• Title/Summary/Keyword: Power Saving Control

Search Result 407, Processing Time 0.031 seconds

A Novel Module Control Technology for High-Power LED Backlight

  • Su, Chun-Wei;Chiang, Chin-I;Li, Tzung-Yang;Tsou, Chien-Lung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1326-1329
    • /
    • 2009
  • In large-area LCD displays, we have developed two new control technologies for high-power LED backlight. The Novel control technology called scanning control and local gray control. In addition, a conceptual display system power management was developed. We have implemented high power-LED module driving system which can achieve power saving and cost down. Finally, we designed LED light-bar module of the side type as a backlight source. It not only achieved light & thin but also reduced the quantity of LEDs.

  • PDF

Energy Efficient Cross Layer Multipath Routing for Image Delivery in Wireless Sensor Networks

  • Rao, Santhosha;Shama, Kumara;Rao, Pavan Kumar
    • Journal of Information Processing Systems
    • /
    • v.14 no.6
    • /
    • pp.1347-1360
    • /
    • 2018
  • Owing to limited energy in wireless devices power saving is very critical to prolong the lifetime of the networks. In this regard, we designed a cross-layer optimization mechanism based on power control in which source node broadcasts a Route Request Packet (RREQ) containing information such as node id, image size, end to end bit error rate (BER) and residual battery energy to its neighbor nodes to initiate a multimedia session. Each intermediate node appends its remaining battery energy, link gain, node id and average noise power to the RREQ packet. Upon receiving the RREQ packets, the sink node finds node disjoint paths and calculates the optimal power vectors for each disjoint path using cross layer optimization algorithm. Sink based cross-layer maximal minimal residual energy (MMRE) algorithm finds the number of image packets that can be sent on each path and sends the Route Reply Packet (RREP) to the source on each disjoint path which contains the information such as optimal power vector, remaining battery energy vector and number of packets that can be sent on the path by the source. Simulation results indicate that considerable energy saving can be accomplished with the proposed cross layer power control algorithm.

Neural Network Based On-Line Efficiency Optimization Control of a VVVF-Induction Motor Drive (인공신경망을 이용한 VVVF-유도전동기 시스템의 실시간 운전효율 최적제어)

  • Lee, Seung-Chul;Choy, Ick;Kwon, Soon-Hak;Choi, Ju-Yeop;Song, Joong-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.166-174
    • /
    • 1999
  • On-line efficiency optimization control of an induction motor drive using neural network is important from the v viewpoints of energy saving and controlling a nonlinear system whose charact81istics are not fully known. This paper p presents a neural networklongleftarrowbased on-line efficiency optimization control for an induction motor drive, which adopts an optimal slip an밍J.lar frequency control. In the proposed scheme, a neuro-controller provides minimal loss operating point i in the whole range of the measured input power. Both simulation and experimental results show that a considerable e energy saving is achieved compared with the conventional constant vlf ratio operation.

  • PDF

A Study on the Development of Power Control Wireless Interface Module for Demand_Response using IEEE1451.5 (IEEE1451.5 기반의 전원 제어용 무선 DR_인터페이스 장치 개발에 관한 연구)

  • Lee, Joung-Han;Choi, In-Ho;Ryu, Joong-Kyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.12
    • /
    • pp.1192-1196
    • /
    • 2009
  • Recently, the environment contamination problem and energy saving are the social issues. So, the Green IT based Smart Grid was suggested. The smart grid will let rates fluctuate even more dynamically, depending on conditions using energy. Thus, green IT includes the dimensions of environmental sustainability and the economics of energy efficiency. The smart controller in which it is controlled by DR in order to manage the energy consumption by using AMI is needed in order to apply its technology to the real life. In this paper, DR_WTIM of the IEEE1451.5 base which has the DR function for connecting to AMI of the wireless base is developed. By using this apparatus for the power control system, the energy saving effect is shown. Moreover, by using the IEEE1451.5 technology, the problem of energy consumption is solved in order to apply to power controller designed for efficient use energy.

A Proposal of a Power Saving Hydraulic Unit and Controller Design (동력 절약형 유압유니트 제안 및 제어기 설계)

  • Yum, Man-Oh;Lee, Sang-Yun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.1
    • /
    • pp.80-88
    • /
    • 2010
  • In a conventional system, hydraulic unit pumps out pressurized oil when the power use is not even necessary. As a result, it causes much power loss. This study is on the proposal of new hydraulic unit which controls the revolution of the pump in order to produce proper power needed and to have good response characteristic. In addition, the existing control methods such as PID control method, fuzzy control method, and adaptive control method are applied to the proposed hydraulic unit. Then the best control method is selected and the controller is developed to realize minimum power loss.

Thermal Environment Analysis of a Classroom by CFD Simulation to Determine Optimal Temperature Sensor Position in Ceiling Type Air-Conditioning System (천정형 에어컨 온도센서의 최적 위치 결정을 위한 교실의 CFD 열환경 분석)

  • Li, M.H.;Kim, D.G.;Kum, J.S.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.43-49
    • /
    • 2006
  • Nowadays, the thermal environments of classrooms are usually adjusted by the ceiling type air-conditioning system with a temperature sensor installed on inlet of an air-conditioner. However, it is not clear that the conventional temperature sensor position is proper to satisfy both thermal comport and energy saving in summer especially. Therefore, this study is aimed at finding out the best position of the temperature sensor on the purpose of the comfort thermal environment and energy saving. The different 5 positions for the temperature sensor are supposed in this paper to analyze thermal environment by CFD. From the analysis through the CFD simulations, the best position of the temperature sensor satisfying for both comfort thermal environment and energy saving is obtained.

  • PDF

Demand Control Application Strategies for Saving Electric Power Price of Central Cooling System (중앙 냉방시스템의 전력량 요금절감을 위한 디맨드제어 적용방안 연구)

  • Hwang, Jin-Won;Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.4
    • /
    • pp.1-7
    • /
    • 2012
  • In this study, computer simulation for demand control strategies to save the electric energy and power price in the building central cooling system is done. The demand control and outdoor reset control algorithms are applied by consideration the electric energy and power price according to the energy consumption characteristics. The suggested control methods show better responses in the power price and energy consumption in comparison with the conventional one.

An active system for unnecessary noise reduction in kitchen range hoods

  • Kim, Eunhee;Jang, Jaechun;Lim, Changmok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.3
    • /
    • pp.91-96
    • /
    • 2016
  • We have surrounded undesired living noises in our life. One of biggest noises coming out of range hood during cooking in the kitchen. A range hood is one of the most important appliances in the kitchen because it ventilates polluted air out during cooking, and maintains air quality in the kitchen. But current kitchen range hoods bring up some issues; First, the range hoods consume massive amount of standby power not in use condition. Second, current models have designed manual fan operating system with sudden onset of noise with starting. In this paper, we propose an auto control system entire processes from air ventilation to noise reduction. Our system is consist of three parts (Eco-sensors pack, Main Controller and Active Noise Controller); Eco-sensors pack detects air pollution of kitchen areas and sends the detection values to Main Controller. Main Controller determines operation of range hood by detected values. Active Noise Controller is located inside of the range hood. It received starting signals from Main Controller which elicits degrees of polluted air condition and fan operating speed from 1 to 3. Once Active Noise Controller detected the signals, it runs a ventilating fan until new value from Main Controller becomes 0. while the range hood works, A noise cancellation algorithm inside of Active Noise Controller become activated to reduce levels of noise. As a result, the proposed system clearly shows reduction in power consumption include standby power and decreases in levels of noise.

A Study on the Energy Saving Method by controlling Capacity of Sea Water Pump in Central Cooling System for Vessel (선박용 중앙냉각시스템의 해수 펌프 용량조절에 따른 에너지 절감 기법에 관한 연구)

  • Lee, Ji-Young;Yoo, Heui-Han;Kim, Yun-Hyung;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.592-598
    • /
    • 2007
  • The fuel charge is getting higher in navigation cost. Therefore, shipowners try to find the method for reducing oil consumption. ESS(Energy Saving System) is one of he method. ESS is the system consisted with two inverters, ESS control unit and monitoring system. Two inverters control two main sea water cooling pumps. In the ESS control Unit, the control algorithm finds optimized point to decrease a power consumption of main sea water cooling pumps. Monitoring system observes ESS not to work improperly. ESS is experimented in the laboratory with real condition and analyzed in every view. After experiment, the result of the experiment shows that the control algorithm works correctly and safely. ESS has a plan to be operated in the ship soon. In that case, additional devices are needed to connect ESS with cooling system of the vessel. So the development of addition device is needed and being studied.

International Standardization and Implementation of Home Energy Saving System for Smart Grid (스마트 그리드를 위한 홈 에너지 절감 시스템의 IEC 국제표준화 및 구현)

  • Choi, Kwang-Soon;Lee, Sang-Won;Park, Young-Choong;Jung, Kwang-Mo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.12
    • /
    • pp.1222-1229
    • /
    • 2012
  • For the reduction of electric energy consumption and its efficient use at homes or buildings, a new work item proposal for new architecture and functional requirements of Energy Saving System (ESS) was proposed to IEC TC 100 and accepted as a new project, IEC PT 62654 in 2009. Recently, the final ballot for publication passed without negative votes and IEC TS 62654 was finally published in August 2012. For the verification of this standard, Prototype of ESS system composed of an ESS server, ESS clients, and portable ESS terminal were especially implemented in parallel with the standardization. Electric Power Control and Management (EPCM) protocol for the communication between ESS server and clients was also implemented, which supports self-configuration of ESS network, power consumption monitoring, remote power control, and additional functions for intelligent energy saving services.