• Title/Summary/Keyword: Power Monitoring System

Search Result 1,937, Processing Time 0.028 seconds

Design and Implementation of the frequency Monitoring System for the Small AC Generator (소형 AC 발전기의 주파수 모니터링 시스템 설계 및 구현)

  • Park, Ji-sang;Jeon, Min-ho;Lee, Myung-eui
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.997-999
    • /
    • 2013
  • In this paper, the frequency monitoring system for the small AC generator having two or more generator is designed and implemented to synchronize a voltage, phase and frequency for stable power supply. CT sensor is used to measure the amount of current flowing in the power line, and PT sensor is used to measure the amount of voltage across the power line. The experimental results show that the power frequency can be measured using the power frequency monitoring system developed in this paper. The frequency monitoring system proposed in this paper will be able to control the power generation system using two or more small generator efficiently.

  • PDF

Fault Prediction of Photovoltaic Monitoring System based on Power Generation Prediction Model (발전량 예측 모델 기반의 태양광 모니터링 시스템 고장 예측)

  • Hong, Jeseong;Park, Jihoon;Kim, Youngchul
    • Journal of Platform Technology
    • /
    • v.6 no.2
    • /
    • pp.19-25
    • /
    • 2018
  • Existing Photovoltaic(PV) monitoring system monitors the current, past power generation, all values of environmental sensors. It is necessary to predict solar power generation for efficient operation and maintenance on the power plant. We propose a method for estimating the generation of PV data based PV monitoring system with data accumulation. Through this, we intend to find the failure prediction of the photovoltaic power plant in proportion to the predicted power generation. As a result, the administrator can predict the failure of the system it will be prepared in advance.

A wireless monitoring system for monocrystalline PV system

  • Kelebekler, Ersoy;Ergun, Riza Emre
    • Advances in Energy Research
    • /
    • v.7 no.2
    • /
    • pp.123-134
    • /
    • 2020
  • Photovoltaic systems are progressively attached importance and their installed capacity increases day by day because of their reliability, decremented installation and operating cost and simple construction structure. Generated power obtained from a photovoltaic system changes depending upon regional distinctness, and It can be estimated approximately by taking into consideration mean global radiation amount, temperature and humidity. However, there may be different regional negative or positive factors like dust, air pollution, desert powder which affect generated power. The best reliable data for a region can be obtained from the existing photovoltaic system in the region. For this purpose, a monitoring system for 1000W monocrystalline photovoltaic system constructed at Kocaeli University Uzunciftlik Nuh Cimento Vocational High Scholl is prepared. The installed monitoring system shows and records real values generated from the photovoltaic system and environmental data. In the study, Instantaneous data obtained from the monitoring system for October 2018 and 7th October 2018 is given within figures. Additionally, daily and monthly total energy productions of the photovoltaic system are given for October 2018 and date interval between July 2018 and March 2018, respectively.

Development of "K-WAMS" Wide Area Monitoring System based on Synchro-Phasor (시간 동기 데이터를 이용한 광역계통 감시시스템 "K-WAMS"구현)

  • Kim, Sang-Tae;Kim, Ji-Young;Lee, Dong-Chul;Song, Wan-Suk;Jang, Su-Hyung;Kim, Young-Don
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.44-46
    • /
    • 2008
  • K-WAMS based on i-PIU as a synchro-phasor data acquisition device using GPS can treat a monitoring and evaluation of wide area power system to detect a various symptoms of wide area disturbances and prevent large blackout. This paper introduced the development of K-WAMS such like WAMS(Wide Area Monitoring System).

  • PDF

The intelligent solar power monitoring system based on Smart Phone (스마트폰 기반의 지능형 태양광 전력적산 모니터링 시스템에 관한 연구)

  • Kim, Gwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.10
    • /
    • pp.1949-1954
    • /
    • 2016
  • Smart grid technology can be called grid techniques to improve the efficiency of the electric power by exchanging bidirectional information of electric power with real-time between electric power suppliers and consumers. Recently, the solar power generation system is being applied actively. However the solar power system has several problems leading to reduce overall electricity generation, because the difficult of the diagnosis and the solar power system failure such as PV(PhotoVoltaics) and inverter. In order to build an efficient smart grid, a stable electric power energy requirements capture and management and early fault detection is essentially required in solar power generation system. In this paper, it is designed to monitor the operating status of the solar power monitoring system from a remote location through a RS-485 or TCP/IP communication module to monitoring the output of solar power energy and abnormal phenomenon, to developing the measurement module and to transfer measured data.

Power disturbance measurement system using discrete wavelet transform (이산웨이블릿을 이용한 전력외란 측정 시스템)

  • 이진목;김홍균;최재호;이상훈
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.527-533
    • /
    • 2003
  • Recently, need of power stability and reliability has been increased as the spread of the sensitive electronic loads. Therefore, the power quality(PQ) problems become the hot Issue of public interest in these days. Many kinds of algorithms have been studied for the monitoring of PQ problems using the monitoring algorithms with RMS or FFT scheme, but it is still not enough to measure all of the PQ problems. This paper proposed the application of discrete wavelet transform(WT) for the PQ problems monitoring with the Introduction of WT theory, and the design of PQ monitoring data acquisition system Is described with some experimental results to verify the validity of the proposed PQ monitoring algorithm.

Development of Monitoring System for Interconnection of Distributed Generation with Power Grid (분산전원 계통 연계를 위한 모니터링 시스템의 개발)

  • Oh, Sung-Nam;Son, Young-Ik;Kim, Kab-Il
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.714-716
    • /
    • 2004
  • Owing to the environmental problems as well as increasing energy prices and power plant construction costs, many researches have been made for the safe operation of distributed generations. In order to be more popularly used in parallel with the distribution network, the distributed generation and its correlation with the power system should be exactly monitored at any time. This paper presents a monitoring system which displays the important states of the distributed generation in operation and stores various measurements of the system. The proposed system constructs a data-base for developing algorithms against any faults of the interconnected system, and monitors efficiently at any place with the communication network function.

  • PDF

Development of On-Line Partial Discharge Monitoring System in High Voltage Motors (고압전동기 운전중 부분방전 감시 시스템 개발)

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1175-1178
    • /
    • 2004
  • On-line partial discharge(PD) monitoring system has been developed to monitor in operating large motor stator insulations. This system makes use of remote diagnosis techniques for the evaluation of PD activity in the control center of thermal power plant. This system can be remotely accessed via a modem to build database, analyze status and interpret the pattern of PD activity. A personnel computer is generally connected to ten motors to continuous measurement of the PD activity. The test data can be easily interpreted by a maintenance staff. For assessing the condition of stator winding in motors, this system ensures a reliable measurement and accurate estimation. Capacitive couplers used for on-line PD measurement have been 80pF. The maximum PD magnitude(Qmax), PD pattern and normalized quantity number(NQN) were performed by this system.

  • PDF

A Study on the Power Loss Monitoring Methods with AMI systems (지능형 원격검침시스템을 이용한 전력손실 감시방법에 대한 연구)

  • Myoung, No-Gil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.67-74
    • /
    • 2013
  • Major utilities have been focusing on R&D and nationwide business of AMI system which plays a vital role in SmartGrid whose concept is to maximize energy efficiency and optimize electric power facility management with exchanging real time information between utilities and consumers based on ICT technologies in power grid. In this paper, we suggest a power loss monitoring method using KEPCO's AMI system which is operating in fields and with the acquisition of AMI data and analyses verify the validation of a power loss monitoring method.

Simulation and Analysis of the Network Traffic of a Power Infrastructure Defense System (광역 방어시스템의 통신 트래픽 모사와 분석)

  • Baek, Yoon-Ki;Yi, Keon-Young
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.179-180
    • /
    • 2006
  • The real time monitoring of the power systems covering wide area are essential for the stable operation and control of the power system. Synchronized phasor measurement is a key for the precise monitoring and control of the power systems. In this paper, to suggest an appropriate network topology of Power Infrastructure Defense System(PIDS) and to estimate the maximum network bandwidth with using the network analyzer, we simulate a PIDS and analyze the network traffic.

  • PDF