• Title/Summary/Keyword: Power Standards

Search Result 1,242, Processing Time 0.026 seconds

A New Single-Stage PFC AC/DC Converter

  • Lee, Byoung-Hee;Kim, Chong-Eun;Park, Ki-Bum;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.238-240
    • /
    • 2007
  • A new ZVZCS Single-Stage Power-Factor-Correction(PFC) AC/DC converter with boost PFC cell is integrated with voltage doubler rectified asymmetrical half-bridge(VDRAHB) is proposed in this paper. The proposed converter features good power factor correction, low current harmonic distortions, tight output regulations and low voltage of link capacitor. An 85W prototype was implemented to show that it meets the harmonic requirements and standards satisfactorily with nearly unity power factor and high efficiency over universal input.

  • PDF

Comparison and Calculation Method on the Separation Between ICT and Power Cabling Considering EMC (EMC를 고려한 ICT배선과 전력배선 이격거리 기준의 비교검토 및 산정방식)

  • Yeom, Jin-Geun;Jeong, Seung-Hyun;Byeon, Cheol-Gyun;Lee, Ju-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.91-96
    • /
    • 2014
  • The requirements for separation between ICT cables and power cables depend upon the electromagnetic immunity of the ICT cable, the construction of the power cable, the quantity of, and type of electrical circuits and the presence of dividers etc. We studied and reviewed the regulations and standards relevant for requirements of this separation in domestic and foreign. And then we would like to suggest the method of separation calculation between ICT and power cabling taking the EMC into consideration.

Design and Implementation of Pre.In-Service Inspection Management System for Nuclear Power Plants (원전 가동전.중 점검관리시스템 설계 및 구현)

  • Shin, Jin-Ho;Yi, Bong-Jae;Song, Jae-Ju
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.04b
    • /
    • pp.1207-1210
    • /
    • 2002
  • 장기간의 원자력발전소 운영과정에서 가동전 중검사는 설비의 건전성을 확인하는 매우 중요한 점검과정이다. 가동전 중검사 결과 많은 양의 검사데이터가 생산되며 이러한 검사데이터는 과거 검사결과와 비교하여 결함지시의 성장여부 등이 검토될 수 있어야 하며 후속 검사를 위한 기초 데이터로 활용될 수 있어야 한다. 또한 검사에 사용되는 검사장비, 검사자, 검사절차서, 관련 도면, Codes & Standards 등 검사자원의 체계적인 관리가 필요하며 이를 위한 정보시스템의 지원이 필수적이다. 또한 수작업으로 작성되는 가동전 중검사계획(LTP 등) 작성업무의 자동화가 필요하며, 검사계약이 경쟁체제로 전환됨에 따라 검사업체의 변경 여부에 관계없이 검사결과의 연속성이 유지되어야 하며 검사절차나 양식 등의 표준화가 필요하다. 본 논문에서는 이러한 현안사항을 개선할 수 있는 데이터베이스 응용시스템을 설계 및 구현하고 그 개발 과정을 소개한다.

  • PDF

Efficiency appraisal of 22.9kV tree retardant power cable (22.9kV 트리억제형 전력케이블의 성능평가)

  • Kim, We-Young;Yun, Dae-Hyuk;Park, Tae-Gone
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.179-182
    • /
    • 2002
  • XLPE compound have used for insulation of 22.9(kV) power cable. But tree retardant power cable has developed and is going to br used commonly. TR XLPE compound retard production and growth of water tree. In this paper, tensile strength, elongation at break, degree of crosslinking, lightning impulse test, AC breakdown test, cyclic aging for 14days and accelerated water treeing test of TR XLPE insulated power cable were examined according to the KEPCO buying spec. & AEIC CS 5-94 standards. before and after As the result, tensile strength, elongation at break and degree of crosslinking test results of TR XLPE insulation were higher than requirement values. After accelerated water treeing test for 120 days, 240 days and 360 days, AC breakdown voltages were not decreased for accelerated water treeing aging duration

  • PDF

Single-Stage High Power Factor TTFC(Two-Transistor Forward Converter) (단일전력단 고역률 TTFC(Two-Transistor Forward Converter))

  • Bae, Jin-Yong;Kim, Yong;Kim, Pill-Soo;Lee, Eun-Young;Kwon, Soon-Do
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.226-228
    • /
    • 2005
  • This paper presents the single-stage High Power Factor TTFC(Two-Transistor Forward Converter). Recently, due to growing concern about the harmonic pollution of power distribution systems and the adoption of standards such as ICE 61000-3-2 and IEEE 519, There is a need to reduce the harmonic contests of AC line currents of power supplies. This research proposed the single-stage two switch forward circuit for low voltage and high current output.

  • PDF

Anomaly Detection System for Solar Power Distribution Panels utilizing Thermal Images

  • Kwang-Seong Shin;Jong-Chan Kim;Seong-Yoon Shin
    • Journal of information and communication convergence engineering
    • /
    • v.22 no.2
    • /
    • pp.159-164
    • /
    • 2024
  • This study aimed to develop an advanced anomaly-detection system tailored for solar power distribution panels using thermal imaging cameras to ensure operational stability. It addresses the imperative shift toward digitalized safety management in electrical facilities, transcending the limitations of conventional empirical methodologies. Our proposed system leverages a faster R-CNN-based artificial intelligence model optimized through meticulous hyperparameter tuning to efficiently detect anomalies in distribution panels. Through comprehensive experimentation, we validated the efficacy of the system in accurately identifying anomalies, thereby propelling safety protocols forward during the fourth industrial revolution. This study signifies a significant stride toward fortifying the integrity and resilience of solar power distribution systems, which is pivotal for adapting to emerging technological paradigms and evolving safety standards in the energy sector. These findings offer valuable insights for enhancing the reliability and efficiency of safety management practices and fostering a safer and more sustainable energy landscape.

Standard Field Generation Using a Micro-TEM Cell and Its Measurement Uncertainty Evaluation (Micro-TEM Cell을 사용한 표준 전자기장의 발생 및 측정불확도 평가)

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Kang, Ung-Taek;Kang, No-Weon;Kang, Tae-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.1
    • /
    • pp.91-99
    • /
    • 2009
  • In this paper, a standard field generation method using a micro-TEM ceil is described and its measurement uncertainty is evaluated. The standard field generation system consists of an auto-leveling signal source, a micro-TEM cell operating up to 1.2 GHz, and a power measuring Instrument using a thermistor mount. Measurement results of a field strength key comparison (CCEM.RF-K20) for the field strength of 20 V/m at frequencies between 10 MHz and 1 GHz are presented for validating the standard field generation method.

A Trend of the National and International Standards for LCD Backlights (LCD 백라이트 국내외 표준화 동향)

  • Cho, M.R.;Shin, S.W.;Lee, S.H.;Hwang, M.K.;Lee, D.Y.;Yang, S.Y.;Ham, J.K.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.141-144
    • /
    • 2007
  • BLUs are major component in LCD industry which occupies 90% or more of FPD market worldwide and BLU market is expected to be expanded continuously according to the trend of miniaturization, slimness, low power consumption and low weight. The larger the BLU market scale, the more important standardization of performance evaluation techniques to clearly prescribe the product specification. Currently the government is promoting the establishment of related laws and coincidence with international standards to cope with agreements such as WTO/TBT, but the nongovernmental standardization activities are not enough to be actualized. Furthermore, BLU related components such as CCFL, EEFL, inverter and reflector are already developed for localization to substitute imports with home products but collective standardization, national standardization, and international standardization are still not done. So, performance specifications and evaluation methods for normal fluorescent lamps or industrial lamps are being adopted and used as national standards and safety certification standards instead. Making these standards enables to prepare a chance to penetrate into global market and to promote world best products. Also, by making this collective standard, it provides chances to take part in international standardization activities, to protect domestic industries and technologies, to obtain the trend of advanced technologies, and to be predominant over other countries. That is to say, CCFL standardization helps raise 21st century national strategic technology policy and go ahead of globalization of core technologies.

  • PDF

A Study on EDH Methods of Major Standardization Bodies and Architecture of Advanced Standards Information System (주요 표준화기구의 EDH (Electronic Document Handling) 방법 분석 및 차세대 표준정보유통망의 운용구조에 관한 연구)

  • Koo, Kyoung-Cheol;Sohn, Hong;Park, Ki-Shik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.67-73
    • /
    • 2000
  • In an era of very rapid technological change, standardization organizations have been confronted with the problem that they should develop more new and more complex standards as strategic tools for enforcement of competitive power in shorter time according to the reduction of Life Cycle of products and the increase in the number of standards and their complexity. To cope with this challenge, worldwide Standardization Bodies now implement and operate their own EDH (Electronic Document Handling) system which is electronic means applied to development and delivery of standards based on their standardization workflow. In this paper, we analyze the EDH guidelines and methods of major Standardization Bodies, International bodies such as ITU-T, ISO/IEC JTC1, Regional bodies such as ETSI, Committee T1 of USA and TTA (Telecommunications Technology Association) of Korea. Finally, we discuss future EDH policy and suggest architecture of Advanced Standards Information System.

  • PDF

Development of an Accident Consequence Assessment Code for Evaluating Site Suitability of Light- and Heavy-water Reactors Based on the Korean Technical Standards

  • Hwang, Won Tae;Jeong, Hae Sun;Jeong, Hyo Joon;Kil, A Reum;Kim, Eun Han;Han, Moon Hee
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.368-372
    • /
    • 2016
  • Background: Methodologies for a series of radiological consequence assessments show a distinctive difference according to the design principles of the original nuclear suppliers and their technical standards to be imposed. This is due to the uncertainties of the accidental source term, radionuclide behavior in the environment, and subsequent radiological dose. Both types of PWR and PHWR are operated in Korea. However, technical standards for evaluating atmospheric dispersion have been enacted based on the U.S. NRC's positions regardless of the reactor types. For this reason, it might cause a controversy between the licensor and licensee of a nuclear power plant. Materials and Methods: It was modelled under the framework of the NRC Regulatory Guide 1.145 for light-water reactors, reflecting the features of heavy-water reactors as specified in the Canadian National Standard and the modelling features in MACCS2, such as atmospheric diffusion coefficient, ground deposition, surface roughness, radioactive plume depletion, and exposure from ground deposition. Results and Discussion: An integrated accident consequence assessment code, ACCESS (Accident Consequence Assessment Code for Evaluating Site Suitability), was developed by taking into account the unique regulatory positions for reactor types under the framework of the current Korean technical standards. Field tracer experiments and hand calculations have been carried out for validation and verification of the models. Conclusion: The modelling approaches of ACCESS and its features are introduced, and its applicative results for a hypothetical accidental scenario are comprehensively discussed. In an applicative study, the predicted results by the light-water reactor assessment model were higher than those by other models in terms of total doses.