• Title/Summary/Keyword: Power Standards

Search Result 1,242, Processing Time 0.03 seconds

Research on Application of Functional Safety for Developing Combat Hybrid Electric Vehicles (하이브리드 전투차량의 기능안전성 적용 연구)

  • Chang, Kyogun;Lee, Yoon Bok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.543-549
    • /
    • 2012
  • Hybrid electric propulsion systems are expected as future primary combat platforms because the systems can supply enough electric power, easily locate components inside vehicles, and maneuver without undesired noise. However, increasing electric/electronic/software usage causes abnormal failure patterns which have not been noticeable in conventional automotive. Recently, the functional safety standard for road vehicles were enacted and vehicle manufacturers request their components which satisfy standardized quality. This research analyzes functional safety standards(IEC 61508 and ISO 26262) and compares the standards for road vehicles with military standards of system safety. Strategies to apply functional safety in the combat hybrid electric vehicle are scrutinized.

DC Appliance Safety Standards Guideline through Comparative Analysis of AC and DC Supplied Home Appliances

  • Ahn, Jung-Hoon;Kim, Dong-Hee;Lee, Byoung-Kuk;Jin, Hyun-Cheol;Shim, Jae-Sun
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.51-57
    • /
    • 2012
  • This paper provides a safety guideline for DC supplied home appliances through the comparative analysis of existing safety guideline for AC supplied home appliances. For this purpose, a predictive DC home appliance model is suggested and in special international safety standards of AC appliances are also analyzed. Moreover, a DC distribution system is built to verify the validity of the proposed safety guideline. The detailed analyzing process is explained with help of informative experimental results.

Trend of Industry and Standard related to Offshore Cable for Offshore Wind Farm (해상풍력용 해저케이블 산업 및 기술기준 동향)

  • Kim, Kyung-Hwa;Song, Yong-Un;Kim, Mi-Young;Kim, Mann-Eung
    • Journal of Wind Energy
    • /
    • v.3 no.2
    • /
    • pp.11-17
    • /
    • 2012
  • An offshore(submarine) cable has been used for more than a century, however it has been used mainly for communication or power supply to near-shore island. Therefore, offshore cable has not been got more attention than other types of cable and the related standards have also not been established well. However wind farms have been shifting from land to offshore because of better wind condition. Consequently, it has been pushing up demand for offshore cable. Hence, this paper introduces the trend of offshore cable industry and related standards or recommendations only focusing on offshore wind farm. In details, the installed offshore cables in offshore wind farms, the main offshore cable makers and up to date technologies are covered. In addition, the related standards or recommendations are also analyzed and compared each other.

An Integrative Review on Domestic Site Release Criteria of Nuclear Power Plant based on the Analysis of Foreign Site Release Criteria (국외 부지해제기준 분석을 통한 국내 원자력발전소 부지해제기준 도출에 관한 고찰)

  • Bae, YuJung;Kim, Yongmin;Ahn, Seokyoung;Kim, Cheol Min
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.269-277
    • /
    • 2015
  • In recent years, concern about the decommissioning of nuclear power plants has been growing according to the nuclear power plants aging. Although site reuse is one of the most important issues in doing decommissioning of nuclear power plants in view of the internal affairs, there is currently no specific standard of the site release criteria for site reuse in the Republic of Korea. In this study, we analyzed the international safety standards for the site release(IAEA's Safety Guide No. WS-G-5.1) and the present domestic condition. Also, we studied the site release criteria and real life examples about advanced countries such as United states and Europe, which already have experience of decommissioning or site release. As a results of the study, we suggested proper standards and future consideration to establish site release criteria. This will be used for preliminary data for establishing the domestic site release criteria after the decommissioning of nuclear power plants.

A Study on Performance Improvement of Non-Profiling Based Power Analysis Attack against CRYSTALS-Dilithium (CRYSTALS-Dilithium 대상 비프로파일링 기반 전력 분석 공격 성능 개선 연구)

  • Sechang Jang;Minjong Lee;Hyoju Kang;Jaecheol Ha
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.33 no.1
    • /
    • pp.33-43
    • /
    • 2023
  • The National Institute of Standards and Technology (NIST), which is working on the Post-Quantum Cryptography (PQC) standardization project, announced four algorithms that have been finalized for standardization. In this paper, we demonstrate through experiments that private keys can be exposed by Correlation Power Analysis (CPA) and Differential Deep Learning Analysis (DDLA) attacks on polynomial coefficient-wise multiplication algorithms that operate in the process of generating signatures using CRYSTALS-Dilithium algorithm. As a result of the experiment on ARM-Cortex-M4, we succeeded in recovering the private key coefficient using CPA or DDLA attacks. In particular, when StandardScaler preprocessing and continuous wavelet transform applied power traces were used in the DDLA attack, the minimum number of power traces required for attacks is reduced and the Normalized Maximum Margines (NMM) value increased by about 3 times. Conseqently, the proposed methods significantly improves the attack performance.

Improved Power Quality IHQRR-BIFRED Converter Fed BLDC Motor Drive

  • Singh, Bhim;Bist, Vashist
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.256-263
    • /
    • 2013
  • This paper presents an IHQRR (Integrated High Quality Rectifier Regulator) BIFRED (Boost Integrated Flyback Rectifier Energy Storage DC-DC) converter fed BLDC (Brushless DC) motor drive. A reduced sensor topology is derived by utilizing a BIFRED converter to operate in a dual DCM (Discontinuous Conduction Mode) thus utilizing a voltage follower approach for the PFC (Power Factor Correction) and voltage control. A new approach for speed control is proposed using a single voltage sensor. The speed of the BLDC motor drive is controlled by varying the DC link voltage of the front end converter. Moreover, fundamental frequency switching of the VSI's (Voltage Source Inverter) switches is used for the electronic commutation of the BLDC motor which reduces the switching losses in the VSI. The proposed drive is designed for a wide range of speed control with an improved power quality at the AC mains which falls within the recommended limits imposed by international power quality standards such as IEC 61000-3-2.

The Electric Power System Remote Control Of Semiconductor Plasma Manufacturing Equipment Using Power Line Communication (Power Line Communication을 이용한 반도체 Plasma 장비 전력시스템 원격제어)

  • Lee, Nae-Il;Kim, Jin-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1678-1679
    • /
    • 2007
  • This paper is the electric power system remote control of semiconductor plasma manufacturing equipment using PLC(power line communication). PLC is useful for economical data link but various problems and limitations are caused in using power lines for communications channel Develop of Semiconductor plasma manufactur ing equipment and remote automation technologies of tool develops day after day and standards. Also, Remote electric power control and device module control by GUIRCS(Graphic User Interface Remote Control System) of tool are monitoring in real time.

  • PDF

STATCOM Helps to Guarantee a Stable System

  • Andersen, B.R;Gemmell, B.D.;Horwill, C.;Hanson, D.J.
    • Journal of Power Electronics
    • /
    • v.1 no.2
    • /
    • pp.65-70
    • /
    • 2001
  • Transmission System Operators are governed by operational security standards that are applied in real time. During system disturbances, the System Operators must rely on the installed protection and control equipment, prior to human intervention. New power electronic solutions bring rapid and repeatable responses to disturbances, which will help System Operators to guarantee a stable system. Last year, Alstom completed the world's first competitively bid STATCOM to support the voltage on National Grid's 400kV network that supplies London and the Southeast from the north of the UK. It is rated ${\pm}75MVAr$ and forms part of a Static Var System (SVS) with a total rating of 0 to 225MVAr. This paper will describe the reasons for its size, location, its chain-link configuration and give examples of its operating performance. The paper will also describe the features that allow this STATCOM to deliver much more than reactive compensation in support of a wider transmission service objective, as system conditions require.

  • PDF

Integrated 3-Channel Flux-Locked-Loop Electronics for the Readout of High-$T_c$ SQUID (고온초전도 SQUID 신호 검출을 위한 3채널용 FLL 회로)

  • 김진목;김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.55-60
    • /
    • 2003
  • We designed and constructed integrated 3-channel flux-locked-loop (FLL) electronic system for the control and readout of high-T$_{c}$ SQUIDs. This system consists of low noise preamplifiers, integrators, interface circuits, and software. FLL operation was carried out with biased signals of 19 KHz modulated current and 150 KHz modulated flux, which are reconstructed as detected signals by preamplifier and demodulator. Computer controlled interface circuits regulate FLL circuit and adjust SQUID parameters to the optimum operating condition. The software regulates interface circuits to make an auto-tuning for the control of SQUIDs, and displays readout data from FLL circuit. 3-channel SQUID electronic system was assembled with 3 FLL-interface circuit boards and a power supply board in the aluminum case of 56 mm ${\times}$ 53 mm${\times}$ 150 mm. Overall noise of the system was around 150 fT/(equation omitted)Hz when measured in the shielded room, 200 fT/(equation omitted)Hz in a weakly shielded room, respectively.y.

  • PDF

Astigmatically compensated cw Ti:Sapphire laser pumped by $Ar^+$ laser (비점수차가 보상된 $Ar^+$ 레이저로 펌핑하는 cw Ti:Sapphire 레이저)

  • Yoon, Tai-Hyun;Kim, Gyu-Ug;Jo, Jae-Heung;Won, Jong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.451-454
    • /
    • 1990
  • Room temperature cw operations of a standing wave and a unidirectional Ti:Sapphire laser pumped by a $Ar^+$ laser have been demonstrated in the same pumping cavity configuration. Laser emission at 790 nm was excited with all-line $Ar^+$ laser pump for both cavities. The maximum output power was found to be 600 mW in the standing wave cavity and 210 mW in the ring cavity. Values of (83 ${\pm}$ 10) % for the internal quantum efficiency and (3.0 ${\pm}$ 0.5) % for the round-trip cavity loss for standing wave cavity are obtained from the thresholds and slope efficiencies measured with 2.4 and 11.2 % optput couplers. The measured cavity-loss value at 790 nm gives a meterial figure of merit (FOM) to be 146. Unidirectional operation of the ring Ti:Sapphire laser will be discussed.

  • PDF