• Title/Summary/Keyword: Power Measurement

Search Result 4,625, Processing Time 0.033 seconds

A Novel Receiver Sensing Scheme for Capacitive Power Transfer System (전계결합 무선전력전송의 수신부 감지 방법)

  • Jeong, Chae-Ho;Im, Hwi-Yeol;Choi, Sung-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.1
    • /
    • pp.62-65
    • /
    • 2019
  • Wireless power transfer systems require an algorithm to determine the presence of the target object for mitigating standby power and safety issues. Although many schemes that sense various external objects have been actively proposed for inductive power transfer systems, not many studies on capacitive power transfer systems have been conducted compared with those on inductive power transfer systems. This study proposes a target object detection algorithm by monitoring the capacitance in transmitter-side electrodes without additional pressure sensors or distance sensors. The proposed algorithm determines the presence of a target object by monitoring the change in capacitance in transmitter-side electrodes using the step pulse of the microcontroller unit. The algorithm is verified by two step processes. First, the performance in capacitance measurement is compared with that of an LCR meter. Then, the verification is conducted in a 5-W capacitive power transfer hardware. Experimental result shows that the interelectrode capacitance increases by 6 times when the target object is fully aligned. Thus, the proposed scheme can successfully detect the presence of the target object.

Wattmeter for Voltage, Current, Power and Power Factor Measurement (정밀전압, 전류, 전력, 역률측정 전력계)

  • Park, Y.T.;Yu, K.M.;Ryu, K.S.;Kim, H.J.;Jang, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.625-627
    • /
    • 2002
  • High precision voltages. currents. power factor and electrical power measurements wide range of frequency can be achieved by using the thermo-elements (thermal converters). This paper describes the development wattmeter. based on a thermal principle. The instrument has been performed measurement in the range of currents from 0 to 50 A, voltages up to 600 V, power factor 0.5. 1 and frequencies from 45 Hz to 3 kHz. The thermal converters with two heater are used in the functional element of the wattmeter.

  • PDF

Effective Measurement and modeling of memory effects in Power Amplifier (RF 전력 증폭기 메모리 효과의 효율적인 측정과 모델링 기법)

  • Kim, Won-Ho;HwangBo, Hoon;Nah, Wan-Soo;Park, Cheon-Seok;Kim, Byung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.261-264
    • /
    • 2004
  • In this paper, we identify the memory effect of high power(125W) laterally diffused metal oxide-semiconductor(LDMOS) RF Power Amplifier(PA) by two tone IMD measurement. We measure two tone IMD by changing the tone spacing and the power level. Different asymmetric IMD is founded at different center frequency measurements. We propose the Tapped Delay Line-Neural Network(TDNN) technique as the modeling method of LDMOS PA based on two tone IMD data. TDNN's modeling accuracy is highly reasonable compared to the memoryless adaptive modeling method.

  • PDF

Power disturbance measurement system using discrete wavelet transform (이산웨이블릿을 이용한 전력외란 측정 시스템)

  • Lee J.M.;Kim H.G.;Choi J.H.;Lee S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.177-181
    • /
    • 2003
  • Need of power stability, reliability is increased, as using of sensitive: nonlinear load are increasing. Therefore, Power Quality Problems become the center of public interest. Many kinds of algorithms have been studied for monitoring of Power Quality Problems. Monitoring algorithms of using RMS, FT and the others are easy to applicate to system. But, it is not enough to monitor all of Foyer. Quality problems. Wavelet Transform is more proper to applicate. so, This paper presents measurement system using discrete wavelet transform.

  • PDF

Partial Discharge Electromagnetic Wave Penetration Characteristics Throughout Transformer Winding (전자기파 부분방전 신호의 권선 투과 특성)

  • Ju, Hyung-Jun;Han, Ki-Son;Yoon, Jin-Yul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.809-813
    • /
    • 2010
  • Frequency domain measurement of propagation loss for ultra high frequency (UHF) partial discharge in the winding of power transformer using a spectrum analyzer and pulse generator is presented. We compared the performance of the method using a network analyzer with and without a winding. Using a network analyzer simplifies the measurement and offers better dynamic range and frequency range. It also provides precise propagation loss within the winding in frequency domain at UHF range. We applied this method to measure UHF propagation loss of transformer mock-up, modeled 154 kV 20 MVA power in KEPCO substation.

Research for Installation and Operation of High Temperature Superconducting Cable System (고온 초전도 케이블 시스템 설치 밀 운전을 위한 연구)

  • Choi, Hyung-Sik;Sohn, Song-Ho;Hwang, Si-Dole
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.653-657
    • /
    • 2005
  • The commercial contract was made firstly in the world for one set of high temperature superconducting(HTS) cable system between buyer, Korea Electric Power Research Institute and seller, Sumitomo Electric Industries, Ltd. in August 2004. After fabrication, test and examination, the HTS cable system will be installed at the KEPRI's test field in Gochang, Jeonbuk province from the time of July 2005. KEPRI is preparing measurement and test facilities for field test of the HTS cable system and carrying out researches into the design and construction of superconducting cable test building, evaluation of cooling performance, measurement of AC loss, analysis of the quench phenomena due to excess current and means of linking the HTS cable system to the existing electric power supplying system. The constitution of, the method to install and the plan of test operation of the HTS cable system will be presented in this paper.

  • PDF

A Study on the Periodic Surveillance Algorithm for the Nuclear Power Plant Protection System (발전소 보호계통 주기적 점검 알고리즘에 관한 연구)

  • Park, Jong-Beom;Cho, Whang
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.201-203
    • /
    • 2001
  • Safety is emphasized in nuclear power plant system for its characteristic. One of the most important systems to guarantee the safety of nuclear power plant is the PPS(Power protection system). The measurement control system includes PPS, which is similar to the human nervous system, is very important factor not only for the safety but also for the operation. Therefore, developing a technology to level up the performance of measurement system and reliability of the plant will bring cost-effective and safe generation of nuclear power. In this study, I researched composition of digitized PPS and algorithm for cyclic inspection.

  • PDF

Effects of Hot Water on the Aging of URD Power Cables (지중 배편케이블의 열화에 미치는 온수의 영향)

  • 한재홍;송일근;김주용;이병성;정종욱
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.7
    • /
    • pp.609-614
    • /
    • 2002
  • In this study, we investigated the effects of hot water on the aging of URD power cables due to the hot water ingress to power distribution lines. Hot water contacted and non-contacted cables extracted from 2 distribution lines were characterized by the measurement of oxidation induction time(OIT) and chemical structure. In OIT measurement, hot water contacted cables showed the shorter OIT than non-contacted ones. Especially, hot water contacted insulation layer near insulation shield showed the shortest OIT. In chemical structure analysis, the antioxidant content was decreased and the acid concentration was increased by hot water ingress. From this results, it can be concluded that the hot water ingress to power cable may be accelerate the aging by means of antioxidant consumption.

Comparison of The Attenuation Measurement Methods for Electromagnetic Partial Discharge Signal in 25.8 kV Gas Insulated Switchgear (25.8 kV GIS에서 전자기파 부분방전신호 감쇠특성 측정방법 비교)

  • Goo, Sun-Geun;Han, Ki-Sun;Kwak, Joo-Sik;Joo, Hyung-Jun;Jeong, Moon-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1281-1287
    • /
    • 2015
  • We report the characteristics and differences of two types of attenuation measurement methods for electromagnetic partial discharge signal in GIS. The pulse method is to measure the attenuated waveforms in time domain and coverts them into frequency domain to get the attenuation spectra of given GIS section. This method simulates the real partial discharge signal. The frequency swept continuous wave method can obtain attenuation spectra directly so that it gives attenuation with low noise floor and simplicity. We show that both methods are effective and exchangeable because the attenuation results measured by two methods have similar trends

Analysis on Induction Watthour Meter Performance With Frequency Variation (유도형 적산전력량계의 주파수 변화 특성해석)

  • Jang, S.M.;Lee, S.H.;Seo, J.H.;Jeong, S.S.;Park, Y.T.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.25-27
    • /
    • 1997
  • The precise measurement of consumed power for a given time is very important in the energy management aspect. Up to days, most power meter has been used and designed for use on circuits in which the voltage and current are essentially sinusoidal. Recently the increase of switching element in power system causes the current and voltage with harmonics. Therefore, power energy involving harmonics is supplied to the system and the error of power measurement of watthour meter is existed. In this paper, we present a characteristic analysis by input frequency variation and analytical basis of induction watthour meter considering harmonics.

  • PDF