• Title/Summary/Keyword: Power Distribution Systems

Search Result 1,306, Processing Time 0.026 seconds

BER DEGRADATION DUE TO THE PHASE NOISE SPECTRAL SHAPE IN LMDS SYSTEMS

  • Kim, Youngsun;Song, Jong-In;Kim, Kiseon
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.113-116
    • /
    • 2000
  • Phase noise of oscillator gives the performance degradation significantly when a high carrier frequency and low transmission rate are used. The BER(Bit Error Rates) degradation of QPSK(Quadrature Phase Shift Keying) transmission is analyzed with the oscillator phase noise level specified in downstream physical interface of LMDS(Local Multipoint Distribution Services) which is described in DAVIC(Digital Audio Visual Council). The model used for the phase noise is a power-law model. We also investigated the effects of the various transmission rates on system performance. For the transmission rate below 0.5 Mbps, the BER performance is severely degraded and we verified that the transmission rate, 20 Mbps, is adequate for the downstream of LMDS systems.

  • PDF

Fuzzy Hypothesis Test by Poisson Test for Most Powerful Test (최강력 검정을 위한 퍼지 포아송 가설의 검정)

  • Kang, Man-Ki;Seo, Hyun-A
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.6
    • /
    • pp.809-813
    • /
    • 2009
  • We want to show that the construct of best fuzzy tests for certain fuzzy situations of Poisson distribution. Due to Neyman and Pearson theorem, if we have ${\theta}_0$ and ${\theta}_1$ be distinct fuzzy values of ${\Omega}=\{{\theta}\;:\;{\theta}\;=\;{\theta}_0,\;{\theta}_1\}$ such that $L({\theta}_0\;:\;X)/L({\theta}_1\;:\;X)$ < k, then k is a fuzzy number. For each fuzzy random samples point $X\;{\subset}\;C$, we have most power test for fuzzy critical region C by agreement index.

Measurement of Resistance of Multi-Grounded System by Ground Current Measurement (접지전류 측정에 의한 다중 접지계통의 접지저항 측정)

  • 최종기;안용호;정길조;한병성;김경철
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.234-234
    • /
    • 2004
  • Measuring ground resistance has been a popular method of evaluation of the grounding electrode performance. If some portions of grounding electrodes are lost by corrosion, aging or other reasons, consequent deteriotation of the grounding performance would be resulted. It is one of the reasons why it is required to evaluate the performance of grounding systems regularly. However, in case of the electric facilities with multi-grounded system such as power substations with multi-grounded overhead ground wires and/or distribution line neutrals, it is practically difficult to disconnect neutrals or skywires from the substation grounding mesh for the ground resistance measurement. In this paper, a method for the grounding performance measurement of multi-grounded systems, which is based on the measuring ground current distributions, has been proposed. A field test results has shown the validity of the proposed test method.

Sensing of OFDM Signals in Cognitive Radio Systems with Time Domain Cross-Correlation

  • Xu, Weiyang
    • ETRI Journal
    • /
    • v.36 no.4
    • /
    • pp.545-553
    • /
    • 2014
  • This paper proposes an algorithm to sense orthogonal frequency-division multiplexing (OFDM) signals in cognitive radio (CR) systems. The basic idea behind this study is when a primary user is occupying a wireless channel, the covariance matrix is non-diagonal because of the time domain cross-correlation of the cyclic prefix (CP). In light of this property, a new decision metric that measures the power of the data found on two minor diagonals in the covariance matrix related to the CP is introduced. The impact of synchronization errors on the signal detection is analyzed. Besides this, a likelihood-ratio test is proposed according to the Neyman-Pearson criterion after deriving probability distribution functions of the decision metric under hypotheses of signal presence and absence. A threshold, subject to the requirement of probability of false alarm, is derived; also the probabilities of detection and false alarm are computed accordingly. Finally, numerical simulations are conducted to demonstrate the effectiveness of the proposed algorithm.

A new analysis on timing jitters in APD receivers of optical communication systems when considering intersymbol interferences (APD를 사용하는 광통신 시스템 수신기에서 심벌간 간섭을 고려할 경우 타이밍 지터에 대한 새로운 해석)

  • 신요안;은수정;김부균
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.3
    • /
    • pp.539-546
    • /
    • 1997
  • In this paper, we proposed a new mehtod to analyze the performance degradation by timing jitters in the APD (avalanche photodiode) receivers of intensity modulation/direct detection digital optical communication systems where raised cosine pulse-shaping filters are used to reduce the effect of noise while minimizing intersymbol interferences. The proposed analytical method is an extension of an analytical method we have already developed for pin diode receivers, and incorporates the effects of APD's multiplication factor and resulting shot noise. Using the proposed analytical method, we derive an approximated power penalty due to timing jitters based on an assumption of Gaussian distribution for timing jitters, and compare with that of the conventional analytical method. The results obtained from the proposed analytical method show that conventional analytical methods underestimate the influence of timing jitters on the reciver performance. The results also show that APD's multiplication factor which optimizes receiver sensitivity is smaller than that obtained by the conventional analytical method.

  • PDF

A Distributed Coexistence Mitigation Scheme for IoT-Based Smart Medical Systems

  • Kim, BeomSeok
    • Journal of Information Processing Systems
    • /
    • v.13 no.6
    • /
    • pp.1602-1612
    • /
    • 2017
  • Since rapidly disseminating of Internet of Things (IoT) as the new communication paradigm, a number of studies for various applications is being carried out. Especially, interest in the smart medical system is rising. In the smart medical system, a number of medical devices are distributed in popular area such as station and medical center, and this high density of medical device distribution can cause serious performance degradation of communication, referred to as the coexistence problem. When coexistence problem occurs in smart medical system, reliable transmitting of patient's biological information may not be guaranteed and patient's life can be jeopardized. Therefore, coexistence problem in smart medical system should be resolved. In this paper, we propose a distributed coexistence mitigation scheme for IoT-based smart medical system which can dynamically avoid interference in coexistence situation and can guarantee reliable communication. To evaluate the performance of the proposed scheme, we perform extensive simulations by comparing with IEEE 802.15.4 MAC protocol which is a traditional low-power communication technology.

An Analysis on Regional Farm System - A Case of Kyung-Ju Area - (지역영농체계 분석 사례연구 - 경주지역을 중심으로 -)

  • Kim, Chung Sil
    • Current Research on Agriculture and Life Sciences
    • /
    • v.13
    • /
    • pp.71-83
    • /
    • 1995
  • The purposes of this study are to classify farm area and to develop farm system by region. The factor analysis was used as a main analysing tool to approach these purposes in this study. The farming of Kyung-Ju area in cropping sector is classified into 11 cropping systems. The distribution of specialized regions is very distinctive by the cropping systems. The specialized regions resulted from this analysis are different by factor. An efficient means to raise agricultural competitive power is to realize farm specialization by region according to productivity factor.

  • PDF

A SCADA Testbed Implementation Architecture for Security Assessment (SCADA 시스템의 보안성 평가를 위한 테스트베드 구성)

  • Lee, Jong-Joo;Kim, Seog-Joo;Kang, Dong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.50-56
    • /
    • 2010
  • Supervisory Control and Data Acquisition Systems (SCADAs) is real-time monitor and control systems. SCADA systems are used to monitor or control chemical and transportation processes, in municipal water supply systems, electric power generation, transmission and distribution, gas and oil pipelines, and other distributed processes. SCADA refers to a large-scale distributed system. The supervisory control system is placed on top of a real time control system to control external processes. Emerging security technologies and security devices are decreasing the vulnerability of the power system against cyber threats. Dealing with these threats and analyzing vulnerabilities is an important task for equipment such as RTU, IED and FEP. To reduce such risks, we develop such a SCADA testbed. This paper presents the development of a testbed designed to assess the vulnerabilities SCADA networks(including serial communication).

Analysis on Momentary Voltage Dips with the Interconnection Operation of Utility-interactive Cogneration Systems Considering Their Generator Type (발전기 형태를 고려한 열병합발전시스템의 배전계통 연계운전시의 순시전압변동 해석)

  • 최준호;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.23-30
    • /
    • 2000
  • Cogeneration systems are seen as a significant innovation for dispersed energy generation since they are both environmentally friendly and has comparatively high degrees of efficiency. It is especially suited for the decentralized provision of electricity and heat. However, it causes operational problems such as voltage regulation, voltage variation, protection and safety. Especially, it is expected that the interconnection/disconnection operation of cogeneration system has an effect on distribution voltage regulation and variation. Recently, with the increased use of customer-owned computers and other sensitive electronic equipment, electric power quality has become an important concerns. Therefore, the voltage quality problems with cogeneration system should be investigated because the voltage quality is an important part of electrical power quality. In this paper, the momentary voltage dips associated with the interconnection/disconnection operation of cogeneration system are analyzed, including restraint solutions at the customer level. In addition, the unit capacity of cogeneration systems per feeder are evaluated from the view point of momentary voltage variations. The results of this paper are useful analysis data for interconnection standards/guidelines of cogeneration systems and dispersed generation (DG)

  • PDF

Design and Implementation of UV Flame Detector Module Using Low Power Algorithm of ZigBee (ZigBee Protocol의 저 전력 알고리듬을 이용한 UV Flame Detector의 설계 및 구현)

  • Lee, Young-Jae;Chang, Choong-Won;Rhee, Sang-Yong;Jung, Min-Su
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.3
    • /
    • pp.429-436
    • /
    • 2008
  • Nowadays fires must be detected rapidly Abstract, and by connecting the detector's distribution, sender, transponder, receiver and others can be connected. Mechanical systems are implemented in today's buildings. However, this kind of constructing method has some disadvantages, that is, if fire happens somewhere, we cannot judge where the fires happen, and it is also difficult to judge what extent the fires reach. In order to overcome the disadvantages, in this paper, according to the tendency of combining the Ubiquitous and Intelligent Network, we propose a type of system by using the method of comparing the differences of the existed systems. The proposed system is designed to perceive the fires rapidly and confirm the fire place and fire scale correctly.