• Title/Summary/Keyword: Power Facility

Search Result 1,293, Processing Time 0.03 seconds

Earthquake hazard and risk assessment of a typical Natural Gas Combined Cycle Power Plant (NGCCPP) control building

  • A. Can Zulfikar;Seyhan Okuyan Akcan;Ali Yesilyurt;Murat Eroz;Tolga Cimili
    • Geomechanics and Engineering
    • /
    • v.35 no.6
    • /
    • pp.581-591
    • /
    • 2023
  • North Anatolian Fault Zone is tectonically active with recent earthquakes (Mw7.6 1999-Kocaeli and Mw7.2 1999-Düzce earthquakes) and it passes through Marmara region, which is highly industrialized, densely populated and economically important part of Turkey. Many power plants, located in Marmara region, are exposed to high seismic hazard. In this study, open source OpenQuake software has been used for the probabilistic earthquake hazard analysis of Marmara region and risk assessment for the specified energy facility. The SHARE project seismic zonation model has been used in the analysis with the regional sources, NGA GMPEs and site model logic trees. The earthquake hazard results have been compared with the former and existing earthquake resistant design regulations in Turkey, TSC 2007 and TBSCD 2018. In the scope of the study, the seismic hazard assessment for a typical natural gas combined cycle power plant located in Marmara region has been achieved. The seismic risk assessment has been accomplished for a typical control building located in the power plant using obtained seismic hazard results. The structural and non-structural fragility functions and a consequence model have been used in the seismic risk assessment. Based on the seismic hazard level with a 2% probability of exceedance in 50 years, considered for especially these type of critical structures, the ratios of structural and non-structural loss to the total building cost were obtained as 8.8% and 45.7%, respectively. The results of the study enable the practical seismic risk assessment of the critical facility located on different regions.

A development of reliability evaluation model for power plant fan pitch blade control actuator (발전설비 통풍기 날개각 제어작동기 신뢰성평가 모델 개발)

  • Son, Tae-Ha;Huh, Jun-Young
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3259-3263
    • /
    • 2007
  • This paper describes the proceedings of creating countermeasures after analysis and maintenance be able to conduct operation safely in a power plant. in order to operate the power plant in a stable and reliable way, the best condition of the govemor system can be maintained through the response characteristic analysis of the control device for the pitch blade control hydraulic actuator. The fan pitch blade control hydraulic actuator of a 500MW large-scale boiler is frequently operated under normal operation conditions. Common problems or malfunctions of the pitch blade control hydraulic actuators leads to the decline of boiler thermal efficiency and unexpected power plant trip. The inlet and outlet gas can be controlled by using the fan pitch blade control hydraulic actuator in order to regulate the internal pressure of the furnace and control the frequency in the power plant facility which utilizes soft coals as a power source.

  • PDF

A Study of Testbed for Power Facility Management using RFID/USN (RFID/USN을 이용한 전력설비관리 테스트베드에 관한 연구)

  • Lee Jung-Il;Yi Bong-Jae;Song Jae-Ju;Shin Jin-Ho;Kim Yung-Il
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.05a
    • /
    • pp.1427-1430
    • /
    • 2006
  • RFID(Radio Frequency IDentification)는 전파신호를 이용하여 사물의 정보를 주고 받을 수 있는 기술로서, 기존 바코드의 느린 인식속도, 인식율, 저장능력의 한계를 극복하여 사물의 정보화를 촉진함으로서 물류 유통분야에 혁신적인 변화를 가져올 기술로 주목받고 있으며, 유비쿼터스 환경에서 핵심기술로 활용될 것이다.[1] 2004년부터 파급효과가 큰 국방, 조달, 환경 등 12개 분야에서 시범사업이 추진되고 있으며, 최근 한국전산원을 중심으로 USN 응용 서비스 모델을 발굴하기 위하여 총 8개 과제를 추진하는 등 차세대 국가 기간 기술의 요소 기술로서 공급기반을 확충하고 수요활성화 기반을 구축함으로서 세계적 수준의 RFID/USN 인프라를 조기에 구축하기 위한 노력을 경주하고 있다.[2] 본 연구에서는 전력산업을 대상으로 RFID의 적용가능 대상을 분석하고, 테스트베드를 구축하여 RFID의 적용 가능성을 판단하고자 한다.

  • PDF

Study on the effects of lightning arrestors installment on a 154kV transmission system (154kV 송전선로용 피뢰기 현장 설치 효과 분석)

  • Choi, Han-Yeol;Min, Byeong-Wook;Park, Soon-Kyu;Lee, Bong-Hee;Kwak, Joo-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.9-11
    • /
    • 2008
  • Lightning has been identified as one of the leading causes of outages on transmission and distribution systems. To protect the transmission and distribution line from lightning, the transmission lightning arrestor can be the effective facility on the power system. This paper will discuss Gapped type Arresters application results by analysing effects of lightning arrestors on transmission and distribution line.

  • PDF

A Study on the Power Loss Monitoring Methods with AMI systems (지능형 원격검침시스템을 이용한 전력손실 감시방법에 대한 연구)

  • Myoung, No-Gil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.67-74
    • /
    • 2013
  • Major utilities have been focusing on R&D and nationwide business of AMI system which plays a vital role in SmartGrid whose concept is to maximize energy efficiency and optimize electric power facility management with exchanging real time information between utilities and consumers based on ICT technologies in power grid. In this paper, we suggest a power loss monitoring method using KEPCO's AMI system which is operating in fields and with the acquisition of AMI data and analyses verify the validation of a power loss monitoring method.

The Development and Operation of Autochanger for Prevention of PT Voltage Loss in HVDC Facility (HVDC 변환설비 PT전원 상실방지 자동절체기 개발 및 운영)

  • Jo, Gyu-Hong;Bae, Jung-Hyun;Kim, Do-Am;Lim, Hong-Bae;Chu, Kwang-Bok;Kim, Jai-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.123-125
    • /
    • 2006
  • 본 논문은 해남-제주간 직류송전설비(HVDC)의운영 중 변환설비 제어에 사용되는 PT전원 상실에 의한 설비 불시 정지의 해결 방안으로 한국전력공사에서 연구 개발 및 운영 중인 고속도 PT자동절체기에 관한 사항이다. 특히, PT전원 상실시 HVDC가 설비 정지되는 것을 예방하기 위해 반도체소자(TRIAC)를 이용한 고속도 PT 자동절체기를 개발하여 설비 신뢰성을 확보한 내용에 대하여 고찰하였다.

  • PDF

A Study on the voltage drop apportion rates of the distribution systems (배전 시스템의 전압 강하 분담률에 관한 연구)

  • Park, Sang-Man;Park, Chang-Ho;Jeong, Yeong-Ho;Choi, Jeong-Hwan;Kim, Choong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2597-2599
    • /
    • 2004
  • The high quality power is consisted with uniform frequence, no interruption and uniform voltage. In these components, the voltage of the distribution systems affects making economic distribution facility and improving power quality. This paper describes on the voltage apportion rates of the distribution systems in KEPCO.

  • PDF

A Study on the Diagnostic Algorithm for Arc Flash of Power Equipment (전력기기의 아크 플래시 진단 알고리즘에 관한 연구)

  • Lee, Deok-Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.7
    • /
    • pp.449-453
    • /
    • 2016
  • The amount of electrical energy has been increased with the rapid development of the industrial society. Accordingly, operating voltage of the power equipment and facility capacity are continuously increasing. Development trends of recent high-voltage electrical equipment are ultra high-voltage, large-capacity and compact. Early diagnosis of a failure of the power plant has been emerging as an important task as to supply high quality power to users. In this study, we have tried to develope an algorithm for distinguishing an arc fault signal generated in the power plant by using UV sensor.

Two-Paralleled PWM Power Amplifiers to Generate Highly Precise Gradient Magnetic Fields in MRI Systems

  • Watanabe, Shuji;Boyagoda, Prasanna;Takano, Hiroshi;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.569-574
    • /
    • 1998
  • This paper presents a two-paralleled 4 quadrant DC chopper type PWM power conversion circuit in order to generate a gradient magnetic field in the Magnetic Resonance Imaging (MRI) system. This power amplifier is connected in parallel with the conventional 4-quadrant DC chopper using IGBTs at their inputs/outputs to realize further high-power density, high speed current tracking control, and to get a low switching ripple amplitude in a controlled current in the Gradient Coils (GCs). Moreover, the power conversion circuit has to realize quick rise/fall response characteristics in proportion to various target currents in GCs. It is proposed in this paper that a unique control scheme can achieve the above objective. DSP-based control systems realize a high control facility and accuracy. It is proved that the new control system will greatly enlarge the diagnostic target and improve the image quality of MRI.

  • PDF

Modelling of Power Plant Fan Pitch Blade Control Actuator (전력설비 대용량 보일러 통풍기 날개각 제어 작동기 모델링)

  • Huh, J.Y.;Son, T.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.2
    • /
    • pp.28-33
    • /
    • 2007
  • In the power plant facility which use soft coal as a power source the fan pitch blade control hydraulic actuator is used to control the inlet and outlet gas to regulate the internal pressure of the furnace and control the frequence. Sometimes malfunctions of this equipment lead to the decline of boiler thermal efficiency and unexpected power plant trip. In order to localize the fan pitch blade control hydraulic actuator specially for the 500MW large scale boiler, Analysis and modelling of the system is carried out mathematically. The responses of the system are examined by using matlab simulation fur the variation of the major parameters in view of reverse engineering. Consequently the validity of the established parameters are examined.

  • PDF