• 제목/요약/키워드: Power Generator

검색결과 3,834건 처리시간 0.028초

Power Management of Open Winding PM Synchronous Generator for Unbalanced Voltage Conditions

  • EL-Bardawil, Ashraf;Moussa, Mona Fouad
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2192-2201
    • /
    • 2016
  • Wind energy is currently the fastest-growing electricity source worldwide. The cost efficiency of wind generators must be high because these generators have to compete with other energy sources. In this paper, a system that utilizes an open-winding permanent-magnet synchronous generator is studied for wind-energy generation. The proposed system controls generated power through an auxiliary voltage source inverter. The VA rating of the auxiliary inverter is only a fraction of the system-rated power. An adjusted control system, which consists of two main parts, is implemented to control the generator power and the grid-side converter. This paper introduces a study on the effect of unbalanced voltages for the wind-generation system. The proposed system is designed and simulated using MATLAB/Simulink software. Theoretical and experimental results verify the validity of the proposed system to achieve the power management requirements for balanced and unbalanced voltage conditions of the grid.

A Novel Three-Phase Four-Wire Grid-Connected Synchronverter that Mimics Synchronous Generators

  • Tan, Qian;Lv, Zhipeng;Xu, Bei;Jiang, Wenqian;Ai, Xin;Zhong, Qingchang
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2221-2230
    • /
    • 2016
  • Voltage and frequency stability issues occur in existing centralized power system due to the high penetration of renewable energy sources, which decrease grid absorptive capacity of them. The grid-connected inverter that mimics synchronous generator characteristics with inertia characteristic is beneficial to electric power system stability. This paper proposed a novel three-phase four-wire grid-connected inverter with an independent neutral line module that mimics synchronous generators. A mathematical model of the synchronous generator and operation principles of the synchronverter are introduced. The main circuit and control parameters design procedures are also provided in detail. A 10 kW prototype is built and tested for further verification. The primary frequency modulation and primary voltage regulation characteristics of the synchronous generator are emulated and automatically adjusted by the proposed circuit, which helps to supports the grid.

정수장 마이크로 소수력 발전기 적용에 대한 연구 (A Study on the Application of Micro Hydro Power Generator at the Water Treatment Plant)

  • 김종겸;박영진;김일중
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.67-72
    • /
    • 2014
  • Inflow or outflow from the water treatment plant and the sewage water has potential energy. If this potential energy can be converted into electrical energy by water turbine generator, it can help to save energy because of the high capacity utilization. So recently, micro hydro power plant is reviewed in the water treatment facility. If generation capacity is low, induction generator is primarily used. If output capacity is low, generated power is supplied to the inside load. Induction generator can cause voltage drop by the inrush current at a start-up and requires reactive power for magnetization. In this study, we analyzed the flow of power and voltage variation against inrush current that occurs when the induction generator starts under the terms that loads of linear and non-linear of the water purification plant are used. Analysis results are that the voltage drop is within an allowable range and the power factor is slightly reduced by the need of reactive power.

혼합형 디지털 자동 전압 조정 장치를 이용한 선박용 동기발전기의 출력전압제어 (Voltage Control of a Synchronous Generator for Ship using a Compound Type Digital AVR)

  • 박상훈;이상석;유재성;이수원;원충연
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.397-403
    • /
    • 2009
  • In this paper, an exciter current control of a synchronous generator for ships using a compound type digital automatic voltage regulator (DVAR) in order to provide a constant output voltage of the generator is presented. The compound type DAVR is composed of a controller part to adjust output voltage and an power source unit to supply power to the exciter. The controller part, which generates the PWM switching pattern via the PI controller, drives a power MOSFET for bypass to limit the SG's exciter current. The power source unit part is parallel connected to an output terminal of the generator through a reactor and a power CT. The residual magnetic flux of SG provides exciter current to the exciter through the reactor during the initial running or no load state and load current supplies field current to the exciter through the power CT during loading state. This paper confirmed an experiment to verify the validity of compound type DAVR system for controlling output voltage of synchronous generator.

엔진 시동용 소형선 탑재형 파력 발전 시스템 (The Wave Power Generator on Small Ship for Charging Engine Start-Up Battery)

  • 류기수;강성진;유병석
    • 대한조선학회논문집
    • /
    • 제59권6호
    • /
    • pp.439-446
    • /
    • 2022
  • Efforts to reduce carbon dioxide(CO2) emissions are being carried out due to climate environmental problems. Eco-friendly ships are also being developed, and various energy saving measures have been developed and applied. In ships, researches have been conducted in various fields such as electric propulsion system and energy saving devices. In addition, the development of ships using various renewable energy, such as kite using wind power and wind power generation, has been carried out. This paper proposes a plan to use renewable energy for ships by applying wave generators to small ships. In 2016, 130 small domestic ships drifted by sea due to discharge of starting storage batteries, and discharge cases accounted for the largest portion of the causes of domestic ship accidents. This is due to the excessive use of storage batteries for starting the main engine by departing in a weak storage battery state for small ships. Accordingly, two type wave power generators - opened flow wave power generator and enclosed vibrator type wave power generator - are developed for charging a starting storage battery when the ships are stationary at sea or port. Opened flow wave power generator utilizes the flow of fluid in the ship by using wave induced ship motion. Enclosed vibrator type wave power generator utilizes the pendulum kinetic energy located in a ship due to wave induced ship motion.

수소연소 선형 발전기의 초기 기동 (Starting operation of a linear generator driven by a hydrogen engine)

  • 정승기;김경수;최준영;오시덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.110-112
    • /
    • 2008
  • A linear generator driven by a hydrogen combustion engine has been developed. Unlike rotary engine-generator systems, the linear counterpart is inherently unable to start by itself unless external force is provided for initial compression/ignition cycle. When the generator is connected to utility power lines through a bidirectional power conversion system, however, the self start-up can be done by driving the generator as a motor. This paper introduces a prototype 1kW linear hydrogen engine-generator system being developed and shows the self start-up is possible with proper motoring mode.

  • PDF

개선된 적응 예측 필터를 이용한 새로운 능동전력필터용 기준신호발생기 (Novel Reference Signal Generator for Active Power Filter Using Improved Adaptive Predictive Filter)

  • 배병열;김희중;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.212-216
    • /
    • 2003
  • The performance of active power filter depends on the inverter characteristic, the control method, and the accuracy of reference signal generator. The accuracy of reference generator is the most critical item to determine the performance of active power filter. This paper introduces a novel reference signal generator composed of improved adaptive predictive filter. The performance of proposed reference signal generator was verified by means of simulation with MATLAB. The simulation result confirm that the proposed reference signal generator can be utilized for the active power filter.

  • PDF

UWB 펄스전자파 발생용 원통형 Marx 펄스발생장치개발 (Coaxial Marx Type Pulse Generator for UWB EM Pulse)

  • 장용무;이상욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.121-121
    • /
    • 2010
  • As the industrial technology is getting higher, the pulsed power technology is required from various fields such as thermonuclear fusion energy sources, military applications, electric power distribution, and a variety of new specialized needs. This technology deals with the generation of very high power electromagnetic pulses through fast switching. We fabricated a pulsed power generator, named EMD pulse generator, by using Marx circuit with 200 kV high, 50 ns fast rise time. In this paper, we described about an effect of stray capacitance of coaxial Marx generator, EPG-AM200k, and a comparing the results of experiments and circuit analysis.

  • PDF

전력품질 개선장치를 위한 간단한 구조의 전압변동 발생기 (A simple structured voltage disturbance generator for power quality improving devices)

  • 이병철;최성훈;팽성환;노의철;김인동;전태원;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.552-554
    • /
    • 2005
  • This paper deals with a simple structured voltage disturbance generator for power quality improving devices. The proposed generator can be applied to the performance test of custom power devices. Voltage sag, swell, outage, unbalance and phase jump after outage are provided by the generator. The improving phase jump operating principle of the generator is described and analysed. The usefulness of the generator is verified through simulation.

  • PDF

직접 구동 AFPM 풍력발전기의 특성해석 (Characteristics Analysis of a Direct-Drive AFPM Generator)

  • 서영택;김형길;공정식;김철호;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.687-689
    • /
    • 2003
  • Recently, issues regarding environment and the diversification of dependence in oil are watched with keen interest. Wind power attracts most interest because of its high-energy efficiency with environment friendly functions. The paper discusses the development of a coreless axial-flux permanent magnet (AFPM) generator for a wind power system. Analyzed the Coreless AFPM generator by electromagnetic, and designed wind power generator with this. The 3 phase output of stator is rectified and fed to a common do link. The overall machine structure has high compactness and lightness, because of the lack of the iron core. The test results with a resistive load confirm the satisfactory operation of generator. Compared with conventional generator, the design has lower weight, lower Power loss and improved efficiency.

  • PDF