• Title/Summary/Keyword: Power Performance Evaluation

Search Result 1,686, Processing Time 0.036 seconds

Study of the Method for Building up BSC in the Foodservice Industry Based on the Performance Evaluation (외식기업의 성과 평가에서의 BSC 도입 방법론 검토)

  • 오윤석
    • Culinary science and hospitality research
    • /
    • v.10 no.2
    • /
    • pp.84-106
    • /
    • 2004
  • Measuring and evaluating the business performance plays a very important role in managing business. It is both because business performance, in any types of industry, can be evaluated and managed properly only when the measurement of its performance is estimated and because its performance can be improved through an efficient and effective management. Therefore it is essential to build up the performance evaluation system to raise management efficiency of food service industry, to reinforce competitive power of food service industry. In this study, investigated the present performance evaluation system situation of the food service industry and introduced BSC as the main conceptional framework for evaluating the performance of the food service industry. Finally, this study discussed the possible method for building a balanced scorecard to the food service industry.

  • PDF

Green Mode Buck Switch for Low Power Consumption

  • Jang, KyungOun;Kim, Euisoo;Lim, Wonseok;Lee, MinWoo
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.397-398
    • /
    • 2013
  • Fairchild Green Mode off line buck switch for low standby power consumption and high reliability is presented. By reducing operating current and optimizing switching frequency, 20mW power consumption is achieved. High performance trans-conductance amplifier and green mode function improve the ripple and regulation in the output voltage. The conventional $FPS^{TM}$ buck and novel Fairchild buck switch are compared to show the improvement of performance. Experimental results are showed using 2W evaluation board.

  • PDF

Using Support Vector Machine Method to Improve Company Performance Management

  • Yuanhao LI;Xin LI;Han XIA
    • Asian Journal of Business Environment
    • /
    • v.13 no.4
    • /
    • pp.1-6
    • /
    • 2023
  • Purpose: To explore the application prospect of support vector machine (SVM) in supply chain management and its practical application in supply chain performance evaluation practice. Research design, data and methodology: This paper establishes the performance evaluation index system of supply chain management according to the balanced scorecard (BSC) theory, and establishes the SVM model of supply chain management performance evaluation based on the SVM principle. Results: The performance evaluation results of the supply chain of an electric power equipment Co., Ltd. in Harbin established by using the model are consistent with the actual situation, which indicates the nature and accuracy of the possible reflection of the established supply chain performance evaluation model. Conclusions: The results show that SVM model can be used to evaluate enterprise supply chain management performance indicators, and can improve enterprise supply chain management performance, thus demonstrating the effectiveness of the model.

Development of Human Performance Measures for Human Factors Validation in Advanced Nuclear Power Plants (신형원전 주제어실 인적요소 검증을 위한 인적수행도 평가척도 개발)

  • Ha, Jun-Su;Seong, Poong-Hyun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.85-96
    • /
    • 2006
  • Main control room(MCR) man-machine interface(MMI) design of advanced nuclear power plants(NPPs) such as APR(advanced power reactor)-1400 can be validated through performance-based tests to determine whether it acceptably supports safe operation of the plant. In this work, plant performance, personnel task, situation awareness, workload, teamwork, and anthropometric/physiological factor are considered as factors for the human performance evaluation. For development of measures in each of the factors, techniques generally used in various industries and empirically proven to be useful are adopted as main measures and some helpful techniques are developed in order to complement the main measures. Also the development of the measures is addressed based on the theoretical background. Finally we discuss the way in which the measures can be effectively integrated and then HUPESS(HUman Performance Evaluation Support System) which is in development based on the integrated way is briefly introduced.

Economic Evaluation of Coals Imported in Last 3 Years for Power Plant Based on Thermal Performance Analysis (최근 3년간 수입 유연탄 분석 및 연소열성능 해석을 활용한 석탄화력 발전소 탄종 경제성 평가 연구)

  • Baek, Sehyun;Park, Hoyoung;Ko, Sung Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.3
    • /
    • pp.44-53
    • /
    • 2013
  • In this study, the economic evaluation for imported coals was conducted for power plant based on thermo-dynamical performance analysis. The number of coal types considered was 1,755 imported by five power generation companies in Korea during the 2010-2012. The higher heating value (HHV) of the coals ranged 4,000-6,500 kcal/kg, mostly sub-bituminous. The 1D thermo-dynamical performance modeling was performed for a 500 MWe standard power plant using PROATES code. It was founded that the low rank coals had negative effects on the plant efficiency mainly due to the increased heat loss by moisture, hydrogen and flue gas. Based on the performance analysis, the economic performance of the coals was evaluated. The apparent price of low-rank coals tended to be significantly lower than design coal; for example, the unit price of coal with a HHV of 4,000 kcal/kg was 57% of the reference coal having 6,080 kcal/kg. Considering the negative effects leading to a decrease in the thermal performance, heating value compensation, and increased parasite load, the corrected unit cost for the coal with 4,000 kcal/kg was 90.7% of the reference coal. Overall, the cost saving by imported coals was not high as expected.

An Adaptive Power Saving Mechanism in IEEE 802.11 Wireless IP Networks

  • Pack Sangheon;Choi Yanghee
    • Journal of Communications and Networks
    • /
    • v.7 no.2
    • /
    • pp.126-134
    • /
    • 2005
  • Reducing energy consumption in mobile hosts (MHs) is one of the most critical issues in wireles/mobile networks. IP paging protocol at network layer and power saving mechanism (PSM) at link layer are two core technologies to reduce the energy consumption of MHs. First, we investigate the energy efficiency of the current IEEE 802.11 power saving mechanism (PSM) when IP paging protocol is deployed over IEEE 802.11 networks. The result reveal that the current IEEE 802.11 PSM with a fixed wakeup interval (i.e., the static PSM) exhibits a degraded performance when it is integrated with IP paging protocol. Therefore, we propose an adaptive power saving mechanism in IEEE 802.11-based wireless IP networks. Unlike the static PSM, the adaptive PSM adjusts the wake-up interval adaptively depending on the session activity at IP layer. Specifically, the MH estimates the idle periods for incoming sessions based on the exponentially weighted moving average (EWMA) scheme and sets its wake-up interval dynamically by considering the estimated idle period and paging delay bound. For performance evaluation, we have conducted comprehensive simulations and compared the total cost and energy consumption, which are incurred in IP paging protocol in conjunction with various power saving mechanisms: The static PSM, the adaptive PSM, and the optimum PSM. Simulation results show that the adaptive PSM provides a closer performance to the optimum PSM than the static PSM.

A comparison of the performance characteristics of large 2 MW and 3 MW wind turbines on existing onshore wind farms

  • Bilgili, Mehmet;Ekinci, Firat;Demirdelen, Tugce
    • Wind and Structures
    • /
    • v.32 no.2
    • /
    • pp.81-87
    • /
    • 2021
  • The aim of the current study is to compare the performance of large 2 MW and 3 MW wind turbines operating on existing onshore wind farms using Blade Element Momentum (BEM) theory and Angular Momentum (AM) theory and illustrate the performance characteristic curves of the turbines as a function of wind speed (U∞). To achieve this, the measurement data obtained from two different Wind Energy Power Plants (WEPPs) located in the Hatay region of Turkey was used. Two different horizontal-axis wind turbines with capacities of 2 MW and 3 MW were selected for evaluation and comparison. The hub-height wind speed (UD), turbine power output (P), atmospheric air temperature (Tatm) and turbine rotational speed (Ω) data were used in the evaluation of the turbine performance characteristics. Curves of turbine power output (P), axial flow induction factor (a), turbine rotational speed (Ω), turbine power coefficient (CP), blade tip speed ratio (λ), thrust force coefficient (CT) and thrust force (T) as a function of U∞ were obtained for the 2 MW and 3 MW wind turbines and these characteristic curves were compared. Results revealed that, for the same wind speed conditions, the higher-capacity wind turbine (3 MW) was operating at higher turbine power coefficient rates, while rotating at lower rotational speed ratios than the lower-capacity wind turbine (2 MW).

Standardized Design of the Transmitting Coils in Inductive Coupled Endoscope Robot Driving Systems

  • Ke, Quan;Jiang, Pingping;Yan, Guozheng
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.835-847
    • /
    • 2017
  • A transmitting coil with an optimal topology and number of turns can effectively improve the performance of the wireless power transfer (WPT) systems for endoscope robots. This study proposes the evaluation parameters of the transmitting coils related to the performance of the WPT system to standardize the design of the transmitting coils. It considers both the quality factor of transmitting coils and the coupling factor between the two sides. Furthermore, an analytical model of transmitting coils with different topologies is built to exactly estimate the evaluation parameters. Several coils with the specified topologies are wound to verify the analytical model and the feasibility of evaluation parameters. In the case of a constant power received, the related evaluation parameters are proportional to the transfer efficiency of the WPT system. Therefore, the applicable frequency ranges of transmitting coils with different topologies are determined theoretically. Then a transmitting coil with a diameter of 69 cm is re-optimized both theoretically and experimentally. The transfer efficiency of the WPT system is increased from 3.58% to 7.37% with the maximum magnetic field intensity permitted by human tissue. Finally, the standardized design of the transmitting coil is achieved by summing-up and facilitating the optimization of the coils in various situations.

Development of Performance Evaluation Program for Air-Operated Valve (공기구동 밸브 성능평가 프로그램 개발)

  • Yang, Sang-Min;Park, Jong-Kun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.5
    • /
    • pp.400-405
    • /
    • 2008
  • Air-operated valve is one of principal valves that are used to control fluid flow in nuclear power plants. It is necessary to evaluate periodically the performance of the AOV(Air-Operated Valve) which is used for controlling flow and pressure in nuclear power plants. In this study, we developed the integrated program HAES including hardware system to evaluate the performance of AOV. HAES(HANVIT AOV Evaluation System) consists of many modules such as valve information, thrust and torque analysis, actuator analysis, weak analysis and margin analysis. We applied with the test valve and showed that results evaluated by HAES is similar to those offered in the plant.

Insulation Design and Reliability Evaluation of ±80kV HVDC XLPE Cables

  • Jung, Chae-Kyun;Park, Hung-Sok;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.1002-1008
    • /
    • 2014
  • This paper describes insulation design and its reliability evaluation of ${\pm}80kV$ HVDC XLPE cable. Recently, the construction of HVDC transmission system, which is combined overhead line with underground cable, has been completed. This system is installed with existing 154 kV AC transmission line on the same tower. In this paper, the lightning transient analysis is firstly reviewed for selection of basic impulse insulation level and nominal insulation thickness. Then the electrical performance tests including load cycle test and superimposed impulse test based on CIGRE TB 496 are performed to evaluate the reliability of newly designed HVDC cable. There is no breakdown for ${\pm}80kV$ HVDC XLPE cable during electrical performance test. Finally, this system is installed in Jeju island based on successful electrical performance test (Type test). After installation tests are also successfully completed.