniques are sufficiently powerful to support data-modeling requirements of GUI applications. The GUI is implemented using C++ on a MS windows platform. The OODB supports data modeling requirements of GUI applications and the performance is well acceptable for Gill applications.

상이형전자계산기에 의한 영월.부평간 송전계통의 과도안전도 해석 (Transient stability analysis of the Yongwol.Bupyong power system by electronic analog computer techniques)

  • 한만춘
    • 전기의세계
    • /
    • 제15권1호
    • /
    • pp.14-19
    • /
    • 1966
  • Transient stability analysis of Yongwol-Bupyong power system, which contains Yongwol steam power station, the largest one in Korea, was undertaken by using the Yonsei 101 Analog computer. The critical switching time and phase angle for the present 150MW power flow to be stable were found. And the transient stability power limit for the system was also found. It is concluded that the system becoms unstable if the power flow increases much more than 151MW.

  • PDF

정상상태에서의 최적전압제어 기법에 관한 연구 (A Study on The Steady State Voltage Control Technique)

  • 원종률;윤용범;윤종수;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.214-216
    • /
    • 1998
  • This paper presents the analysis on the voltage problems of Korea electric power system and efficient voltage control actions, when contingencies are considered. This analysis is based on the developed voltage' control techniques. It uses the reactive power-voltage nonlinear characteristics. Therefore, efficient voltage control actions can be obtained. Principal control actions of the program are mainly switched shunt capacitor and generator voltage regulating. This is tested on Korea real power system in future year.

  • PDF

전력계통의 종합적인 해석을 위한 대화형 소프트웨어의 개발 (Development of Interactive Software for Integrated Analysis in Power System)

  • 신명철;홍진표;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.252-255
    • /
    • 1990
  • Analyzing and simulating of today's complex electrical networks require the use of computer-aided engineering tools. In recent years, the rapid advances in micro-computer hardware technology have increased the availability of power application software on the personal computer, once the domain of mainframes and minicomputers, enabling efficient and cost-effective power system analysis. An interactive simulation and analysis software for a power system is developed and presented in this paper. The software is written in PASCAL and is designed for PC use. This paper presents an integrated software package to run PC-DOS for the analysis of electric power networks. The software is menu driven and controlled by prompts. These programs are intended to help users understand the process of power system analysis and design.

  • PDF

SNA 기반 네트워크 파워를 이용한 지상전장정보체계 전투력 효과측정 모델제안 (A Proposal of Combat Power Measurement Model of Army Warfare Information System Using Network Power based on Social Network Analysis)

  • 정치영;이재영
    • 한국경영과학회지
    • /
    • 제36권4호
    • /
    • pp.1-16
    • /
    • 2011
  • It is important not only to introduce the C4I(Command and Control, Communication, Computer, Intelligence) system for realizing the NCW(Network Centric Warfare) but also to evaluate the synergistic effect by the C4I system. However, the study effort for evaluating the system's synergistic effect is insufficient compared with introducing the system. Therefore, in this paper, we proposed a model that measures the synergistic effect of combat power by the warfare information system. To measure the synergistic effect of warfare information system, the network power must be considered, so we also proposed a new methodology for measurement of network power based on SNA(Social Network Analysis), not Metcalfe's law. A model we proposed is a model that measures the raised combat power by the network effectiveness. The methodology and model we proposed in this paper will be used usefully to analyze the practical effect of constructing future warfare information system.

한전 전력계통의 저주파 진동현상 요인분석;양수발전기 기동시 (Analysis of the Factors Affecting Low-Frequency Oscillations in KEPCO Power System` With Pumped-Storage Plant)

  • Kil Yeong Song;Sae Hyuk Kwon;Kyu Min Ro;Seok Ha Song
    • 대한전기학회논문지
    • /
    • 제41권8호
    • /
    • pp.841-849
    • /
    • 1992
  • In power system operation, the stability of synchronous machine has been recognized one of the most important things. AESOPS program developed by EPRI in U.S.A. is a frequency domain analysis program in power system stability and it computes the electro-mechanical oscillation mode. This paper presents how to analyze the power system small signal stability problem efficiently by uusing the AESOPS program and analyze the various factors affecting the damping characteristics of these oscillations in KEPCO power system of 1986 with pumped-storage plant. To reduce the computing time and efforts, selecting the poorly-damped oscillation mode and clustering technique have been used. The characteristics of load, the amount of power flow on the transmission line and the gain of exciter have a significant effects on the damping of the system while the governing system has only a minor one. With the Power System Stabilizers, the stability of the power system has been improved.

  • PDF

Design of Battery System for Smoothing Wind Power Variations in Power System based on Frequency Response Analysis

  • Nakajima, Kyouhei;Umemura, Atsushi;Takahashi, Rion;Tamura, Junji
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권3호
    • /
    • pp.342-348
    • /
    • 2013
  • As a number of wind power generation systems have been installed in power systems in the world, frequency fluctuations due to output power variations from wind farms have become a serious problem. Battery systems have been studied for smoothing the output variations and decreasing the resulting frequency fluctuations. Among these studies, efficient design of battery systems is one of the most important subjects from a point of view of cost. This paper presents a comparative analysis of the smoothing effect between the conventional moving average method and a new method based on frequency response analysis.

수력발전소 물 공급 설비에 대한 FTA 모형 (FTA Modeling of Water Supply System for Hydro-power Plant)

  • 전태보;권창섭
    • 산업기술연구
    • /
    • 제26권B호
    • /
    • pp.145-155
    • /
    • 2006
  • High level of reliability in facility operation is specifically required these days. The goal of this study is to secure a methodology for reliability analysis of hydro-power plant so that an appropriate decision for operation and investment can be made. Fault tree analysis of water supply system within hydro-power plant has been performed in this study. We briefly examined the electric power generation facility and water supply system. We then developed fault tree for the water supply system based on failure modes and effects analysis. We conclude this study and provided future research areas.

  • PDF