• 제목/요약/키워드: Power Measurement

검색결과 4,625건 처리시간 0.041초

광역 방어시스템의 통신 트래픽 모사와 분석 (Simulation and Analysis of the Network Traffic of a Power Infrastructure Defense System)

  • 백윤기;이건영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.179-180
    • /
    • 2006
  • The real time monitoring of the power systems covering wide area are essential for the stable operation and control of the power system. Synchronized phasor measurement is a key for the precise monitoring and control of the power systems. In this paper, to suggest an appropriate network topology of Power Infrastructure Defense System(PIDS) and to estimate the maximum network bandwidth with using the network analyzer, we simulate a PIDS and analyze the network traffic.

  • PDF

3상 전력을 기반으로 한 시스템 해석 컴퓨터 (Computer Based Three Phase Power Analysing System)

  • 위제;박영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.675-676
    • /
    • 2008
  • The computer based three phase power analysing system has been developed as a traveling standard for onsite power calibration. The system is utilized with digital-to-analog converts which were synchronized each other. Using digital signal processing technique the software has been developed to calculate power parameters. The calibration system is fully traceable to national standard system and, accuracy allows the calibration of industrial power measurement systems.

  • PDF

풍력발전 시스템의 계통연계에 따른 전력품질 모니터링 및 진단 (Power Quality Monitoring and Diagnosis for the Distribution System Interconn of Wind Turbine)

  • 장석명;이성호;윤인기;조한욱;윤기갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.251-253
    • /
    • 2002
  • Various measures of power quality are addressed, specifically power factor, power variability, electrical transients, flicker and harmonics. This paper presents the measurement criteria for monitoring and diagnosis of power quality according to the distribution system interconnection of wind turbine.

  • PDF

MICS 표준에 기반한 무선 텔레메트리 시스템 개발 (Development of a wireless telemetry system based on MICS standard)

  • 이승하;박일용
    • 센서학회지
    • /
    • 제18권1호
    • /
    • pp.63-71
    • /
    • 2009
  • It is said that the desirable bio-signal measurement and stimulation system should be an implantable type if the several problems such as biocompatibility, electrical safety, and so on are overcome. In addition to the biocompatibility issue, a robust RF communication and a stable electrical power source for the implantable bio-signal measurement and stimulation system are very important matters. In this paper, a wireless telemetry system which adopts the FCC's approved MICS (medical implant communication service) protocol and a wireless power transmission has been proposed. The proposed system composed of a base station (BS) and an implantable medical device (IMD) has the advantages that the interference with other RF devices can be reduced by the use of the specially assigned MICS frequency band of 402.MHz to 405 MHz. Also, the proposed system includes various functions of a multi-channel bio-signal acquisition and an electric stimulation. Since the electrical power for the IMD can be provided by the inductive link between PCB patterned coils, the IMD needs no battery so that the IMD can be smaller size and much less dangerous than the active type IMD which includes the internal battery. Finally, the validity as a wireless telemetry system has been demonstrated through the experiments by using the implemented BS and IMD.

전력 유도 장애 발생 시 통신 선로의 접지체 임피던스 크기가 유도 잡음 전압에 미치는 영향 분석 (Analysis on the Effects of the Induced Noise Voltage with the Impedance Changes of Telecommunication Line in the Power Inducting Situation)

  • 최문환;이상무;조평동
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.227-230
    • /
    • 2007
  • In this paper, we have analyzed the change characteristics of induced noise due to the impedance change of the ground in both ends of telecommunication line. As what affects the induced noise, there are power influence or longitudinal transverse voltages and its weighted filtered voltage. In the result of measurement, we can see the noise level change due to the change of the ground impedance, that is, as the ground impedance at either end of the telecommunication line become grower, the noise level is increased, and as the ground impedance at either end of the telecommunication line become smaller, the noise level is decreased. However, we can't define the relation between ground impedance size and PIF in these measurement results, so we will have to carry out the measurement more deeply and more practically with various conditions in environmental viewpoint and/or experimental viewpoint to establish the definition between ground impedance size and PIF.

  • PDF

전력케이블내 반도전 재료의 전기적 및 기계적 특성; 체적저항과 Stress-Strain 측정 (Electrical and Mechanical Properties of Semiconductive Shield in Power Cable; Volume Resistivity and Stress-Strain Measurement)

  • 이경용;양종석;최용성;박대희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권2호
    • /
    • pp.45-50
    • /
    • 2005
  • To improve mean-life and reliability of power cable, in this study, we have investigated electrical properties and stress-strain showing by changing the content of carbon black that is semiconductive additives for underground power transmission. Specimens were made of sheet form with the nine of specimens for measurement. Volume resistivity of specimens was measured by volume resistivity meter after 10 minutes in the pre-heated oven of both 25±1 [℃] and 90±1 [℃]. And stress-strain of specimens was measured by TENSOMETER 2000. A speed of measurement was 200[mm/min], ranges of stress and strain were 400[Kgf/㎠] and 600[%]. In addition tests of stress-strain were progressed by aging specimens in air oven. From this experimental results, volume resistivity was high according to increasing the content of carbon black. And yield stress was increased, while strain was decreased according to increasing the content of carbon black. And stress-strain were decreased some after aging because of oxidation reaction of chemical defect. We could know EEA was excellent more than other specimens from above experimental results.

Pulse-Mode Dynamic Ron Measurement of Large-Scale High-Power AlGaN/GaN HFET

  • Kim, Minki;Park, Youngrak;Park, Junbo;Jung, Dong Yun;Jun, Chi-Hoon;Ko, Sang Choon
    • ETRI Journal
    • /
    • 제39권2호
    • /
    • pp.292-299
    • /
    • 2017
  • We propose pulse-mode dynamic $R_on$ measurement as a method for analyzing the effect of stress on large-scale high-power AlGaN/GaN HFETs. The measurements were carried out under the soft-switching condition (zero-voltage switching) and aimed to minimize the self-heating problem that exists with the conventional hard-switching measurement. The dynamic $R_on$ of the fabricated AlGaN/GaN MIS-HFETs was measured under different stabilization time conditions. To do so, the drain-gate bias is set to zero after applying the off-state stress. As the stabilization time increased from $ 0.1{\mu}s$ to 100 ms, the dynamic $R_on$ decreased from $160\Omega$ to $2\Omega$. This method will be useful in developing high-performance GaN power FETs suitable for use in high-efficiency converter/inverter topology design.

Power spectra of wind forces on a high-rise building with section varying along height

  • Huang, D.M.;Zhu, L.D.;Chen, W.
    • Wind and Structures
    • /
    • 제18권3호
    • /
    • pp.295-320
    • /
    • 2014
  • The characteristics of amplitudes and power spectra of X axial, Y axial, and RZ axial (i.e., body axis) wind forces on a 492 m high-rise building with a section varying along height in typical wind directions are studied via a rigid model wind tunnel test of pressure measurement. Then the corresponding mathematical expressions of power spectra of X axial (across-wind), Y axial (along-wind) and torsional wind forces in $315^{\circ}$ wind directions are proposed. The investigation shows that the mathematical expressions of wind force spectra of the main structure in across-wind and torsional directions can be constructed by the superimposition of an modified wind spectrum function and a peak function caused by turbulent flow and vortex shedding, respectively. While that in along-wind direction can only be constructed by the former and is similar to wind spectrum. Moreover, the fitted parameters of the wind load spectra of each measurement level of altitude are summarized, and the unified parametric results are obtained. The comparisons of the first three order generalized force spectra show that the proposed mathematical expressions accord with the experimental results well.

전력감시제어설비의 프로토콜 변경에 따른 데이터처리 품질측정 (Quality Measurement of Data Processing by a Protocol Change of Power SCADA System)

  • 이용두;최성만;유철중;장옥배
    • 정보처리학회논문지D
    • /
    • 제12D권7호
    • /
    • pp.1031-1038
    • /
    • 2005
  • 본 논문에서는 시스템 사용현황을 파악할 수 있는 데이터를 최대수용 트래픽양과 실제 트래픽량으로 구분해서 측정하며 프로토콜 변경에 따른 트래픽량 변화와 사고발생시의 과부하 조건에서의 트래픽을 분석할 것이다. 이로 인해 전력감시제어설비의 안전성을 극대화할 수 있는 계기를 미련하고자 한다 또한, 현재 유통되고 있는 트래픽이 어느 정도인지를 알고 그 증가율 추세를 파악하여 앞으로 예상되는 트래픽량을 미리 예측하여 필요한 대역폭을 미리 확보하는 자료로 활용하고, 네트워크 정보분석을 통한 한정된 네트워크 자원의 효율적인 배치로 안정된 전력감시페어시스템의 운용을 가능하게 함으로써 신뢰성을 향상시킬 수 있다.

Strain and deformation angle for a steel pipe elbow using image measurement system under in-plane cyclic loading

  • Kim, Sung-Wan;Choi, Hyoung-Suk;Jeon, Bub-Gyu;Hahm, Dae-Gi;Kim, Min-Kyu
    • Nuclear Engineering and Technology
    • /
    • 제50권1호
    • /
    • pp.190-202
    • /
    • 2018
  • Maintaining the integrity of the major equipment in nuclear power plants is critical to the safety of the structures. In particular, the soundness of the piping is a critical matter that is directly linked to the safety of nuclear power plants. Currently, the limit state of the piping design standard is plastic collapse, and the actual pipe failure is leakage due to a penetration crack. Actual pipe failure, however, cannot be applied to the analysis of seismic fragility because it is difficult to quantify. This paper proposes methods of measuring the failure strain and deformation angle, which are necessary for evaluating the quantitative failure criteria of the steel pipe elbow using an image measurement system. Furthermore, the failure strain and deformation angle, which cannot be measured using the conventional sensors, were efficiently measured using the proposed methods.