• Title/Summary/Keyword: Power Supply System

검색결과 3,259건 처리시간 0.031초

실린더 페라이트 코어를 사용한 무접점 전력 변환 시스템 (A Contactless Power Conversion System Use a Slinder Ferrite Core)

  • 이승준;안재우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.638-641
    • /
    • 2001
  • Connectorless power transmission and supply are the power transfer device revealed by resonant inverter or transformer using inductant device. Recently, on power supply have been going on frequently, so several power supply circuit forms are announced. But Compared with the circuit of previous paper, instead of the circuit composed of a simple sylinder Ferrit, I was manufacture in a sylinder that It was a double overlab to a sylinder and I was followed a double flux in inner flux path. Above all, for practicalization, supply circuit operation character analysis and development of controller should be preceded. According to this paper, power transmission and supply analyze characters and design control circuit like the analysis of general resonant inverter for power transmission. They compose the circuit to get sinusoid wave output voltage using pulse width modulation control mode. For Supply, output wave form through power track and power pick-up of magnetic inductance includes ripper component. So I intend to design the controller including filter and regulator, compare analyze theoretical result with real measurement value and then show you their practicality

  • PDF

수용가 직류 서비스를 위한 무접점 전원장치 (Contactless Power Supply for DC Power Service in Hybrid Home Generation System)

  • 정봉근;강성인;김윤호;김은수
    • 전력전자학회논문지
    • /
    • 제12권2호
    • /
    • pp.174-182
    • /
    • 2007
  • 신재생에너지 중에서 태양광 에너지가 중요 에너지원으로서 각광받고 있고 적용이 증대되고 있다. 특히, 미래에는 하이브리드 태양광 발전 시스템이 독립 분산 전원 시스템으로 널리 사용될 것으로 예상되고 있다. 본 논문에서는 DC전력을 기계적인 접촉에 의해 전달하는 것보다는 마그네틱 커플링에 의해 비접촉으로 에너지를 전달 할 수 있는 무접점전원장치를 사용한 직류수용가 서비스 태양광발전시스템을 제안하였다. 제안 적용된 무접점 전원장치는 무접점 변압기와 Half-bridge LLC 공진컨버터, 영 전압 스위칭 Boost컨버터로 구성되어 있다.

고효율 무전극형광등용 전원장치의 평가기준 및 신뢰성향상 연구 (A Study of assessment criteria and reliability improvement for power supply of electrodeless fluorescent lamp)

  • 함증걸;신종욱
    • 조명전기설비학회논문지
    • /
    • 제17권2호
    • /
    • pp.34-40
    • /
    • 2003
  • 본 논문에서는 무전극형광등용 전원장치에 대한 전기적 및 광학적특성을 알아보기 위하여 성능측정을 수행하였으며, 무전극 형광램프의 고 수명에 대한 전원장치의 이론적인 평균고장수명을 알아보기 위하여 MIL-HDBK-217방법에 의한 예측방법을 이용하여 전원장치의 주위온도, 사용장소 및 설치조건에 따라 각 온도별로 각부품의 고장율을 예측하여 평균고장수명을 예측하였다. 그 결과 무전극형광등은 온도가 어느 정도가 유지되어야 광 효율이 좋은 반면 전원장치는 온도가 높으면 상대적으로 수명이 급격히 줄어들면서 특성이 열화하는 경항을 가진다.

광범위 입력전압을 갖는 준공진형 플라이백 파워서플라이의 연구 (A Study of Quasi-Resonant Flyback Power Supply with Very Wide Input Voltage)

  • 이용근;나재두
    • 전기학회논문지P
    • /
    • 제64권3호
    • /
    • pp.143-145
    • /
    • 2015
  • One of the many problems besetting the converter designer is being able to design a switching power supply that can operate in the range of very wide input voltage. Specially, in an emergency diesel generator system, the AVR(Automatic Voltage Regulator) is a regulator which regulates the output voltage of the generator at a nominal constant voltage level. In addition, the AVR must be operated in very wide input voltage. Therefore, a power supply for the AVR must be operated at the very wide input voltage range. In this paper, a quasi-resonant flyback power supply with very wide input voltage range is proposed. Also, the performance of the proposed power supply is demonstrated through experiments.

건축물의 비상전원 적용실태 및 자가발전설비의 안전 운전 모델에 관한 연구 (Analysis on Emergency Power Supplies in Buildings and a Model for Safe Operation of the Emergency Power System)

  • 이원강;최충석
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.49-56
    • /
    • 2012
  • The purpose of this paper is to present a model for operating an emergency power system(EPS) that can secure a sufficient power supply used in case of a fire by analyzing the status of power supplies for emergency and firefighting operations. Investigations on the one of the causes of the operational failure of firefighting systems show evidence of EPS. Generally, when power to a building is interrupted, EPS supplies the emergency load(excepted firefighting load) first. When a power outage and a fire occur simultaneously, the EPS must be able to supply both the emergency load and the firefighting load, especially the firefighting load to the end. However, in order to save construction costs, emergency power generators in apartment, commercial, and business buildings can satisfy only one of the required loads. In cases like this, when a power outage and a fire occur simultaneously, there is a danger of firefighting equipment not operating due to insufficient power supply from the emergency generator. Therefore, an EPS must have a reserved firefighting power that can supply both the firefighting and the emergency load. Such EPS, when faced with a danger of an overload, will shut down the supply to all or part of the emergency load, thus securing a continuous power supply to the firefighting equipment. The generator power system with reserved firefighting power (RFP) will also have an indicator to show that the selective control is being used. General power generation systems for emergency load and firefighting load were found to have a demand factor of 50-60% with a lump. However, when installing an EPS, the builders must choose the higher demand factor suggested according to the official approval demand factor of the building.

전기철도의 DC급전시스템 시뮬레이터 (Simulator for DC Power Supply System in Electric Railway)

  • 정상기;홍재승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.720-726
    • /
    • 2000
  • The advance of traction motor control technology and the complexity of the traction power supply system makes the simulation essential in determining the dimension of the traction power supply system. The conventional method, use of the simplified and/or empirical equations, becomes inadequate in optimization of the design. The simulator presented in this paper is a numerical time based simulator running on a PC. The input to the simulator includes the track data, the train characteristic, network data and operating data. Basically the simulator conducts train running simulation and loadflow study repeatedly. The principle algorithms and its output is discussed in the paper.

  • PDF

교류 급전시스템 해석을 위한 윈도우즈 기반 시뮬레이터 개발 (Development of Simulator for AC Traction Power Supply System)

  • 김주락;이장무;창상훈;김정훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.411-417
    • /
    • 2009
  • This paper describes the development of integrated simulator for traction power supply system with GUI (Graphic User Interface). This simulator consists of a lot of calculation modules such as TPS, time table, line constant, and power supply system analysis. Each module has input and output structure respectively. The proposed simulator is tested on both high speed railway line and metropolitan subway line. The test has confirmed the function of the developed simulator.

  • PDF

모듈형 파워 서플라이를 이용한 철도 신호용 전원장치 (A Railway signal power supply system using the module type power supply)

  • 노성채;이유경;김수홍
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.836-842
    • /
    • 2005
  • This paper presents a power supply of railway signal system using a Z-source inverter. The Z-source inverter overcomes the conceptual and theoretical barriers and limitations of the tradition voltage-source inverter and current-source inverter and provides novel power conversion concept. The Z-source inverter is a Buck-Boost inverter that has a wide range of obtainable voltage.

  • PDF

Design of a renewable energy system with battery and power-to-methanol unit

  • Andika, Riezqa;Kim, Young;Yun, Choa Mun;Yoon, Seok Ho;Lee, Moonyong
    • Korean Journal of Chemical Engineering
    • /
    • 제36권1호
    • /
    • pp.12-20
    • /
    • 2019
  • An energy storage system consisting of a battery and a power-to-methanol (PtM) unit was investigated to develop an energy storage system for renewable energy systems. A nonlinear programming model was established to optimize the energy storage system. The optimal installation capacities of the battery and power-to-methanol units were determined to minimize the cost of the energy system. The cost from a renewable energy system was assessed for four configurations, with or without energy storage units, of the battery and the power-to-methanol unit. The proposed model was applied to the modified electricity supply and demand based on published data. The results show that value-adding units, such as PtM, need be included to build a stable renewable energy system. This work will significantly contribute to the advancement of electricity supply and demand management and to the establishment of a nationwide policy for renewable energy storage.

디젤발전기 엔진 상태 진단 기술의 발전소 적용 연구 (A Study on the Power Plant Application of Engine Condition Diagnosis Technology for Diesel Generator)

  • 최광희;이상국
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.17-22
    • /
    • 2013
  • Diesel generator of nuclear power plant has a role for supply of emergency electric power to protect reactor core system in event of loss of off-site power supply. Therefore diesel generator should be tested periodically to verify the function that can supply specified frequency and voltage at design power level within limited time. For this purpose, appropriate maintenances in case that abnormal conditions were found are required in allowed time. In this paper, results of development of engine condition diagnosis technology and study on power plant of its technology for diesel generator are described.