• Title/Summary/Keyword: Power Measurement

Search Result 4,631, Processing Time 0.038 seconds

Analysis on Electrical Characteristics of Tabbing Cells According to Measurement Methods (측정방식에 따른 Tabbing Cell에서의 전기적 특성 분석)

  • Choi, Eun-Ji;Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1304-1305
    • /
    • 2011
  • In this study, tabbing cell samples in the soft touch method are compared samples according to soldering voltage conditions. Series resistance and power loss is measured by two measurement method. As a result, probe measurement method was found optimized soldering voltage optimized according to voltage condition and clamp measurement method was not difference. The purpose of this paper is to analysis the principle of measurement method.

  • PDF

A Study on the Development of the measurement system of the Power steering unit for Automobile (자동차용 Poewer steering unit 의 자동측정시스템 개발에 관한 연구)

  • 기창두;김상묵
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.925-928
    • /
    • 1995
  • Recently, the system of the industry demands quick and accurate measurement for the mass production and high quality. Also, we need to improve the accuracy to decrease the failure rate in automatic assembly processing and improve the confidence, durability and the compatibility of parts. To answer this tendency and requirement, we have developed many accrate measuring instruments and methods. In this paper, we develop the whidows program using the DSP board(TMS320C25) which is used the data acquisition and the Visual C $^{++}$ , a windows programming language. We perform the measurement, analysis and output process in GUI(Graphic User Interface)environment. By using system, we will save the time required for the hand-worked measurement and avoid the useless iterative measurement. Furthermore, we expect to improve the productivity through automotive quality control in manufacturing process.s.

  • PDF

A Methodology of Radiation Measurement of MOSFET Dosimeter (MOSFET 검출기의 방사선 측정 기법)

  • Lho, Young-Hwan;Lee, Sang-Yong;Kang, Phil-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.159-162
    • /
    • 2009
  • The necessity of radiation dosimeter with precise measurement of radiation dose is increased and required in the field of spacecraft, radiotheraphy hospital, atomic plant facility, etc. where radiation exists. Until now, a low power commercial metal-oxide semiconductor(MOS) transistor has been tested as a gamma radiation dosimeter. The measurement error between the actual value and the measurement one can occur since the MOSFET(MOS field-effect transistor) dosimeter, which is now being used, has two gates with same width. The measurement value of dosimeter depends on the variation of threshold voltage, which can be affected by the environment such as temperature. In this paper, a radiation dosimeter having a pair of MOSFET is designed in the same silicon substrate, in which each of the MOSFETs is operable in a bias mode and a test mode. It can measure the radiation dose by the difference between the threshold voltages regardless of the variation of temperature.

  • PDF

Measurement Data Comparison of Fast SAR Measurement System by Probe Arrays with Robot Scanning SAR Measurement System

  • Kim, Jun Hee;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.336-341
    • /
    • 2014
  • Dosimetry of radiating electromagnetic wave from mobile devices to human body has been evaluated by measuring Specific Absorption Rate (SAR). Usual SAR measurement system scans the volume by robot arm to evaluate RF power absorption to human body from wireless devices. It is possible to fast estimate the volume SAR by software deleting robot moving time with the 2D surface SAR data acquired by arrayed probes. This paper shows the principle of fast SAR measurement and the measured data comparison between the fast SAR system and the robot scanning system. Data of the fast SAR is well corresponding with data of robot scanning SAR within ${\pm}3$ dB, and its dynamic range covers from 10 mW/kg to 30 W/kg with 4.8 mm probe diameter.

A Study on the Measurement Technique of the Grounding Mesh Resistance by Field Measurements (현장실측에 의한 메시(Mesh)접지저항 출정기법 연구)

  • 한기붕;김삼수;정세중;이상익
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.426-429
    • /
    • 1999
  • In this paper, we have provided the measurement technique of the grounding mesh resistance by field measurements. The standard of measurement is specified in the IEEE Std 81.2-1991 and JEAC 5001-1988, which is the the fall-of-potential method by test-current injection, but this method is difficult to apply at field, where is small around a electric power substation of domestic. For the convenient measurement method, space of assistant probe and quantity of test-current injection are changed step for step. As the result, ' the proposed measurement technique of grounding mesh resistance is that the space of current and potential probes must be fixed at 150rn from a grounding mesh, the test-current injection has to keep 5A or more.

  • PDF

Three Dimensional Measurements and Parameter Identification of Force and Torque Distmbances of High Speed Rotating Actuators (고속회전구동기의 힘 및 토크 외란 3차원 측정과 파라미터 추정)

  • Lee, Hyun-Ho;Oh, Hwa-Suk;Cheon, Dong-Ik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.4
    • /
    • pp.409-416
    • /
    • 2007
  • A momentum type actuator produces force and torque disturbances as well as its designed control torque. These disturbances are ones of the largest disturbance sources inside the spacecraft, which deteriorate the pointing stability of the high precision spacecraft. The measurement and analysis of actuator disturbances are therefore imperative for such a spacecraft, and thus a three dimensional torque measurement table has been developed for that purpose. The data acquired from the measurement table are processed in the frequency domain and displayed in the power spectral density(PSD). Through this process, disturbance model parameters are obtained and used for the attitude stability simulation. The process has been adopted for the disturbance measurement of the reaction wheel, and the validity of measurements and parameter identification procedure is verified.

A Study on Successive Approximation Measurement of Mechanical Parameters for Motor Control System (전동기 제어시스템 기계정수의 점근적 추정에 관한 연구)

  • Ahn Jong-Keon;Park Seung-Kyu;Ahn Ho-Gyun
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.138-141
    • /
    • 2001
  • This paper presents a study on successive approximation measurement of mechanical parameters for motor control system. At the first step of servo system installation, control system gain tuning is troublesome work. Recently, autotuning method of motion controller for motor drive system is based on parameter measurement and identification. On the case of first order mechanical system (mechanical parameters are modified by simple inertia and friction), it is necessary for good response to get the accurate measurement or identification of the mechanical parameters . In this paper, novel method applies the binary successive approximation measurement to the inertia and friction coefficient. Computer simulation and experiment for the proposed method will show verification of accuracy and usefulness.

  • PDF

Application of Particle Swarm Optimization for Harmonic State Estimation (전력시스템 고조파 상태 추정에서 PSO 적용)

  • Wang, Y.P.;Jeong, J.W.;Kim, H.H.;An, B.C.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.529-530
    • /
    • 2007
  • The design of a measurement system to perform Harmonic State Estimation(HSE) is a very complex problem. In particular, the number of available harmonic analysis measurement instruments is always limited. Therefore, a systematic procedure is needed to design the optimal placement of measurement points. This paper presents an optimal algorithm of HSE which is based on an optimal placement of measurement points using PSO. This PSO-HSE has been applied to power system for the validation of an optimal algorithm of HSE. The study results have indicated an economical and effective method for optimal placement of measurement points using PSO in the HSE.

  • PDF

Recuction of the Influence of Background Noise in Sound Insulation Measurement (차음성능 측정에 있어서의 암소음의 영향의 저감 (2))

  • Yum, Sung-Gon;Tachibana, Hideki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.441-444
    • /
    • 2004
  • In the sound insulation measurements, the influence of background (extraneous) noise is often serious problem and how to reduce its effect and to improve the signal-to-noise(S/N) ratio is an important theme. As the background noise, such extraneous noises as road traffic noise and machine noise often disturb the measurement. In laboratory measurements on specimens with high sound insulation performances, even the internal noise of the measurement system can become a problem. To improve the signal-to-noise ratio and to improve the measurement accuracy, various kinds of digital signal processing techniques can be applied. In this paper, four kinds of digital signal processing techniques are applied and their effectiveness is examined through field measurements.

  • PDF

A Study on the Measurement Method of Test Waveform for System-level HEMP Immunity Test (체계 수준 HEMP 내성 시험을 위한 시험파형 계측 기법 연구)

  • Yeo, Saedong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.233-240
    • /
    • 2019
  • High-altitude ElectroMagnetic Pulse(HEMP) is a high-power electromagnetic pulse caused by nuclear explosions at altitudes above 30 km. This pulse can cause serious damage to the electrical/electronic device. Therefore, there are a lot of studies on the effects of HEMP in the literature. When conducting studies on the effects of HEMP, it is essential to measure the simulated HEMP. Depending on the need for measurement, this paper focuses on the HEMP measurement method. This paper proposes a measurement method using frequency domain compensation to extract the correct waveform and solves the offset problem more efficiently than the conventional methods. The proposed method is verified by experiment using HEMP simulator and measurement system in ADD.