• Title/Summary/Keyword: Power Measurement

Search Result 4,630, Processing Time 0.036 seconds

Measurement and Analysis of Surges on Information Devices Installed in a Power Substation (변전소내 정보기기에서 서지의 측정과 분석)

  • Song Jae-yong;Park Dae-won;Seo Hwang-dong;Han Joo-sup;Kil Gyung-suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.2
    • /
    • pp.289-294
    • /
    • 2005
  • This paper deals with the analysis results of surge voltage and current measured on information devices installed in a power substation. The power recorder to measure surge voltage and current was connected to signal lines near power transformers and switches, and the time resolution of the power recorder is 4 MS/s. Peak value of the measured surge voltage and current were ranges of 500~1,300v and 500~3,100k, respectively. During the period of measurement, over 5~10 events per day were recorded. Consequently, information devices installed in around high voltage power facilities should be designed considering the surge voltage and current caused in the condition.

Study on Influences and Elimination of Test Temperature on PDC Characteristic Spectroscopy of Oil-Paper Insulation System

  • Liu, Xiao;Liao, Ruijin;Lv, Yandong;Liu, Jiefeng;Gao, Jun;Hao, Jian
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1107-1113
    • /
    • 2015
  • Test temperature is an important factor affecting the measurement results of dielectric response of field power transformers. In order to better apply the polarization and depolarization current (PDC) to the condition monitoring of oil-paper insulation system in power transformers, the influences and elimination method of test temperature on PDC characteristic spectroscopy (PDC-CS) were investigated. Firstly, the experimental winding sample was measured by PDC method at different test temperatures, then the PDC-CS was obtained from the measurement results and its changing rules were discussed, which show that the PDC-CS appears a horizontal mobility with the rise of temperature. Based on the rules, the “time temperature shift technique” was introduced to eliminate the influence of test temperature. It is shown that the PDC-CS at different test temperatures can be converted to the same reference temperature coincident with each other.

The Effects of Electrical Therapy and Kinesio Taping on the Grip Strength and Pain in Tennis Elbow Patients (전기치료와 키네시오 테이핑 요법이 테니스 엘보 환자의 통증과 악력에 미치는 영향)

  • Lee, Kwang jae
    • Journal of Korean Physical Therapy Science
    • /
    • v.21 no.1
    • /
    • pp.53-58
    • /
    • 2014
  • Background : The purpose of this study is to identify the level of positive influence on the pain and the gripping power in patients with tennis elbow by comparing the TENS treatment method and the kinesio taping therapy with good accessibility among the kinesio taping therapy and electrical therapy. Methods : Targeting the patients diagnosed with tennis elbow, the subjects were categorized in groups of four, each of electrical therapy group and kinesio tape therapy group where the degree of pain reduction through VAS before and after the treatment of each group and the measurement of the degree of gripping power increase using the gripping power measurement tool as well as the pain reduction changes and gripping power increase before and after the treatment between the two groups were compared. Result : As a result, the electrical therapy group and the kinesio tape group were able to obtain the results of pain reduction and gripping power increase through VAS before and after the treatment, but for all pain reduction and gripping power increase, it had no statistically significant changes(p>.05). In addition, in the changes of pain reduction and changes of gripping power increase before and after the treatment, there were no statistically significant differences between the electrical therapy group and the kinesio tape group(p>.05). Conclusion : Based on the results so far, it is thought that the kinesio taping therapy can positively influence the pain reduction of patients with tennis elbow and increase of gripping power.

  • PDF

Confinement Effect Analysis Of Suction Pile In Ground Soil On The Basis Of Natural Frequency Measurement (고유진동수 기반 석션기초의 지반구속효과 분석)

  • Ryu, Moo Sung;Lee, Jun Shin;Lee, Jong Hwa;Seo, Yun Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.31-36
    • /
    • 2022
  • This paper presents the measuring process of dynamic properties of offshore wind power foundation and provides consideration of each step. This Guideline enables to maintain consistent measuring procedure and therefore increase the reliability of test results. Small scaled suction bucket foundation was fabricated to represent the commercial support structure installation mechanism and two cases(free-free, free-fixed) of dynamic tests were performed at workshop. From the tests, the importance of dynamic properties of connection part between suction bucket and tower was figured out. More over, types and configuration of measuring devices are recommended which can help find the natural frequency of wind turbine foundation correctly. In field test, it was found that the natural frequency of suction bucket foundation was increased linearly with the penetration depth due to the confining effect of ambient soil. Meanwhile, it was not easy to get an enough excitation force with normal impact hammer because the N.F of suction bucket model was in the lower range of 0 Hz ~ 5 Hz. Therefore, new excitation method which has enough force and can excite lower frequency range was devised. This study will help develop safety check procedure of suction bucket foundation in field at each installation stage using the N.F measurement.

Bad Data Detection Method in Power System State Estimation (전력계통 상태 추정에서의 불량정보 검출기법)

  • Choi, Sang-Bong;Moon, Young-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.239-243
    • /
    • 1990
  • This paper presents a algorithm to improve accuracy and reliability in state estimation of contaminated bad data. The conventional algorithms for detection of bad data confront the problems of excessive memory requirements and long computation time. In order to overcome measurement compensation approach is proposed to reduce computation time and partitioned measurement error model has the advantage of remarkable reduction in computation time and memory requirements in estimated error computation. The proposed algorithm has been tested for IEEE sample systems, which shows its applicability to on-line power systems.

  • PDF

A Study on the Ultrasonic Measurement for Damage Evaluation of Power Plant Bearing (발전용 베어링 손상평가를 위한 초음파 측정 연구)

  • Lee, Sang-Guk
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1727-1732
    • /
    • 2004
  • For the purpose of monitoring by ultrasonic test of the ball bearing conditions in rotating machinery, a system for their diagnosis was developed. ultrasonic technique is used to detect abnormal conditions in the bearing system. And various data such as frequency spectrum, energy and amplitude of ultrasonic signals, and ultrasonic parameters were acquired during experiments with the simulated ball bearing system. Based on the above results and practical application for power plant, algorithms and judgement criteria for diagnosis system was established.

  • PDF

Harmonics Measurement and Analysis for Korea High Speed Train Prototype (한국형 고속전철 시제차량 고조파 계측 및 분석)

  • Lee Tae-Hyung;Park Choon-Soo
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1415-1419
    • /
    • 2004
  • It is essential to evaluate harmonic characteristics of high speed train using power electronics equipment such as converter-driven motor drives, battery chargers and auxiliary power supplies. The purpose of this study is to measure and analyze harmonics characteristics of korea high speed train prototype. This paper presents result of harmonics measurement and analysis of harmonics characteristics in terms of loading, speed and operation mode.

  • PDF

Realtime Measurement of Power and Dynamic Resistance in Resistance Spot Welding (저항 점용접에서의 입열량과 동저항의 실시간 측정에 관한 연구)

  • 장희석;조승범
    • Proceedings of the KWS Conference
    • /
    • 2003.05a
    • /
    • pp.143-145
    • /
    • 2003
  • The purpose of research is to measure power and dynamic resistance value through RMS module. Specially designed RMS-DC hardware module was tested. Its output which is obtained every half cycle was compared with that of commercial weld checker. The results show good agreement and the relative error in the measurement was found to be around 5%.

  • PDF

Ghost and Blocking of TV signal by UHV Transmission Lines (대형 송전선로에 의한 TV 전파장해 고찰)

  • Shin, Koo-Yong;Lee, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1776-1778
    • /
    • 1998
  • KEPCO has been constructing the 765 kV double circuit transmission line since 1997. It is worried that the 765 kV transmission lines make TV interference(Ghost and Blocking) due to high tower and multi sub-conductors. This paper presents the mechanism, the measuring method and the results of TV ghost and blocking measurement using a new TV ghost measurement system in a vehicle which was developed by KEPRI.

  • PDF

Power System Voltage Stability Classification Using Interior Point Method Based Support Vector Machine(IPMSVM)

  • Song, Hwa-Chang;Dosano, Rodel D.;Lee, Byong-Jun
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.9 no.3
    • /
    • pp.238-243
    • /
    • 2009
  • This paper present same thodology for the classification of power system voltage stability, the trajectory of which to instability is monotonic, using an interior point method based support vector machine(IPMSVM). The SVM based voltage stability classifier canp rovide real-time stability identification only using the local measurement data, without the topological information conventionally used.