• Title/Summary/Keyword: Power Measurement

Search Result 4,641, Processing Time 0.032 seconds

A DSP based Three Phase Power Quality Analyzer for Motor Drives (모터 구동장치를 위한 DSP기반 3상 전력품질분석 시스템)

  • 정영국
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.661-664
    • /
    • 2000
  • This paper presents a digital instrument for the power quality analysis in three phase power system where current waveform is non-sinusoidal. It is based on C31 DSP and on a special high-speed data acquisition system. Voltage and current waveforms are acquired and processed by using a simple average power algorithm, The paper also goes on to discuss the performance of an instrument prototype both in terms of accuracy and speed of measurement.

  • PDF

Simulation and Analysis of the Network Traffic of a Power Infrastructure Defense System (광역 방어시스템의 통신 트래픽 모사와 분석)

  • Baek, Yoon-Ki;Yi, Keon-Young
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.179-180
    • /
    • 2006
  • The real time monitoring of the power systems covering wide area are essential for the stable operation and control of the power system. Synchronized phasor measurement is a key for the precise monitoring and control of the power systems. In this paper, to suggest an appropriate network topology of Power Infrastructure Defense System(PIDS) and to estimate the maximum network bandwidth with using the network analyzer, we simulate a PIDS and analyze the network traffic.

  • PDF

Computer Based Three Phase Power Analysing System (3상 전력을 기반으로 한 시스템 해석 컴퓨터)

  • Wijesinghe, W.M.S.;Park, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.675-676
    • /
    • 2008
  • The computer based three phase power analysing system has been developed as a traveling standard for onsite power calibration. The system is utilized with digital-to-analog converts which were synchronized each other. Using digital signal processing technique the software has been developed to calculate power parameters. The calibration system is fully traceable to national standard system and, accuracy allows the calibration of industrial power measurement systems.

  • PDF

Power Quality Monitoring and Diagnosis for the Distribution System Interconn of Wind Turbine (풍력발전 시스템의 계통연계에 따른 전력품질 모니터링 및 진단)

  • Jang, S.M.;Lee, S.H.;Yoon, I.K.;Cho, H.W.;Yoon, K.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.251-253
    • /
    • 2002
  • Various measures of power quality are addressed, specifically power factor, power variability, electrical transients, flicker and harmonics. This paper presents the measurement criteria for monitoring and diagnosis of power quality according to the distribution system interconnection of wind turbine.

  • PDF

Development of a wireless telemetry system based on MICS standard (MICS 표준에 기반한 무선 텔레메트리 시스템 개발)

  • Lee, Seung-Ha;Park, Il-Yong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.63-71
    • /
    • 2009
  • It is said that the desirable bio-signal measurement and stimulation system should be an implantable type if the several problems such as biocompatibility, electrical safety, and so on are overcome. In addition to the biocompatibility issue, a robust RF communication and a stable electrical power source for the implantable bio-signal measurement and stimulation system are very important matters. In this paper, a wireless telemetry system which adopts the FCC's approved MICS (medical implant communication service) protocol and a wireless power transmission has been proposed. The proposed system composed of a base station (BS) and an implantable medical device (IMD) has the advantages that the interference with other RF devices can be reduced by the use of the specially assigned MICS frequency band of 402.MHz to 405 MHz. Also, the proposed system includes various functions of a multi-channel bio-signal acquisition and an electric stimulation. Since the electrical power for the IMD can be provided by the inductive link between PCB patterned coils, the IMD needs no battery so that the IMD can be smaller size and much less dangerous than the active type IMD which includes the internal battery. Finally, the validity as a wireless telemetry system has been demonstrated through the experiments by using the implemented BS and IMD.

Analysis on the Effects of the Induced Noise Voltage with the Impedance Changes of Telecommunication Line in the Power Inducting Situation (전력 유도 장애 발생 시 통신 선로의 접지체 임피던스 크기가 유도 잡음 전압에 미치는 영향 분석)

  • Choi, Mun-Hwan;Lee, Sang-Mu;Cho, Pyoung-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.227-230
    • /
    • 2007
  • In this paper, we have analyzed the change characteristics of induced noise due to the impedance change of the ground in both ends of telecommunication line. As what affects the induced noise, there are power influence or longitudinal transverse voltages and its weighted filtered voltage. In the result of measurement, we can see the noise level change due to the change of the ground impedance, that is, as the ground impedance at either end of the telecommunication line become grower, the noise level is increased, and as the ground impedance at either end of the telecommunication line become smaller, the noise level is decreased. However, we can't define the relation between ground impedance size and PIF in these measurement results, so we will have to carry out the measurement more deeply and more practically with various conditions in environmental viewpoint and/or experimental viewpoint to establish the definition between ground impedance size and PIF.

  • PDF

Electrical and Mechanical Properties of Semiconductive Shield in Power Cable; Volume Resistivity and Stress-Strain Measurement (전력케이블내 반도전 재료의 전기적 및 기계적 특성; 체적저항과 Stress-Strain 측정)

  • Lee Kyoung-Yong;Yang Jong-Seok;Choi Yong-Sung;Park Dae-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.2
    • /
    • pp.45-50
    • /
    • 2005
  • To improve mean-life and reliability of power cable, in this study, we have investigated electrical properties and stress-strain showing by changing the content of carbon black that is semiconductive additives for underground power transmission. Specimens were made of sheet form with the nine of specimens for measurement. Volume resistivity of specimens was measured by volume resistivity meter after 10 minutes in the pre-heated oven of both 25±1 [℃] and 90±1 [℃]. And stress-strain of specimens was measured by TENSOMETER 2000. A speed of measurement was 200[mm/min], ranges of stress and strain were 400[Kgf/㎠] and 600[%]. In addition tests of stress-strain were progressed by aging specimens in air oven. From this experimental results, volume resistivity was high according to increasing the content of carbon black. And yield stress was increased, while strain was decreased according to increasing the content of carbon black. And stress-strain were decreased some after aging because of oxidation reaction of chemical defect. We could know EEA was excellent more than other specimens from above experimental results.

Pulse-Mode Dynamic Ron Measurement of Large-Scale High-Power AlGaN/GaN HFET

  • Kim, Minki;Park, Youngrak;Park, Junbo;Jung, Dong Yun;Jun, Chi-Hoon;Ko, Sang Choon
    • ETRI Journal
    • /
    • v.39 no.2
    • /
    • pp.292-299
    • /
    • 2017
  • We propose pulse-mode dynamic $R_on$ measurement as a method for analyzing the effect of stress on large-scale high-power AlGaN/GaN HFETs. The measurements were carried out under the soft-switching condition (zero-voltage switching) and aimed to minimize the self-heating problem that exists with the conventional hard-switching measurement. The dynamic $R_on$ of the fabricated AlGaN/GaN MIS-HFETs was measured under different stabilization time conditions. To do so, the drain-gate bias is set to zero after applying the off-state stress. As the stabilization time increased from $ 0.1{\mu}s$ to 100 ms, the dynamic $R_on$ decreased from $160\Omega$ to $2\Omega$. This method will be useful in developing high-performance GaN power FETs suitable for use in high-efficiency converter/inverter topology design.

Power spectra of wind forces on a high-rise building with section varying along height

  • Huang, D.M.;Zhu, L.D.;Chen, W.
    • Wind and Structures
    • /
    • v.18 no.3
    • /
    • pp.295-320
    • /
    • 2014
  • The characteristics of amplitudes and power spectra of X axial, Y axial, and RZ axial (i.e., body axis) wind forces on a 492 m high-rise building with a section varying along height in typical wind directions are studied via a rigid model wind tunnel test of pressure measurement. Then the corresponding mathematical expressions of power spectra of X axial (across-wind), Y axial (along-wind) and torsional wind forces in $315^{\circ}$ wind directions are proposed. The investigation shows that the mathematical expressions of wind force spectra of the main structure in across-wind and torsional directions can be constructed by the superimposition of an modified wind spectrum function and a peak function caused by turbulent flow and vortex shedding, respectively. While that in along-wind direction can only be constructed by the former and is similar to wind spectrum. Moreover, the fitted parameters of the wind load spectra of each measurement level of altitude are summarized, and the unified parametric results are obtained. The comparisons of the first three order generalized force spectra show that the proposed mathematical expressions accord with the experimental results well.

Quality Measurement of Data Processing by a Protocol Change of Power SCADA System (전력감시제어설비의 프로토콜 변경에 따른 데이터처리 품질측정)

  • Lee Yong-Doo;Choi Seong-Man;Yoo Cheol-Jung;Chang Ok-Bae
    • The KIPS Transactions:PartD
    • /
    • v.12D no.7 s.103
    • /
    • pp.1031-1038
    • /
    • 2005
  • In this paper, the maximum traffic quantity and actual traffic quantify of the data which are needed to grasp the statement of a system will be measured more accurately. A concrete quality measurement will be conducted by analysing a change of traffic quantity according to a protocol change and traffic under an overload condition when there is an accident. As a result can make an opportunity to maximize safety of power SCADA. Furthermore, future traffic quantity can be prospected by knowing current traffic quantity and grasping the rate of increase by the analysis and the information can be used as data to secure the band width in advance. It can make stable operation of power SCADA by arranging the limited network resources efficiently by information analysis of a network and expects more confidence.