• 제목/요약/키워드: Power Measurement

검색결과 4,625건 처리시간 0.035초

DFIG의 전류 측정오차로 인한 발전전력의 리플 저감에 관한 연구 (Reduction of Power Ripples in a Doubly Fed Induction Generator Under Current Measurement Errors)

  • 김영일;김장목;황선환;김찬기;최영도
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.103-107
    • /
    • 2007
  • In doubly fed induction generators (DFIGs), control of rotor currents allows for adjustable speed operation, active, and reactive power control. This paper presents a DFIG control strategy that enhances the active and reactive power control with controllers that can compensate for the errors caused by current measurement path in the DFIG system. The errors can be divided into two categories: offset and scaling errors. These can induce the speed, active, and reactive power pulsations, which are one and two times the fundamental slip frequency in the DFIG. And these undesirable ripples can do the DFIG harm. In this paper, a new compensation algorithm is proposed. Therefore, the proposed algorithm has several advantages: to implement is easy; it require less computation time; it is robust with regard to the variation of the induction generator parameters. In this paper, a new algorithm is introduced by using the integral of phase currents to measure the current ripples of rotor-side converterin the DFIG system. The experiment results are shown the effectiveness of the proposed method.

  • PDF

(-) 구면 렌즈 면의 반사상에 의한 굴절력 측정 (Measurement of Refractive Power by Reflective image on the Negative Spherical Lens)

  • 최운상;김대현
    • 한국안광학회지
    • /
    • 제9권2호
    • /
    • pp.417-421
    • /
    • 2004
  • 안경렌즈 면 위에 반사되는 상을 관찰하연 한 물체에 대해 두 개의 상이 나타나 있다. 이것은 렌즈 전면에서 반사되는 상과 렌즈 후면에서 반사되는 상이다. 이 상들은 렌즈 전, 후면의 굴절력에 의해 렌즈 면에서 반사되는 상이며, 렌즈 전체의 굴절력은 렌즈 전, 후면의 굴절력을 이용하면 얻을 수가 있다. 그러므로 렌즈 면 위에서 나타나는 상 크기 측정은 렌즈의 굴절력을 측정하는 기기의 도움 없이 렌즈의 굴절력을 측정하는 방법이 될 수 있다. 렌즈 면 위에서 측정된 두 개 반사상의 비와 굴절력을 측정하여 계산한 값과 비교하였다.

  • PDF

Experimental Investigations for Thermal Mutual Evaluation in Multi-Chip Modules

  • Ayadi, Moez;Bouguezzi, Sihem;Ghariani, Moez;Neji, Rafik
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1345-1356
    • /
    • 2014
  • The thermal behavior of power modules is an important criterion for the design of cooling systems and optimum thermal structure of these modules. An important consideration for high power and high frequency design is the spacing between semiconductor devices, substrate structure and influence of the boundary condition in the case. This study focuses on the thermal behavior of hybrid power modules to establish a simplified method that allows temperature estimation in different module components without decapsulation. This study resulted in a correction of the junction temperature values estimated from the transient thermal impedance of each component operating alone. The corrections depend on mutual thermal coupling between different chips of the hybrid structure. A new experimental technique for thermal mutual evaluation is presented. Notably, the classic analysis of thermal phenomena in these structures, which was independent of dissipated power magnitude and boundary conditions in the case, is incorrect.

측정방법별 가전제품의 음향파워레벨 (Sound Power Level of Electric Home Appliances according to Measurement Method)

  • 강대준;구진회;이재원
    • 한국소음진동공학회논문집
    • /
    • 제19권4호
    • /
    • pp.335-346
    • /
    • 2009
  • As the economy has grown and the main industry in Korea has been changed from secondary industry to tertiary industry, the importance of indoor environment has been a matter of common concern, in which one of the main concerns is to improve the indoor acoustic conditions. However, even though this is required more than before, there are no measures to protect the human being from the noise of electric home appliances. This is owing to the absence of the data about sound power level of electric home appliances. So, we investigate the sound power level of them and analyze the acoustical characteristics of each one. First, we tried to investigate the sound power measurement method of each electric home appliance. After it we test the sound power level of them. From the survey, we can know that the vacuum cleaner is the most noisy electric home appliance, and the refrigerator is the least noisy one. This results will help us predict the indoor noise level using the basic data of sound power level.

전력구 내 전자기파에 대한 작업 환경 측정 (The Measurement of Electromagnetic Wave in Power Cable Tunnel of Underground Utility Tunnel)

  • 강대곤;박재학
    • 한국안전학회지
    • /
    • 제34권1호
    • /
    • pp.1-7
    • /
    • 2019
  • Electromagnetic measurements of the power cable tunnel were conducted from August 10 to 20, 2018, in the ${\bigcirc}{\bigcirc}$ city underground utility tunnel. During this period, the average temperature was $31.89^{\circ}C$ and the humidity was 67.56% in power cable tunnel. As a result of the electromagnetic measurement, the highest electric field was 25.3 V/m and the magnetic flux density was $42.6{\mu}T$. The average electric field was 18.56 V/m and the magnetic flux density was $29.32{\mu}T$ in the power cable tunnel. As a result of comparison with the electric equipment technical standard, the electric field in the power cable tunnel was 0.5% of the electric equipment standard and 35.2% of the magnetic flux density. It's similar value that electric field is about robotic vacuum(15.53 V/m), and magnetic flux density is similar value about capsule- type coffee machine ($23.07{\mu}T$). The number of cable lines and the size of the electromagnetic waves were not proportional to each other through comparison of cable lines in the power cable tunnel. It was confirmed that 154 kV, rather than 22.9 kV, could have a greater influence on occupational.

최대 리아프노프 지수를 활용한 전력계통 측정 데이터 기반 비선형 동요 현상 검출 방안 (MLE Based Power System Oscillation Detector by Using Measurement Data)

  • 조환희;이병준;남수철;김용학
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제4권2호
    • /
    • pp.55-61
    • /
    • 2018
  • 본 연구는 시각 동기 위상 측정 정보를 이용하여 전력계통에 나타나는 여러 가지 동요 현상을 검출하기 위한 기초 연구로써, 시계열 데이터 분석 분야로 분류된다. 제시한 방법은 비선형 동특성에 해석 기반으로 접근하여 전력계통에 나타날 수 있는 여러 동요 현상을 범용적으로 검출해 낼 수 있다. 비선형 동요 현상의 신호적 패턴을 수학적으로 기본 순시치 파형으로부터 피크치 샘플링을 통해 전개하여 계통 요소간 간섭으로 인한 원하지 않는 진동 모드를 검출하고자 한다. 계통의 변화로 진동 모드가 나타날 때, 2차원 평면에 실효치로 환산한 시계열 전압 데이터와 선형화된 플로퀘트 상수(Floquet multiplier)를 맵핑하여 도시하고, 정상상태 지점으로부터 거리를 계산하여 최대 리아프노프 지수 계산을 통해 계통이 불안정하게 되는 시간을 시계열 데이터 분석으로 추정하는 것이 본 방법의 핵심이다. 이러한 접근으로 제시한 비선형 동요 검출 알고리즘을 적용하여 디지털 필터 적용 또는 주파수 영역 해석과 같은 오프라인 Study와 달리 온라인으로 신속하게 계통의 현재 상태를 알 수 있게 된다.

전류측정성분과 불량정보 검출을 고려한 전력계통에서의 상태추정에 관한 연구 (State Estimation Considering Current Measurement Component and Bad Data Detection)

  • 김준현;이종범
    • 대한전기학회논문지
    • /
    • 제35권7호
    • /
    • pp.261-271
    • /
    • 1986
  • This paper describes a method for the state estimation considering current measurement component and detection of the bad data. The state values are estimated by weighted least square method in which measurement vector included bus injection current and line current. The bad data are detected using standardized variable of normal distribution and identified using sensitivity coefficients. When the bad data were occured by the bad measurement values. The results of the application to the model power system reveal the effectiveness of the presented algorithms.

  • PDF

Parameter Measurement of Induction Motors

  • Kim Kyung-Seo;Byun Sung-Hoon;Na Seung-Ho;Cho Byung-Guk;Kwon Bong-Hyun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.751-755
    • /
    • 2001
  • This paper presents the parameter measurement methods for high performance drive of induction motors. The proposed methods are selected by considering the factors that affect accuracy of measurement. Each method are refined to be adequate for measurement of each motor parameters. Proposed methods are easy to implement and only require inverter-motor system, which are important for practical application.

  • PDF

공압밸브의 동적응답 특성측정 자동화 시스템 개발 (Development of automatic measurement system for dynamic respose time of pneumatic solenoid valve)

  • 강보식;김형의
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.974-978
    • /
    • 1991
  • Electro-pneumatic valve is an electro-mechanical device which converts electric signal into pneumatic flow mu or pressure. A measurement of dynamic response time is very important to evaluate valve performance. Dynamic response time of electro-pneumatic valve has a variation accordance with valve types, operating way and test standard. In this study, automatic measurement system of dynamic response time is composed based on test condition of dynamic response time test standard(CETOP, JIS). Also, in this study test pressure variation characteristics accordance with variation of solenoid excitation power, and we developed dynamic response measurement system enable to compare of and analyze these two characteristics.

  • PDF

송풍기의 소음레벨 측정방법 (KS B6361, 2000년 개정내용을 중심으로) (Methods of A-weighted Sound Pressure Level Measurement for Fans and Blowers (KS B 6361, Focus on Revised Content made in 2000))

  • 김경호;이승배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.424-432
    • /
    • 2000
  • The revision was provided for the method of A-weighted sound pressure measurement for fans and blowers, in which the newly developed measurement techniques were applied to KS B 6361. This revision includes the sound power methods for radiated sound from the body, the in-duct measurement method, and the correction method for flow noise upon measuring microphone, etc.

  • PDF