• Title/Summary/Keyword: Power Equipment Diagnosis

Search Result 182, Processing Time 0.022 seconds

Specification-based Analog Circuits Test using High Performance Current Sensors (고성능 전류감지기를 이용한 Specification 기반의 아날로그 회로 테스트)

  • Lee, Jae-Min
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.10
    • /
    • pp.1260-1270
    • /
    • 2007
  • Testing and diagnosis of analog circuits(or mixed-signal circuits) continue to be a hard task for test engineers and efficient test methodologies to solve these problems are needed. This paper proposes a novel analog circuits test technique using time slot specification (TSS) based built-in current sensors (BICS). A technique for location of a fault site and separation of fault type based on TSS is also presented. The proposed built-in current sensors and TSS technique has high testability, fault coverage and a capability to diagnose catastrophic faults and parametric faults in analog circuits. In order to reduce time complexity of test point insertion procedure, external output and power nodes are used for test points and the current sensors are implemented in the automatic test equipment(ATE). The digital output of BICS can be easily combined with built-in digital test modules for analog IC test.

  • PDF

ESBL: An Energy-Efficient Scheme by Balancing Load in Group Based WSNs

  • Mehmood, Amjad;Nouman, Muhammad;Umar, Muhammad Muneer;Song, Houbing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.10
    • /
    • pp.4883-4901
    • /
    • 2016
  • Energy efficiency in Wireless Sensor Networks (WSNs) is very appealing research area due to serious constrains on resources like storage, processing, and communication power of the sensor nodes. Due to limited capabilities of sensing nodes, such networks are composed of a large number of nodes. The higher number of nodes increases the overall performance in data collection from environment and transmission of packets among nodes. In such networks the nodes sense data and ultimately forward the information to a Base Station (BS). The main issues in WSNs revolve around energy consumption and delay in relaying of data. A lot of research work has been published in this area of achieving energy efficiency in the network. Various techniques have been proposed to divide such networks; like grid division of network, group based division, clustering, making logical layers of network, variable size clusters or groups and so on. In this paper a new technique of group based WSNs is proposed by using some features from recent published protocols i.e. "Energy-Efficient Multi-level and Distance Aware Clustering (EEMDC)" and "Energy-Efficient Multi-level and Distance Aware Clustering (EEUC)". The proposed work is not only energy-efficient but also minimizes the delay in relaying of data from the sensor nodes to BS. Simulation results show, that it outperforms LEACH protocol by 38%, EEMDC by 10% and EEUC by 13%.

Estimation of Motor Deterioration using Pulse Signal and Insulation Resistance Measurement Algorithm (펄스 신호 및 절연저항 측정 알고리즘을 이용한 전동기 열화 추정)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.5
    • /
    • pp.111-116
    • /
    • 2022
  • The causes of motor burnout include overload, phase loss, restraint, interlayer short circuit, winding ground fault, instantaneous overvoltage, and the rotor contacting the stator, leading to insulation breakdown, leading to breakdown or electrical accidents. Therefore, equipment failure causes not only loss due to cost required for equipment maintenance/repair, but also huge economic loss due to productivity decrease due to process stop because the process itself including the motor is stopped. The current level of technology for diagnosing motor failures uses vibration, heat, and power analysis methods, but there is a limit to analyzing the problems only after a considerable amount of time has passed according to the failure. Therefore, in this paper, a device and algorithm for measuring insulation resistance using DC AMP signal was applied to an industrial motor to solve this problem. And by following the insulation resistance state value, we propose a diagnosis of deterioration and failure of the motor that cannot be solved by the existing method.

An autonomous control framework for advanced reactors

  • Wood, Richard T.;Upadhyaya, Belle R.;Floyd, Dan C.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.896-904
    • /
    • 2017
  • Several Generation IV nuclear reactor concepts have goals for optimizing investment recovery through phased introduction of multiple units on a common site with shared facilities and/or reconfigurable energy conversion systems. Additionally, small modular reactors are suitable for remote deployment to support highly localized microgrids in isolated, underdeveloped regions. The long-term economic viability of these advanced reactor plants depends on significant reductions in plant operations and maintenance costs. To accomplish these goals, intelligent control and diagnostic capabilities are needed to provide nearly autonomous operations with anticipatory maintenance. A nearly autonomous control system should enable automatic operation of a nuclear power plant while adapting to equipment faults and other upsets. It needs to have many intelligent capabilities, such as diagnosis, simulation, analysis, planning, reconfigurability, self-validation, and decision. These capabilities have been the subject of research for many years, but an autonomous control system for nuclear power generation remains as-yet an unrealized goal. This article describes a functional framework for intelligent, autonomous control that can facilitate the integration of control, diagnostic, and decision-making capabilities to satisfy the operational and performance goals of power plants based on multimodular advanced reactors.

A Study of the Method for External Noise Shielding using the GIS UHF Sensor Module Applied to the Partial Discharge Signal Sensitivity and Method of Frequency Transforming in the Internal GIS (GIS내부의 부분방전신호 감도개선 및 주파수변환기법에 의한 GIS UHF Sensor 모듈의 외부노이즈차폐기법에 관한 연구)

  • Lee, Seung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.728-732
    • /
    • 2010
  • GIS(Gas insulated switching gear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. Recently, because equipment of GIS was occurring problem of confidence used for a long time, partial discharge on-line diagnosis systems have been importantly recognized. Partial discharge (PD) detection is an effective means for monitoring and evaluation of dielectric condition of gas insulated system (GIS). The ultra-high-frequency (UHF) PD detection technique can detect and locate the PD sources inside GIS by detecting electromagnetic wave emitted from PD source. Therefore, real-time diagnostic system using UHF detection method has been developed for this application is being expanded gradually. However, the signal of partial discharge occurring in SF6 gas is very weak and susceptible to external noises which mainly consist of PD in air. Thus, it is important to distinguish the PD in SF6 gas more sensitively from the external noises. Unfortunately, these external noise signals and the partial discharge signals have very similar characteristics. Therefore, to solve this problem, we need the signal processing method for distinguish partial discharge signals with external noise signals for improvement of SNR(signal to noise ratio) and sensitivity. In this paper, we proposed internal signal processing method for removing external noise signals with built-in pre.amplifier and frequency conversion circuit.

Automobile Engine Diagnostic System by Current Monitoring to Self Motor (시동모터 전류 관찰에 의한 자동차엔진 압축압력 검사장치)

  • Hyun, Woong-Keun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.1
    • /
    • pp.93-100
    • /
    • 2017
  • Four-stroke cycles in an automobile engine are suction stroke, compression stroke, combustion stroke and exhaustion stroke. A normal operation of engine in compression and power stroke must be processed in optimal fuel-air pressure. In this paper we describe a development of measuring equipment for engine cylinder pressure with observing supply current to self motor(start motor). By comparing the current wave on pressure of the 4 or 6 cylinder in engine, a abnormal cylinder state will be found. The validity of the proposed measuring equipment was shown by experiment for real automobile.

An Electrical Installation Failure Signal Detection using Time-Energy Analysis (시간-에너지 분석을 이용한 전기설비 이상신호 검출)

  • Jee S. W.;Lee C. H.;Kim Ch. N.;Lee K. S.;Sim K. Y.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.2
    • /
    • pp.82-87
    • /
    • 2006
  • Most of electric accidents are happened in the place where activities are frequent by common people who has low electric knowledge. Also, accidents are increased in the low voltage electric equipment. So, it is increased to spread the dispersion or non-utility power generation system. It means that ordinary times observation is required for electric equipments by common people. This paper is studied for the diagnosis method of electric equipment that common people can diagnose easily Voltage is generally and exactly measured in the electric and electronic field. We suggest new analysis tools using only electric voltage. It is called the Time-Energy analysis. The Time-Energy analysis is as following First, divide measured voltage waves into same parts, Second, conducted FFT(Fast Fourier Transform) transform for each divided period, Finally, each results are reassembled after graphic treatment. We compared Time-Energy analysis with discharge form by tracking tester. As the result, tracking discharge processes distinguished clearly.

Radiation Quality Analysis of Diagnostic X-ray Equipment (진단용 X선 기기의 선질 분석)

  • Kim, Tae-Gon;Kim, Young-Pyo;Cheon, Min-Woo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.771-772
    • /
    • 2010
  • X-ray equipment used to diagnose a patient has a big defect of a patient's exposure to radiation caused in irradiating X-ray to the human body, ICRP restricts the permissible exposure dose of the human body. A number of studies has been proceeded to reduce these exposures. In this study the high voltage generator with inverter system, which is possible to increase the generation efficiency of X-ray and to control the precise output power was produced. Also, to minimize the ripple which is possible to occur in the direct voltage that is applied to X-ray tube the propagation rectification method was applied and the radiation reproducibility and properties were evaluated to use this for the diagnosis of patient.

  • PDF

Implementation of point-of-care platforms for rapid detection of porcine circovirus type 2

  • Chiao-Hsu Ke;Mao-Yuan Du;Wang-Ju Hsieh;Chiu-Chiao Lin;James Mingjuh Ting;Ming-Tang Chiou;Chao-Nan Lin
    • Journal of Veterinary Science
    • /
    • v.25 no.2
    • /
    • pp.28.1-28.11
    • /
    • 2024
  • Background: Porcine circovirus type 2 (PCV2) infection is ubiquitous around the world. Diagnosis of the porcine circovirus-associated disease requires clinic-pathological elements together with the quantification of viral loads. Furthermore, given pig farms in regions lacking access to sufficient laboratory equipment, developing diagnostic devices with high accuracy, accessibility, and affordability is a necessity. Objectives: This study aims to investigate two newly developed diagnostic tools that may satisfy these criteria. Methods: We collected 250 specimens, including 170 PCV2-positive and 80 PCV2-negative samples. The standard diagnosis and cycle threshold (Ct) values were determined by quantitative polymerase chain reaction (qPCR). Then, two point-of-care (POC) diagnostic platforms, convective polymerase chain reaction (cPCR, qualitative assay: positive or negative results are shown) and EZtargex (quantitative assay: Ct values are shown), were examined and analyzed. Results: The sensitivity and specificity of cPCR were 88.23% and 100%, respectively; the sensitivity and specificity of EZtargex were 87.65% and 100%, respectively. These assays also showed excellent concordance compared with the qPCR assay (κ = 0.828 for cPCR and κ = 0.820 for EZtargex). The statistical analysis showed a great diagnostic power of the EZtargex assay to discriminate between samples with different levels of positivity. Conclusions: The two point-of-care diagnostic platforms are accurate, rapid, convenient and require little training for PCV2 diagnosis. These POC platforms can discriminate viral loads to predict the clinical status of the animals. The current study provided evidence that these diagnostics were applicable with high sensitivity and specificity in the diagnosis of PCV2 infection in the field.

Characteristic of X-ray Equipment according to the Input Power Condition (입력전원의 변화에 따른 X선 기기의 특성평가)

  • Kim, Young-Pyo;Kim, Tae-Gon;Cheon, Min-Woo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.773-775
    • /
    • 2010
  • Diagnostic X-ray high voltage generator needs high voltage input power when operated, if electric power conditions are not suitable, could not use diagnostic X-ray high voltage generator or could not use normally by abnormal working. If diagnostic X-ray system operated with abnormally by electric power conditions, it cause of difficulty of patient diagnosis. And we used auxiliary power with battery to operate diagnostic X-ray high voltage generator without using normal electric power. We made one device after designing of new electric circuit and we compared normal power X-ray system with battery powered X-ray system by described method in this thesis. And then we found characteristic and efficiency of diagnostic X-ray high voltage generator by different input power condition.

  • PDF