• Title/Summary/Keyword: Power Saving Control

Search Result 407, Processing Time 0.034 seconds

Performence Characteristics and Analysis Effect of Maximum Power Saving Device in Metal Parts Heat Treatment Company (금속 부품 열처리업체의 최대전력절감장치 동작 특성 및 효과 분석)

  • Chang, Hong-Soon;Han, Young-Sub;Hwang, Ik-Hwan;Seo, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.40-44
    • /
    • 2014
  • In this paper, maximum power is the lowering device using the facility's energy use and peak load electricity through analyzing attitude should like to make it reduce its power base rate. Simulator to manage the demand for power, a maximum electric power base power from electronic watt-hour meters by a device's signal, predictive power, the current power by computing the goal of power for less than Maximum peak power and peak shift, so that you can manage, and peak York, which role you want a cut Metal heat treatment result which analyzes the data, demand for electricity company over the years of analyzing the characteristics of each load, and effects and Reducing power consumption device every month identified seven Sequence control to the load system and successful power control is about showing that the defined goals.

Pulse Density Modulation Controlled Series Load Resonant Zero Current Soft Switching High Frequency Inverter for Induction-Heated Fixing Roller

  • Sugimura, Hisayuki;Kang, Ju-Sung;Saha, Bishwajit;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.226-228
    • /
    • 2006
  • This paper presents the two lossless auxiliary inducors-assisted voltage source type half bridge(single ended push pull:SEPP) series resonant high frequency inverter for induction heated fixing roller in copy and printing machines. The simple high-frequency inverter treated here can completely achieve stable zero current soft switching (ZCS) commutation forwide its output power regulation ranges and load variations under constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operatprinciple is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZCS operation commutation, together with its output effective power regulation charactertics-based on the high frequency PDM strategy. The experimenoperating performances of this voltage source SEPP ZCS-PDM series resonant high frequency inverter using IGBTs are illustrated as compared with computer simulation results and experimenones. Its power losses analysis and actual efficiency are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliimplemented here is proved from the practical point of view.

  • PDF

Energy Saving in Boom Motion of Excavators using IMV (IMV를 사용한 유압굴삭기 붐 동작의 에너지 절감)

  • Huh, Jun Young
    • Journal of Drive and Control
    • /
    • v.14 no.3
    • /
    • pp.1-7
    • /
    • 2017
  • Energy consumption of conventional hydraulic excavators controlled by MCV is considerable when negative load is applied because the meter orifice and meter-out orifice are machined in one spool. Therefore, IMV is introduced to save energy use of hydraulic excavators, but existing hydraulic excavators have various advantages so it is difficult to make a clear comparison. In this study, we compare the use of an existing MCV excavator that has many advantages such as negative control, and IMV for boom up and down operation, and if IMV is used to save energy, we will examine the cause. If possible, for comparability under the same conditions, both systems use pressure balance valves to minimize power consumption when not using power in the actuator. The orifice area at each notch of each valve is calculated, and energy saving is verified by comparing the two systems through simulation.

A Cost Effective Energy Saving of Fluorescent Lighting in Commercial Buildings

  • Lee, Seong-Ryong;Nayar, Chemmangot V.
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.215-222
    • /
    • 2012
  • Lighting represents a significant component of commercial buildings, particularly office buildings. Fluorescent lighting is invariably used in all commercial, industrial and residential areas. A significant amount of lighting energy is wasted every day by leaving the lights on and not utilizing daylight energy. However, if daylight illuminance can be harnessed, this will reduce the electricity consumption of fluorescent lamps and save energy. This paper explains possible significant savings in lighting energy consumption and hence in costs, without reducing the performance and visual satisfaction in office or industrial buildings. It is proposed to obtain energy saving by reducing the supply voltage without degradation in lighting performance. Experimental results confirm that as much as 20% of electrical energy can be saved by reducing about 9% of the supply voltage, without noticeably affecting light output while complying with lighting standard limits.

Development of Hybrid Excavator for Regeneration of Boom Potential Energy (작업장치 위치에너지 회생을 위한 하이브리드 굴삭기 시스템 개발)

  • Yoon, J.I.;Ahn, K.K.;Truong, D.Q.;Kang, J.M.;Kim, J.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.4
    • /
    • pp.1-8
    • /
    • 2009
  • Nowadays with the high fuel prices, the demands for energy saving and green emission of construction machinery have highly been increased without sacrifice of working performance, safety and reliability. The aim of this paper is to propose a new energy saving hybrid excavator system using an electro-hydraulic actuator driven by an electric motor/generator for the regeneration of potential energy. A 5 ton class excavator is analyzed, developed with the boom for the evaluation of the designed system. The hardware implementation is also presented in this paper. A control strategy for the hybrid excavator is proposed to operate the machine with a highest efficiency. The energy saving ability of the proposed excavator is clearly verified through simulation and experimental results in comparison with a conventional hydraulic excavator.

  • PDF

Electric Power Energy Saving and Efficient Measures in Buildings using the Smart-Meter (스마트미터를 활용한 건축물의 전력에너지 절감 및 효율화 방안)

  • Hwang, Hyun Bae;Jung, Byeong Soo
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.365-372
    • /
    • 2014
  • In this paper, We implement a power-saving and efficient measures in buildings using the smart-meter. In order to save electric power energy, We propose an improved automatic power-factor controller(APFC) and demand control measures. This is achieved by controlling directly circuit breakers and the capacitor bank feeders in real time via a two-way smart-meter's ICT skills. Improved APFC is minimizing installation costs by series-parallel connecting heterologous capacitors to form a more diverse capacitor banking and controlling using the smart-meter. In order to suppress the demand power, We have designed a smart-meter with communication functions using Atmel's AVR465 and tested an operated lodging building for 24-hours. As a result, We made sure to always retained more than 95% power factor and did not occur over compensation.

A Study on Smart Peak Power Control System (스마트 최대 전력 관리 시스템 알고리듬 연구)

  • Lee, Woo cheol
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.227-228
    • /
    • 2013
  • The paper is related to smart maximum power system based on program logic. Especially, this system compares the total demand power with the target power by using the signal from the digital kilo watt meter. Based on the power information by the maximum power control equipment the consumed future power is anticipated. In addition, through consumed future power the controllable target power is set, and it applies on the maximum power control equipment. User or manager would control the load efficiently through the simple programming which could control load based on the control sequence and relay. So this system could control load more efficient and stable. Also the conventional load control circuit is not needed. Therefore, it is possible to improve the simple system configuration, which is resulted in cost effective and time saving. So this system is anticipated on time and coast.

  • PDF

A simulation on the energy saving based on different temperature tracing method and weather condition in electrical power plant (화력발전소 배관시스템의 운전 및 기후조건에 따른 에너지절감에 관한 시뮬레이션)

  • Han, Kyu-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.1
    • /
    • pp.67-74
    • /
    • 2014
  • Most of steam power plants in Korea are using the method of heating the feed water whenever the ambient temperature around the power plant area below $5^{\circ}C$ to prevent freezing water flowing in the pipe in winter time. But this kind of heat supplying system is not useful to save energy. If we take the method that the temperature of the each pipe is controled by direct measure of temperature by attaching sensor on the outside surface of the feed water tubes, then we can expect that a plenty of energy can be saved. In this study, the computer simulation is used to compare the energy consumption loads of both systems. Energy saving rate is calculated for the location of Incheon area in winter season. Four convection heat transfer coefficients for the ambient air and three initial flowing water temperature inside the tube were used. The result shows that the temperature control system using sensor represents more than 95% of energy saving rate in Incheon area. Even in the severe January weather condition, the energy saving rate is almost 75% in two days basis and even 83% in one day basis.

Study on the Causes of Malfunctions of PCBs Applied to the Power Saving Mode of Electrical Systems and its Solution (전기시스템의 절전모드에 적용되는 PCB의 오작동 원인 개선에 관한 연구)

  • Park, Hyung-Ki;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.51-55
    • /
    • 2013
  • The purpose of this study is to find the causes of malfunctions and defective operation of printed circuit boards(PCBs) built into home refrigerators to perform power saving functions. This study performed an electrostatic test of a PCB built-in using an Auto Triggering system; lightning and impulse tests using an LSS-15AX; and an impulse test using an INS-400AX. From the analysis of a secondarily developed product, it was found that electrostatic discharge(ESD) caused more malfunctions and defective operations than electric overstress(EOS) due to overvoltage. As a result of increasing the condenser capacity of the PCB circuit, withstanding voltage was increased to 7.4 kV. In addition, this study changed the power saving mode and connected a varistor to the #2 pin of an IC chip. As a result, the system consisting of all specimens of a finally developed product was operated stably with an applied voltage of less than 10 kV. This study found it necessary to perform quality control at the manufacturing stage in order to reduce the occurrence of electrostatic accidents to IC chips built into a PCB.

Intelligent Green House Control System based on Deep Learning for Saving Electric Power Consumption (전력 소모 절감을 위한 딥 러닝기반의 지능형 그린 하우스 제어 시스템)

  • Shin, Hyeonyeop;Yim, Hyokyun;Kim, Won-Tae
    • Journal of IKEEE
    • /
    • v.22 no.1
    • /
    • pp.53-60
    • /
    • 2018
  • Smart farm dissemination by continuously developing IoT is one of the best solution for decreasing labor in Korea farming area because of ageing. For this reason, the number of Smart farm in Korea is being increased. The Smart farm can control farming environment such as temperature for human. Specially, The important thing is controlling proper temperature for farming. In order to control the temperature, legacy smart farms are usually using pans or air conditioners which can control the temperature. However, those devices result in increasing production cost because the electric power consumption is high. For this reason, we propose a smart farm which can predict the proper temperature after an hour by using Deep learning to minimize the electric power consumption by controlling window instead of pans or air conditioners. We can see the 83% of electric power saving by means of the proposed smart farm.