• Title/Summary/Keyword: Power Island

Search Result 473, Processing Time 0.032 seconds

Technical Problems and solution based on Connection of Ullung Wind Power Plant into Power Distribution System (울릉도 풍력발전 계통연계 문제점 및 대책)

  • Yoon, G.G.;Lee, W.S.;Kim, B.H.;Lee, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.305-307
    • /
    • 2001
  • The wind power equipment of Ullung island is composed of a hybride type of wind powers and diesel generators. The wind power generation in Ullung island is, howerever, not smooth due to the small capacity and weekness of existing power systems and line. Therefore, it is the purpose of this study to describe the technical problems and its solution through the investigation of actual conditions.

  • PDF

Renewable Energy Configuration Plan of Micro Grid in Gapa Island (가파도 마이크로그리드 신재생 에너지 전원 구성 방안)

  • Kim, Dong-Wan;Ko, Ji-Han;Kim, Seong Hyun;Kim, Homin;Kim, Eel-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.2
    • /
    • pp.16-23
    • /
    • 2014
  • This paper presents a renewable energy configuration plan of Micro grid in Gapa Island. To analyze the characteristics of Micro grid, BESS (Battery Energy Storage System), PMSG (Permanent Magnet Synchronous Generator) and SCIG (Squirrel Cage Induction Generator) are first modelled. The PMSG and SCIG will operate with basis on the real power curve. when the total power demand is larger than the total power generation, the BESS will be operated and the SOC (State Of Charge) is reduced. If the value of SOC could drop down to limited value, the system may be broken because of the voltage drop of BESS. To solve this problem, a DG (Diesel Generator) is used to charge the BESS and keep the voltage value of BESS with in a allowance limit. This paper represents simulation result when PMSG, SCIG connected to the Micro grid installed in Gapa Island. The simulation is carry out by using PSCAD/EMTDC program with actual line constant and transformer parameter in Gapa Island.

A Study on Estimation of Capacity Value for Renewable Generation in Jeju-Island (제주 계통 신재생 발전 자원의 유효 공급능력 추정에 관한 연구)

  • Wi, Young-Min
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.469-473
    • /
    • 2019
  • In the case of renewable generation resources, the supply capacity is determined by the climate and environment factors unlike the existing generators. Therefore, it is necessary to calculate the capacity vlaue for estimating the supply capacity of renewable generation sources. In this paper, a case study on the estimation method of capacity vlaue of renewable generation resources and a verification using data of Jeju-Island power system are presented. This paper is different from the existing researches because of estimating the capacity value of renewable generation resources for the Jeju-Island power system, which has a high ratio of renewable generation.

A Study on Estimation of Wind Power Generation using Weather Data in Jeju Island (기상관측자료를 이용한 제주도 풍력단지의 풍력발전량 예측에 관한 연구)

  • Ryu, Goo-Hyun;Kim, Ki-Su;Kim, Jae-Chul;Song, Kyung-Bin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2349-2353
    • /
    • 2009
  • Due to high oil price and global warming of the earth, investments for renewable energy have been increased a lot continuously. Specially, wind power has been received a great attention in the world. In order to construct a new wind farm, forecasting of wind power generation is essential for a feasibility test. This paper investigates wind velocity measurement data of Gosan weather station which located in Hankyung of Jeju island. This paper presents results of estimation of wind power generation using digital weather forecast provided from Korea meteorological administration, and the accuracy of the wind power forecasting by comparison between forecasted data and actual wind power data.

An Economic Feasibility Study of Wind-Diesel Hybrid Power Systems for an Island in the Yellow Sea (서해 도서지역의 풍력-디젤 하이브리드 발전에 대한 경제성 분석)

  • Lee, Tak-Kee;Nam, Yong-Yun;Kim, Jae-Dong;Han, Jeong-Woo
    • Journal of Navigation and Port Research
    • /
    • v.35 no.5
    • /
    • pp.381-385
    • /
    • 2011
  • In this paper, an economic feasibility study of wind-diesel hybrid power systems for an island in the Yellow Sea, where the maximum power generation is about 500kW, was performed. For the study, annual electric load variation and wind resource data of the island were collected and analyzed. HOMER program - a typical hybrid optimization model for electric renewables including wind resource, developed by the National Renewable Energy Laboratory - was used. Wind speed and diesel price were picked out as variables for the sensitivity analysis in order to find the economic accountability for the wind-diesel hybrid power system. As the result, even though it is not feasible economically under the present condition, if mean wind speed is over 3 m/sec. or diesel price goes up to 2.4 $ per liter, the wind-diesel hybrid power system for the island becomes a prospective candidate.

Dynamic Economic Dispatch and Control of a Stand-alone Microgrid in DongAo Island

  • Ma, Yiwei;Yang, Ping;Guo, Hongxia;Wang, Yuewu
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1432-1440
    • /
    • 2015
  • A dynamic economic dispatch and control method is proposed to minimize the overall generating cost for a stand-alone microgrid in DongAo Island, which is integrated with wind turbine generator, solar PV, diesel generator, battery storage, the seawater desalination system and the conventional loads. A new dispatching strategy is presented based on the ranking of component generation costs and two different control modes, in which diesel generator and battery storage alternate to act as the master power source to follow system power fluctuation. The optimal models and GA-based optimization process are given to minimize the overall system generating cost subject to the corresponding constraints and the proposed dispatch strategy. The effectiveness of the proposed method is verified in the stand-alone microgrid in DongAo Island, and the results provide a feasible theoretical and technical basis for optimal energy management and operation control of stand-alone microgrid.

Autonomous Micro-grid Design for Supplying Electricity in Carbon-Free Island

  • Hwang, Woo-Hyun;Kim, Sang-Kyu;Lee, Jung-Ho;Chae, Woo-Kyu;Lee, Je-Ho;Lee, Hyun-Jun;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.1112-1118
    • /
    • 2014
  • In island and backcountry areas, electrical power is usually supplied by diesel generators. It is difficult for small scale diesel generators to have an economy of scale owing to the usage of fossil fuels to produce electricity. Also, there is a problem of carbon dioxide emissions that brings some environmental pollution to the entire region of the area. For solving those, this paper proposes a design method of autonomous micro-grid to minimize the fossil fuels of diesel generator, which is composed of diesel generator, wind turbine, battery energy storage system and photovoltaic generation system. The proposed method was verified through computer simulation and micro-grid operation system.

Frequency and Voltage Control Strategies of the Jeju Island Power System Based on MMC-HVDC Systems

  • Quach, Ngoc-Thinh;Chae, Sang Heon;Song, Seung-Ho;Kim, Eel-Hwan
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.204-211
    • /
    • 2018
  • At present, one of two LCC-HVDC systems is responsible for controlling the grid frequency of the Jeju Island Power System (JIPS). The grid voltage is regulated by using STATCOMs. However, these two objectives can be achieved in one device that is called by a modular multilevel converter-high voltage direct current (MMC-HVDC) system. Therefore, this paper proposes frequency and voltage control strategies for the JIPS based on a MMC-HVDC system. In this case, the ancillary frequency and voltage controllers are implemented into the MMC-HVDC system. The modelling of the JIPS is done based on the parameters and measured data from the real JIPS. The simulation results obtained from the PSCAD/EMTDC simulation program are confirmed by comparing them to measured data from the real JIPS. Then, the effect of the MMC-HVDC system on the JIPS will be tested in many cases of operation when the JIPS operates with and without STATCOMs. The objective is to demonstrate the effectiveness of the proposed control strategy.

Improved RPV(reactive-power-variation) anti-islanding method for grid-connected three-phase PVPCS (3상 계통연계형 태양광 PCS의 단독운전검출을 위한 개선된 무효전력변동기법)

  • Lee, K.O.;Jung, Y.S.;So, J.H.;Yu, B.G.;Yu, G.J.;Choi, J.Y.;Choy, I.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1159-1160
    • /
    • 2006
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, this has raised potential problems of network protection on electrical power system. One of the numerous problems is an Island phenomenon. There has been an argument that because the probability of islanding is extremely low it may be a non-issue in practice. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an island can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficient to cause a trip, plus the time required to execute the trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. And, third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an island. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. So the verification of anti-islanding performance is strongly needed. In this paper, the authors propose the improved RPV method through considering power quality and anti-islanding capacity of grid-connected three-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation and experimental results are verified.

  • PDF

The Impact of VSC-HVDC Connected an Offshore Wind Power in Voltage Distribution of the AC Power System (해상풍력 연계용 전압형 HVDC가 AC 전력계통의 전압 분포에 미치는 영향)

  • Ban, Seung-Gil;Huh, Jae-Sun;Kang, Byoung-Wook;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.237-238
    • /
    • 2015
  • This paper analyzed the impact of Voltage Sourced Converter High Voltage Direct Current(VSC HVDC) connected an offshore wind power on the Jeju Island electrical power system. Wind power output fluctuates with the changing of wind speed. By changing wind power output occupancy into 100%, 60%, 10% respectively, we can understand the bus voltage distribution controlled by VSC HVDC. PSS/E is used to analyze steady-state simulation results which show effectiveness of the VSC HVDC for Jeju Island power system.

  • PDF